28
Rockwell Automation Publication 1441-UM006A-EN-P - May 2011
Chapter 2
Run Up/Coast Down Extension Module
Displaying Measurements
in Table Format
The magnitude and phase of selected orders at the varied rpm speeds are
displayed in a table.
Set Up the Table
1.
Select Table on the RUCD - Display Select screen and press F3 (Display).
The RUCD - Table Setup screen appears.
2.
Select a parameter press the Right arrow to open a list of values.
3.
Select or type in a parameter value.
4.
Press the Left arrow to save your selection.
Use the descriptions in
Table Parameter Descriptions on page 28
to help
you configure the parameters.
5.
When you are finished, press F4 (Display) to display the table.
Table 6 - Table Parameter Descriptions
Parameter Name
Description
Values/Comments
Start Spd (RPM)
Sets the start speed of the recorded data for the table.
This defaults to the Start Spd value set in the RUCD Setup screen.
Run Up/Coast Down Setup Parameters on page 18
.
10…3600 rpm
Stop Spd (RPM)
Sets the stop speed of the recorded data for the table.
This defaults to the Stop Spd value set in the RUCD Setup screen.
Run Up/Coast Down Setup Parameters on page 18
.
10…3600 rpm