    DeviceNet ArmorBlock Network and Auxiliary Powered Module, Series A 

Publication

 1732D-IN011A-EN-E - April 2009

Interpret the Status Indicators

This module has the following status indicators:

Network and Module status indicators for DeviceNet

Auxiliary Power indicator

Individual I/O status indicators for inputs and outputs

                           

I - 0

I - 1

I - 2

I - 3

I - 4

I - 5

I - 6

I - 7

O - 0

O - 1

O - 2

O - 3

O - 4

O - 5

O - 6

O - 7

X10

X1

2

4

8

6

6

0

0

8

2

4

P

W

R

DNet In

DNet Out

NET

MOD

44763

Input status 

indicators

Module status 

indicator

Network status 
indicator

Output status 
indicators

Auxiliary power 
status  indicator

Summary of Contents for 1732D-8X81212HD

Page 1: ...Number 1732D 8X81212HD Topic Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic Discharge 3 About the Module 4 Catalog Number Explanation 5 Install the Module 5 Mount...

Page 2: ...cular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with re...

Page 3: ...n Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings beyond what this product provides that are required to comply with certain produc...

Page 4: ...e sealed M12 style The DeviceNet network uses advanced network technology producer consumer communication to increase network functionality and throughput Visit our web site at http www ab com network...

Page 5: ...ule Connect the cord sets Set the Node Address Valid node addresses are 00 through 63 Set the node address using either the rotary switches RSNetWorx for DeviceNet DeviceNetManager or another software...

Page 6: ...indicated by a flashing red MOD LED Settings of 64 through 99 cause the module to use the last valid node address stored internally For example the last setting internally was 40 If a change is made t...

Page 7: ...ions Refer to the mounting dimensions illustration to help you mount the module Module Dimensions I 0 I 1 I 2 I 3 I 4 I 5 I 6 I 7 O 0 O 1 O 2 O 3 O 4 O 5 O 6 O 7 X10 X1 2 4 8 6 6 0 0 8 2 4 P W R NET M...

Page 8: ...and a lock washer to mount the module Mount the flat and the lock washer as shown in the mounting illustration Torque the mounting screws to 0 64 Nm 6 in lb Connect the I O Cord Sets to the ArmorBlock...

Page 9: ...e pinout diagrams for the I O connectors M12 style 5 pin Female Input Connectors M12 style 5 pin Female Output Connector Male Female View into Connector Pin 1 Drain Pin 2 V Red Pin 3 V Black Pin 4 CAN...

Page 10: ...ny I O devices connected to this equipment require Class 2 power to operate this equipment and all connected I O must be powered by a Class 2 source To comply with the CE Low Voltage Directive LVD thi...

Page 11: ...State productions occur when an input changes or a fault condition occurs If no input or fault condition change occurs within the expected packet rate a heartbeat production occurs This heartbeat pro...

Page 12: ...Network and Module status indicators for DeviceNet Auxiliary Power indicator Individual I O status indicators for inputs and outputs I 0 I 1 I 2 I 3 I 4 I 5 I 6 I 7 O 0 O 1 O 2 O 3 O 4 O 5 O 6 O 7 X10...

Page 13: ...ting normally and is online with connections in the established state As a Group 2 module it means that the module is allocated to a master None Flashing Green Device is online with no connections in...

Page 14: ...put short circuit Check your input devices and check your output devices and cycle power Red Critical fault device timed out or has an unrecoverable fault Cycle power to the device If that does not fi...

Page 15: ...Number of inputs 8 Off state input voltage max 5V DC On state input voltage max 25V DC On state input voltage nom 24V DC On state input voltage min 11V DC Sensor source voltage max 25V DC Sensor sour...

Page 16: ...C On state output current max 1 4 A Current per module max 8 A all outputs Off state output leakage current max 50 A Surge current per output max 3 2 A for 10 ms repeatable every 2 s General Specifica...

Page 17: ...Pilot duty rating Not rated Enclosure type rating Meets IP65 66 67 69K when marked and NEMA 4X 6P with receptacle dust caps or cable termination Wiring category 1 1 on signal ports 1 on power ports 2...

Page 18: ...14 Test Na Unpackaged Non operating Thermal Shock 45 85 C 49 185 F Relative humidity IEC 60068 2 30 Test Db Unpackaged Damp Heat 5 95 non condensing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 5...

Page 19: ...nal ports 2 kV at 5 kHz on communications ports Surge transient immunity IEC 61000 4 5 1 kV line line DM and 2 kV line earth CM on power ports 1 kV line line DM and 2 kV line earth CM on signal ports...

Page 20: ...08 EC EMC Directive compliant with EN 61326 1 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clause 8 Z...

Page 21: ...DeviceNet ArmorBlock Network and Auxiliary Powered Module Series A 21 Publication 1732D IN011A EN E April 2009 Notes...

Page 22: ...22 DeviceNet ArmorBlock Network and Auxiliary Powered Module Series A Publication 1732D IN011A EN E April 2009 Notes...

Page 23: ...DeviceNet ArmorBlock Network and Auxiliary Powered Module Series A 23 Publication 1732D IN011A EN E April 2009 Notes...

Page 24: ...s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running New Product Satisfaction Return Rockwell Automation tests all...

Reviews: