background image

Installation Instructions

Original Instructions

GuardLogix 5580 Controllers

The GuardLogix® 5580 controllers help enable faster system performance, capacity, productivity, and security to help meet the growing demands of smart machines and 
equipment for manufacturing.

Integrated Motion over EtherNet/IP

TM

 for up to 256 axes. 

1 Gb embedded Ethernet port enables high performance, communications, I/O, and motion control.

Secure Digital (SD) card provides optional nonvolatile memory to store user program and tag data on the controller.

Studio 5000 Automation Engineering & Design Environment® provides ease of system design and commissioning.

Digitally signed and encrypted firmware helps protect against malicious intent.

FactoryTalk® Security provides centralized authentication and access control by verifying the identity of each user-access attempt to the system.

Display provides enhanced diagnostics and troubleshooting.

The GuardLogix controller is made up of a primary controller and a safety partner, for SIL 3 applications, that function together in a 1oo2 architecture. With a safety partner 
installed, GuardLogix controllers are:

Type-approved and certified for use in safety applications up to and including SIL 3 per IEC 61508.

EC Type-approved for use in safety applications up to and including SIL CL3 per IEC 62061.

EC Type-approved for use in safety applications up to and including Performance Level PLe (Category 4) per ISO 13849-1. When used without a safety partner 

installed, SIL CL2 and PLd (Category 3) are achievable.

Summary of Changes

This manual contains new and updated information as indicated in the following table.

Catalog Numbers 1756-L81ES, 1756-L81ESK, 1756-L82ES, 1756-L82ESK, 1756-L83ES, 1756-L83ESK, 1756-L84ES, 1756-L84ESK, 

1756-L8SP, 1756-L8SPK

Topic Page

Product Advisories

3

Parts List

4

Required System Components

5

Product Dimensions

5

Connectors and Status Indicators

6

Install the Controller

6

Install the SD Card

7

Connect to an EtherNet/IP Network

7

Confirm Installation

7

Specifications

8

Additional Resources

9

Topic 

Page

Added Plug Attention Statement

6

Specifications

8

Summary of Contents for 1756-L81ES

Page 1: ...de up of a primary controller and a safety partner for SIL 3 applications that function together in a 1oo2 architecture With a safety partner installed GuardLogix controllers are Type approved and certified for use in safety applications up to and including SIL 3 per IEC 61508 EC Type approved for use in safety applications up to and including SIL CL3 per IEC 62061 EC Type approved for use in safe...

Page 2: ...nnes formées selon le code de pratique en vigueur Si cet équipement est utilisé d une façon qui n a pas été définie par le fabricant la protection fournie par l équipement peut être compromise ATTENZIONE Prima di installare configurare ed utilizzare il prodotto o effettuare interventi di manutenzione su di esso leggere il presente documento ed i documenti elencati nella sezione Altre risorse rigua...

Page 3: ...le code de température pour les environnements dangereux Lorsque plusieurs produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l install...

Page 4: ...permanent connection Do not use the USB port in hazardous locations Environment and Enclosure ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications as defined in EN 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is not intended for use in residential environments and may not provide adequate pr...

Page 5: ...C and series B 1756 A4 1756 A4K 1756 A7 1756 A7K 1756 A10 1756 A10K 1756 A13 1756 A13K 1756 A17 1756 A17 K Power supply standard 1756 PA72 1756 PA72K 1756 PA75 1756 PA75K 1756 PB72 1756 PB72K 1756 PB75 1756 PB75K 1756 PH75 1756 PC75 Power supply redundant 1756 PA75R 1756 PA75RK 1756 PB75R 1756 PB75RK 1756 PSCA2 1756 PSCA2K 139 6 mm 5 50 in 34 55 mm 1 360 in 145 2 mm 5 717 in Front view GuardLogix ...

Page 6: ...ion you can use a Series B chassis derating to 50 C 122 F or Series C chassis with no restrictions WARNING When you insert or remove the module while backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Repeated electrical arcing causes excessive wear to contac...

Page 7: ...therNet IP network then connect an RJ45 cable to the Ethernet port on the controller Confirm Installation After you insert the controller into the chassis and apply power the 4 character display and status indicators provide information about the controller See the ControlLogix 5580 and GuardLogix 5580 Controllers User Manual publication 1756 UM543 for information on how to interpret the 4 charact...

Page 8: ... Ta 60 C 32 F Ta 140 F for Series C Chassis Note If operating above 55 C 131 F modules greater than 6 2W shall not be installed in slots adjacent to the controller Temperature operating SIL 3 PLe IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 0 C Ta 60 C 32 F Ta 140 F for Series C Chassis 0 C Ta 50 C 32 F Ta 122 F for Se...

Page 9: ...ollers User Manual publication 1756 UM543 Provides information on how to configure select I O modules manage communication develop applications and troubleshoot the ControlLogix 5580 controllers GuardLogix 5580 and Compact GuardLogix 5380 Controller Systems Safety Reference Manual publication 1756 RM012 Provides information on safety application requirements for GuardLogix 5580 and Compact GuardLo...

Page 10: ...10 Rockwell Automation Publication 1756 IN048D EN P March 2021 GuardLogix 5580 Controllers Installation Instructions Notes ...

Page 11: ...Rockwell Automation Publication 1756 IN048D EN P March 2021 11 GuardLogix 5580 Controllers Installation Instructions Notes ...

Page 12: ...lectrical and Electronic Equipment WEEE Rockwell Automation maintains current product environmental compliance information on its website at rok auto pec At the end of life this equipment should be collected separately from any unsorted municipal waste Rockwell Automation Support Use these resources to access support information Documentation Feedback Your comments help us serve your documentation...