XM Dynamic Measurement Module Terminal Base
19
Publication
ICM-IN003D-EN-P - March 2013
Non-operating temperature
IEC 60068-2-1 (Test Ab, Unpackaged
Non-operating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged
Non-operating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged
Non-operating Thermal Shock):
-40…85 °C (-40…185 °F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Damp
Heat):
5…95% noncondensing
Vibration
IEC 60068-2-6 (Test Fc, Operating):
5 g @ 10…500 Hz
Operating shock
IEC 60068-2-27 (Test Ea, Unpackaged Shock):
15 g
Nonoperating shock
IEC 60068-2-27 (Test Ea, Unpackaged Shock):
20 g
Emissions
CISPR 11 (IEC 61000-6-4):
Class A
ESD Immunity
IEC 61000-4-2:
6 kV contact discharges
8 kV air discharges
Radiated RF Immunity
IEC 61000-4-3:
10V/m with 1 kHz sine-wave 80% AM
from 80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM
at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM
at 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from
2000…2700 MHz
EFT/B Immunity
IEC 61000-4-4:
±4 kV at 5 kHz on power ports
±2 kV at 5 kHz on signal and shielded ports
Environmental Specifications
Attribute
Value