Rocker BioVac 225 Instruction Manual Download Page 2

A.  Unpacking 

 

When unpacking, notice if the Bio-Suction System is in good situation. If not, please contact the distributor or   

contact us by e-mail: 

[email protected] 

immediately for assistance. 

 

Model 

BioVac 225

 

BioVac 225 Plus

 

BioVac 225 - BioDolphin

 

Standard 

Package 

Includes: 

 

BioVac 225 suction unit 

Suction bottle 

Disc filter (PTFE) 

Tube connecting adaptor 

2m Silicone tube 

1-channel tip adaptor (150 

mm) 

Instruction manual 

x1 

x1 

x1 

x1 

x1 

x1 

 

x1 

BioVac 225 suction unit 

Suction bottle 

Disc filter (PTFE) 

Tube connecting adaptor   

2m Silicone tube 

Handle 

8 channel tip adaptor with 

ejector 

1 channel tip adaptor with 

ejector 

1-channel tip adaptor (150 

mm) 

Repair kit of handle 

Instruction manual 

x1 

x1 

x1 

x1 

x1 

x1 

x1 

 

x1 

 

x1 

 

x1 

x1 

BioVac 225 suction unit 

Suction bottle   

Disc filter (PTFE) 

Tube connecting adaptor   

2m Silicone tube 

1 channel tip adaptor 

1 channel S.S. adaptor 

(40mm) 

BioDolphin Suction Kit 

Instruction manual 

x1 

x1 

x1 

x1 

x1 

x1 

x1 

 

x1 

x1 

 

B.  Important Notice 

 

 

Before using the instrument, please ensure that the power supply voltage matches the voltage rating for 

the instrument.   

 

Please ensure that all connections are well-sealed.   

 

The disc filter needs to be replaced periodically or immediately once it is contaminated or saturated. 

 

The built-in thermal protector will shut down the instrument automatically when it gets too hot. 

 

Please check the fuse, if the instrument doesn't work and the switch light doesn't light up after powered 

on. 

 

Do not use the instrument with organic or corrosive gases as it is not a chemical resistant product. 

 

Install the instrument in a clean, dust-less and ventilated area under 40

.

 

 

Pour some water into the suction bottle before use for easy cleaning after use. Clean the suction bottle 

with only tap water instead of any chemical detergents to prevent corrosion. 

 

It is always recommended to pour out waste solution in the suction bottle upon reaching 2/3 of the full 

level to prevent overflowing into the pump. 

 

Avoid letting the instrument fall down to prevent the damage. If you have any problems in the instrument, 

please contact your local distributor for assistance immediately. 

Summary of Contents for BioVac 225

Page 1: ...BioVac 225 BioVac 225 Plus BioVac 225 BioDolphin Portable suction system ...

Page 2: ...ce Before using the instrument please ensure that the power supply voltage matches the voltage rating for the instrument Please ensure that all connections are well sealed The disc filter needs to be replaced periodically or immediately once it is contaminated or saturated The built in thermal protector will shut down the instrument automatically when it gets too hot Please check the fuse if the i...

Page 3: ...C Portable Suction System Diagram pic 1 BioVac 225 pic 2 BioVac 225 Plus pic 3 BioVac 225 BioDolphin ...

Page 4: ...5 BioDolphin Item Description 1 BioVac 225 suction unit 2 Disc filter 3 Suction bottle 4 Tube connection adaptor 5 2m silicone tube 6 Handle 7 1 channel tip adaptor with ejector 8 8 channel tip adaptor with ejector 9 1 channel tip adaptor 150 mm 10 Repair kit of handle Item Description 1 BioVac 225 suction unit 2 Disc filter 3 Suction bottle 4 Tube connection adaptor 5 2m silicone tube 6 BioDolphi...

Page 5: ...use 3 On Off switch 4 Vacuum indicator 5 Vacuum regulator 6 Vacuum pump inlet 7 Suction bottle outlet 8 Suction bottle inlet pic 7 BioVac 225 suction unit and suction bottle part list pic 8 Overflow protection Item Description 1 Overflow protection ...

Page 6: ...ton 4 Handle end pic 9 Handle part list pic 10 Handle Disassembly pic 11 Operating of 8 channel tip adaptor with ejector pic 12 Change different tip adaptor item Description 1 Rubber adaptor 2 O ring AS004 3 O ring P7 4 Rubber valve 5 S S spring 6 O ring AS012 ...

Page 7: ...ance with the applicable regulations h Proceed with cleaning and maintenance after every use Note Check the liquid level of the waste bottle before each use and then empty it as per the applicable regulations 2 BioVac 225 Plus pic 2 a Ensure that the overflow protection is installed properly then place the suction bottle on the holder Please refer to pic 9 when installing it Note please always put...

Page 8: ...mm can be plugged into handle directly for waste suction of microplate or culture dish by pressing the suction button or pressing lock button to keep a continuous operation f The 1 channel tip adaptor is recommended to be plugged into the handle then have it connect with 200 µl disposable tip with which to prevent cross contamination in common microplate and culture dish g For 96 well microplate E...

Page 9: ...are consumables please replace at least every half year to ensure sufficient air flow G Troubleshooting Symptoms Possible causes and Solution Device fails to start 1 Check the power supply conform to power specified on main unit 2 Blown fuse replace fuse if it is burnt out 3 Check if the power switch is in the ON position 4 Vacuum still exists in system release vacuum and restart 5 Defective switc...

Page 10: ...lue 199120 00 BioDolphin P Suction kit pink 199130 00 BioDolphin G Suction kit green 199100 30 Handle 199100 46 1 channel tip adaptor 199100 47 1 channel S S adaptor 40 mm 199100 48 1 channel S S adaptor 80 mm 199100 49 8 channel S S adaptor 40 mm 199100 50 8 channel tip adaptor with ejector 199100 75 1 channel tip adaptor with ejector 199100 76 1 channel tip adaptor 150 mm 199100 61 Rack 199100 5...