Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
131
Chapter 9 Connected Components Workbench Software
Figure 112 - Example Schematic for Two Sensor Muting
In the hardware setup, which is shown in
Bulletin 450L-APR-MU-8, as the Connection plug-in Rx. On the plug-in, set
switch 1 to ON, and all other switches are OFF. This step allows the Connected
Components Workbench software to configure the muting setup.
Figure 113 - Hardware Setup
Muting Type and Settings
In
, select the Muting Type. Since the receiver only has
the muting plug-in, the muting types are limited to two sensors. Select the type
of muting. Click Settings to adjust the muting time parameters.
450L-E4FN1200YD
450L-E4FN1200YD
S11 S12 S21 S22 S34 A1
13
L11 A2
14 23 24 Y32
SI
440R-S12R2
0
MM
AM
42EF-P2MPB-F4
889D-
F4AC-5
889D-
F4AC-5
42EF-P2MPB-F4
450L-APT-PW-5
898D-F5NC-5
450L-APR-MU-8
898D-F8NB-5
Tx
Rx
FE
FE
+24V DC
24V Com (0V)
L
L
+
+
N
N
1606-XLP95E
24-
28V
DC ok
120-240V AC
PE
Primary Protective Earth Ground
Muting Sensor 1
Muting Sensor 2
Mute
Dependent
Override
RESET
RESET
1 Brown
2 White (Not Used)
4 Black (Not Used)
3 Blue
5 Gray
2 Brown
8 Red
1 White
4 Yellow
5 Gray OSSD1
6 Pink OSSD2
7 Blue
3 Green
Brown
Black
Blue
White (Not Used)
Brown
Black
Blue
White (Not Used)