10

1204 Terminator

Maintenance

The terminator does not require routine maintenance. However, you
should periodically remove dust to allow for maximum cooling
efficiency.

!

ATTENTION: Electric shock can cause injury or death.
Remove all power before touching the terminator.

!

ATTENTION: The terminator surfaces may be hot enough
to cause serious burns. Allow the terminator time to cool
down before touching any surface.

Summary of Contents for Allen-Bradley 1204 Series

Page 1: ...g connecting and grounding procedures are included Major topics and page numbers are listed below Catalog Number Description 1 Dimensions Weights and Cable Locations 2 Specifications 3 Heat Dissipation 3 Determining the Maximum Cable Length for Your System 4 Installation 7 Drive Programming 9 Grounding 9 Maintenance 10 Catalog Number Description The following table provides information about the c...

Page 2: ...5 117 9 4 64 BOTTOM SIDE FRONT Out Going Cable 4 Slots for M4 Hardware DANGER CAN CAUSE SHOCK BURNS OR DEATH DISCONNECT AND LOCKOUT ALL POWER SOURCES BEFORE SERVICING SURFACES MAY BE HOT ALLOW TO COOL BEFORE SERVICING Bulletin 1204 TFB2 Series A AC Drive HP 5 to 600 Voltage 380 600 VAC Carrier Freq 2 KHz Made in U S A See Instruction Manual For Mounting Instructions Allen Bradley Motor Terminator ...

Page 3: ...t contain hazardous volatile dust vapor gas or liquid Heat dissipation1 Refer to the heat dissipation table below Enclosure type IP65 NEMA Type 4x Agency certification U L C UL Altitude derating Full rating 0 1000 meters 0 3280 feet Ambient Temperature Limit Altitude m ft 40 30 35 0 4 000 13 200 3 000 9 900 2 000 6 600 1 000 3 300 degrees C Drive Frequency Length meters feet 1204 TFA1 Terminator 1...

Page 4: ...n Bradley drives Each motor is energy efficient and designed to meet or exceed the requirements of the Federal Energy Act of 1992 All 1329R L motors are optimized for variable speed operation and include premium inverter grade insulation systems which meet or exceed NEMA MG1 Part 31 40 4 2 Drive HP 460V Motor HP 460V w 1204 TFB2 Terminator w 1204 TFA1 Terminator With Allen Bradley 1329R L Motors M...

Page 5: ...ld Shld 2 Unshld Shld 2 Unshld A1 0 37 0 5 0 37 0 5 Use 1204 TFA1 Terminator or 1329R L Motor 30 5 100 61 0 200 30 5 100 61 0 200 For applications installations using new motors no restric tions in lead length due to volt age reflection are necessary You should observe standard practices for voltage drop cable capacitance and other issues 0 75 1 0 75 1 30 5 100 30 5 100 30 5 100 30 5 100 0 75 1 0 ...

Page 6: ...1329R L A B Any Cable Any Cable Any Cable Any Cable Any Cable Any Cable A4 0 75 1 0 75 1 NR 182 9 600 335 3 1100 NR 61 0 200 182 9 600 0 37 0 5 NR 182 9 600 335 3 1100 NR 61 0 200 182 9 600 1 5 2 1 5 2 NR 182 9 600 335 3 1100 NR 61 0 200 182 9 600 1 2 1 5 NR 182 9 600 335 3 1100 NR 61 0 200 182 9 600 0 75 1 NR 182 9 600 335 3 1100 NR 61 0 200 182 9 600 0 37 0 5 NR 182 9 600 335 3 1100 NR 61 0 200 ...

Page 7: ...USE SHOCK BURNS OR DEATH DISCONNECT AND LOCKOUT ALL POWER SOURCES BEFORE SERVICING SURFACES MAY BE HOT ALLOW TO COOL BEFORE SERVICING Bulletin 1204 TFB2 Series A AC Drive HP 5 to 600 Voltage 380 600 VAC Carrier Freq 2 KHz Made in U S A See Instruction Manual For Mounting Instructions Allen Bradley Motor Terminator Q E T N O C D N I X 6 6 9 D E T S I L Q E T N O C D N I X 6 6 9 D E T S I L DANGER C...

Page 8: ...in 1204 TFB2 Series A AC Drive HP 5 to 600 Voltage 380 600 VAC Carrier Freq 2 KHz Made in U S A See Instruction Manual For Mounting Instructions Allen Bradley Motor Terminator Q E T N O C D N I X 6 6 9 D E T S I L Q E T N O C D N I X 6 6 9 D E T S I L 152 4 mm 6 0 in 152 4 mm 6 0 in 304 8 mm 12 0 in 304 8 mm 12 0 in 152 4 mm 6 0 in 152 4 mm 6 0 in 152 4 mm 6 0 in ATTENTION Theterminatorsurfacesmay...

Page 9: ...on Mode Core Conduit 4 Wire Cable To Computer Position Controller for TE shield ground see Control and Signal Wiring Ground per Local Codes Motor Frame Motor Frame Motor Terminator PE V T2 W T3 PE Gnd Options that can be installed as needed Nearest Building Structure Steel DANGER CAN CAUSE SHOCK BURNS OR DEATH DISCONNECT AND LOCKOUT ALL POWER SOURCES BEFORE SERVICING SURFACES MAY BE HOT ALLOW TO C...

Page 10: ...d periodically remove dust to allow for maximum cooling efficiency ATTENTION Electric shock can cause injury or death Remove all power before touching the terminator ATTENTION Theterminatorsurfacesmaybehotenough to cause serious burns Allow the terminator time to cool down before touching any surface ...

Page 11: ...1204 Terminator 11 Notes ...

Page 12: ...and France Germany Ghana Greece Guatemala Honduras Hong Kong Hungary Iceland India Indonesia Iran Ireland Israel Italy Jamaica Japan Jordan Korea Kuwait Lebanon Macau Malaysia Malta Mexico Morocco The Netherlands New Zealand Nigeria Norway Oman Pakistan Panama Peru Philippines Poland Portugal Puerto Rico Qatar Romania Russia Saudi Arabia Singapore Slovakia Slovenia South Africa Republic of Spain S...

Reviews: