Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
55
Chapter 5 System Configuration
…
describe the switch functions and
default settings for the receiver plug-ins.
450L-APR-ON-5 Connection
Plug-in
450L-APR-ED-8 Connection
Plug-in
shows the function and default settings for the M12 8-pin EDM
receiver plug-in (450L-APR-ED-8) that is inserted in a 450L safety light curtain
transceiver stick (450L-APR-BL-5) connection plug-in.
Table 23 - Function and Default Settings
Switch Number
Switch Function
Default
Description
1
450L-E only: Software
Configuration
OFF
OFF: Disabled
ON: Enabled
2
Low Range Activation
OFF
OFF: Disabled
ON: Enabled
3
450L-E and 450L PAC only:
Activates Beam Coding
OFF
OFF: Disabled
ON: Enabled
4
450L-E only: Activates
Interference Rejection
OFF
OFF: Disabled
ON: Enabled
Table 24 - Function and Default Settings
Switch Number
Switch Function
Default
Description
1
450L-E only: Software
Configuration
OFF
OFF: Disabled
ON: Enabled
2
Low Range Activation
OFF
OFF: Disabled
ON: Enabled
3
450L-E and 450L PAC only:
Activates Beam Coding
OFF
OFF: Disabled
ON: Enabled
4
450L-E only: Activates
Interference Rejection
OFF
OFF: Disabled
ON: Enabled
5
Combination activates the
following start modes:
• Automatic start
• Manual (re) start
• Manual cold start
• Manual start with off
function
OFF
• DIP 5: OFF, DIP 6: OFF:
Automatic start (Default)
• DIP 5: ON, DIP 6: OFF:
Manual (re) start
• DIP 5: OFF, DIP 6: ON:
Manual cold start
• DIP 5: ON, DIP 6: ON:
Manual start with off
function
6
OFF
7
External Device Monitoring OFF
OFF: Disabled
ON: Enabled
8
—
OFF
—