![Rockwell Automation Allen-Bradley 1443 Series Technical Data Manual Download Page 32](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-1443-series/allen-bradley-1443-series_technical-data-manual_1475673032.webp)
32
Rockwell Automation Publication 1443-TD001D-EN-P - March 2019
1443 Series Accelerometers Specifications
1443-ACC-VO-S Accelerometer
Table 16 - 1443-ACC-VO-S Accelerometer Specifications
Attribute
Value
Performance
Sensitivity (±5%)
(1)
(1) Sensitivity tolerance is across the operating temperature range. Conversion factor 1 g = 9.81 m/s
2
.
4 mV/(mm/s)
100 mV/(in/s)
Output
±1.27 m/s
±50 in/s
Measurement range Peak
±1000 mm/s
±39.4 in/s
Frequency range (±10%)
(2)
(2) 1 Hz = 60 cpm (cycles per minute).
3.5…4 kHz
210…240,000 cpm
Frequency range (±3 dB)
2…6 kHz
120…360,000 cpm
Resonant frequency, typical
22 kHz
1320 kcpm
Broadband resolution (1…10,000 Hz), typical
11.4
μ
m/s
450
μ
in./s
Non-linearity
(3)
(3) Zero-based, least-squares, straight-line method.
±1%
±1%
Transverse sensitivity
< 5%
< 5%
Environmental
Overload limit (shock)
49,050 m/s
2
pk
5000 g pk
Temperature range
-55…+140 °C
-67…+284 °F
Enclosure rating
IP66 to 68, depending upon the cable assembly used.
IP66 to 68, depending upon the cable assembly used.
Electrical
Settling time (within 1% of bias)
< 2.0 s
< 2.0 s
Discharge time constant
≥ 0.5 s
≥ 0.5 s
Excitation voltage
18…28 V DC
18…28 V DC
Constant current excitation
2...10 mA
2...10 mA
Output impedance
<200 Ω
<200 Ω
Output bias voltage
10…12 V DC
10…12 V DC
Electrical isolation (case)
> 10
8
Ω
> 10
8
Ω
Electrical protection
500V
500V
Physical
Size (hex x height)
25 x 35 x 30 mm
1 x 1.4 x 1.2 in
Weight, approx.
170 g
6.0 oz
Mounting thread
(4)
(4) 1/4-28 UNF has no equivalent in metric units.
M6 x 1 mm male
1/4-28 UNF male
Mounting torque
8 N•m
6 ft•lb
Sensing element
Ceramic
Sensing geometry
Compression
Housing material
Stainless Steel
Sealing
Welded hermetic
Electrical connector
Two-pin MIL-C-5015
Electrical connector position
Side
Supplied Accessories
(5)
(5) ICS-3 3 pt calibration 10 Hz, 100 Hz, 1 kHz.
1443-BLT-125-0
1443-BLT-125-M6
ICS-3 3 pt calibration