background image

3

OPERATING PRECAUTIONS

NOTE: IT IS VERY IMPORTANT THAT YOU READ THIS SECTION TO
PROVIDE YEARS OF TROUBLE FREE USE. THIS UNIT REQUIRES CAREFUL
HANDLING.

All warnings on this equipment and in the operating instructions should be adhered
to and all operating instructions should be followed.
Do not use this equipment near water. Care should be taken so that objects do
not fall and liquids are not spilled into the unit through any openings.
The power cord should be unplugged from the outlet when left unused for a long
period of time.

DO NOT ATTEMPT TO SERVICE THIS EQUIPMENT. THIS EQUIPMENT
SHOULD BE SERVICED BY QUALIFIED PERSONNEL ONLY. DO NOT MAKE
ANY INTERNAL ADJUSTMENTS OR ADDITIONS TO THIS EQUIPMENT AT
ANY TIME. DO NOT TAMPER WITH INTERNAL ELECTRONIC
COMPONENTS AT ANY TIME.  FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY VOID THE WARRANTY OF THIS EQUIPMENT, AS
WELL AS CAUSING SHOCK HAZARD.

POWER REQUIREMENTS

This unit accepts power from the 9VAC/1.5A adaptor supplied with the unit.
This 9 volt RMS AC voltage is internally processed by a voltage doubler which
generates a bipolar ±15 volts to maintain the headroom and sound quality of
professional, studio quality equipment. Using an external power source such as
this minimizes excessive noise and hum problems often associated with internal
transformers, providing optimal performance for the user.

OPERATING TEMPERATURE

Do not expose this unit to excessive heat. This unit is designed to operate between
32° F and 104° F (0° C and 40° C). This unit may not function properly under
extreme temperatures.

Introduction

Congratulations on your purchase of the Rocktron HUSH

®

 Super C!

Designed for guitar applications, the Super C utilizes the latest in our HUSH noise

reduction technology combined with the latest V.I.R. (Variable Integrated Release)
circuitry configured as a noise gate. This combination provides extremely effective noise
reduction while playing and complete silence when not.

Although the Super C is a stereo noise reduction system, a single HUSH Threshold

and Gate Threshold are used to control both channels.

This manual will introduce you to the various features and functions of the Super C.

Please keep it for future reference.

3

Summary of Contents for HUSH Super C

Page 1: ...1 ...

Page 2: ...tic Compatibility Standard s EN55013 EN50082 1 This means that this product has been designed to meet stringent guidelines on how much RF energy it can emit and that it should be immune from other sources of interference when properly used Improper use of this equipment could result in increased RF emissions which may or may not interfere with other electronic products To insure against this possi...

Page 3: ...t RMS AC voltage is internally processed by a voltage doubler which generates a bipolar 15 volts to maintain the headroom and sound quality of professional studio quality equipment Using an external power source such as this minimizes excessive noise and hum problems often associated with internal transformers providing optimal performance for the user OPERATINGTEMPERATURE Do not expose this unit ...

Page 4: ...hold control thus activating the gate and providing additional downward expansion IN OUT switch and LED This switch allows for the Super C to be bypassed when noise reduction is not required When lit the LED indicates that the Super C is currently active in the signal path REFswitch This switch determines the sensitivity of the Super C When using the Super C with professionalaudioequipmentprovidin...

Page 5: ...must be used CH A CH B OUT jacks These mono jacks provide outputs from the CH A and CH B channels of the Super C Note When CH A is used as a single signal source the signal will be present in both the CH A and CH B outputs POWER jack This 2 5mm pin jack accepts power from the 9VAC adapter supplied with the unit Super C Rear Panel 1 2 3 ...

Page 6: ...6 System Connections MonoApplications 6 ...

Page 7: ...7 StereoApplications ...

Page 8: ...8 Combo Amp Connection ...

Page 9: ...9 Amplifier Head Connection ...

Page 10: ...10 Bass Combo Connection ...

Page 11: ...11 Bass Head Connection ...

Page 12: ...elf allowing the unit to be used as strictly a downward expander HUSH Section Rocktron s patented HUSH noise reduction is a single ended system that combines the principles of dynamic filtering and low level downward expansion Dynamic Filtering Dynamic filtering is achieved by dynamically controlling a low pass filter to open and close the bandwidth of the output signal depending upon the amount o...

Page 13: ...ic filter will open fully to pass the signal and eliminate the possibility of a loss of high end frequency response Downward Expansion The second half of the HUSH process incorporates downward expansion The low level expander of the HUSH system operates like an electronic volume control The HUSH system utilizes a voltage controlled amplifier VCA circuit which can control the gain between the input...

Page 14: ...if at all and the noise floor will remain audible Gate Section The other half of the Super C consists of a noise gate A noise gate completely shuts off the output signal when the input signal level drops below a prescribed threshold level volume On the Super C this threshold is determined by the Gate Threshold control on the front panel This control should be set so that it doesn t cut notes off i...

Page 15: ...n Pedal RMM900 7 pin Din MIDI Cable RM4 MIDI Controller for Vendetta amps RFS1 and RFS2 Single and Double Latching Footswitches for Rampage Amps RackGear Gainiac 2 preamp w 12ax7 tube Xpression multi effects processor Blue Thunder bass preamp w multi effects Voodu Valve preamp w 12ax7 tube and multi effects Prophesy our top of the line preamp with multi effects HUSH Super C guitar noise silencing ...

Page 16: ... Rocktron A Division of GHS Corporation 2813 Wilber Avenue Battle Creek MI 49015 USA Rocktron Phone 1 269 968 3351 Email info rocktron com Check us out on the web at www rocktron com 2005 0001 Rev 4 01 05 ...