properly due to environmental factors such as dust, dirt, oil, chemicals etc.

4.3 Climbing with Rope Grab

* To ascend with a F-5 Rope grab climb up the ladder normally. The 

detachable rope grab will follow the user.

* Use caution when climbing. Avoid carrying tools or equipment that do not 

allow your hands to be free for climbing. Ensure that the carried items are 

secured to avoid dropping on climbers below.

* Climb within your ability. Long climbs may require several rest breaks 

during ascent or descent to avoid exhaustion.

* Avoid climbing in high winds or severe weather conditions whenever possible.

* To descend, climb down properly in a normal position.

* Allow the detachable rope grab to lead the user down.

* Climbing down out of position (leaning back excessively) will cause the 

detachable rope grab to lock on the cable. If the detachable rope grab locks, 

move upward slightly to release, then continue down the ladder.

* When climbing is completed and the user is in a safe location remove the 

carabiner from rope grab and remove the rope grab from the lifeline.

4.4 Fall Clearance

* For equipment intended to use in fall arrest systems, it is essential for 

safety to verify the free space required beneath the user at the workplace 

before each occasion of use, so that, in the case of a fall, there will be no 

collision with the ground or the other obstacle in the fall path.

* A minimum 2-meter of fall clearance is required between the user’s 

feet and surface below. The user may not be protected against hitting 

the  ground  or  landing  during  the  first  2  meters  of  ascent  or  2  meters  of 

descent.

(Figure-2)

 * Use proper climbing procedures (e.g., maintain 3 points of contact with 

hands and feet) when ascending or descending any portion of the ladder 

unprotected by the system.

4.5 Work Positioning

* Rope Grab shall not be used as work positioning purpose.

* If the work positioning is required on the system, additional relevant 

equipment needs to be used such as WPL Work Positioning Lanyard.

* There are hazards associated with connecting and disconnecting from 

the system. Use secondary fall arrest protection. Ensure adequate anchor 

points, landing platforms, or other means are available at connection and 

disconnection points to allow safe transitions to and from the system.

* Identify hazards in the work area that can cause injury to the user or damage 

to the system, such as: high heat, electrical hazards, chemical hazards, falling 

objects, or moving machinery.

5 General Information on the EN 365 Standard

5.1 Rescue Plan

There must be a rescue plan that is to be applied in case of emergency which 

can occur during working at height. Adequately trained personnel and rescue 

equipment must be opresent for rescue.

5.2 Anchorage Point

Anchorage point or the system should always be secured at a point above the 

user; it should have a minimum 12 kN strength and should be in accordance 

with EN 795 standard.

5.3 General Warnings

* Compatibility of different fall protection equipment must be considered as 

it can result in a dangerous situation.

* A vertical lifeline and and fall arrester is intended for use as a component in 

a personal fall arrest system.

* The user must be medically fit to use the equipment.

* Sufficient free space is required beneath the user at the workplace and user 

must check before each occasion of use, so that, in the case of a fall, there will 

be no collision with the ground or the other obstacle in the fall path.

6. Check and Validation

6.1 Before Each Use

All components of the Vertical Lifeline should be inspected by an authorized 

person or rescuer prior to each use. Additionally, annual inspections should 

be carried out by a manufacturer authorized “competent person” other than 

the user. Findings should be recorded in the “Inspection and Maintenance 

Log”. Inspection must be performed based on following criterias;

* All markings must be legible and attached to the product.

* All equipment must be free of corrosion, chemical attack, alteration, 

excessive heating or wear.

* All hardware should be free of cracks, sharp edges, deformation, 

corrosion, or any evidence of defect or damage to.

* Cable must be inspected for kinks, broken strands, corrosion, abrasion, 

or other signs of wear and damage.

* Energy absorber in line should be functional.

6.2 During Each Use

During performing the work at height if the equipment is connected with 

another system, make sure that all pieces of equipment in the system are 

correctly positioned and compatible with each other.

7. General Information

7.1 Lifespan

* There is no theoretical lifespan of metal components. Products must be 

documented by at least one time per year to determine if the product is safe 

to use. Kaya Safety is not responsible for the use of the product that has no 

annual periodic control.

* Vertical Lifeline System is made of galvanized steel and stainless steel. 

Check material specifications for further detail.

* Galvanized steel is highly resistant to atmospheric corrosion. Please refer 

to the manufacturer or authorized dealer for more information.

Regarding the corrosion occurring on the material depending on the area 

of the use. In all circumstances decision to continue to use the product can 

only be made if annual periodic control has been performed and resulted 

positive by manufacturer or a competent person authorized 

by the manufacturer. If the product has one of the deviations below it should 

be withdrawn from service immediately and should be destroyed to prevent 

further usage.

* Stainless steel is highly resistant to atmospheric corrosion. Depending on 

the area of the use superficial rust spots can be seen on the product (The 

period may shorten in industrial sites; iron powders and welding pieces.) 

Please refer to the manufacturer or authorized dealer for more information.

* It has suffered a heavy shock load or a load dropped onto it.

* If any signs of corrosion on the product is observed.

* if product was recorded not suitable for use during a control and if you have 

any doubt about that.

* Changes in standards, legislation and changes related to technical use of it, 

and similar cases.

7.2 Storage

Product comes with its own special case and user manual where the model 

number and applicable standard is written. Product should be stored in its 

case in a cool, dry place out of direct sunlight and at room temperature. Do 

not store in areas where damage from environmental factors such as heat, 

light, excessive moisture, oil, chemicals and their vapors, or other degrading 

elements may be present.

7.3 Maintenance

Taking good care of the product after each use extends the life of it. Use metal 

cleaners to clean the product. For detailed information please 

contact us on [email protected]

7.4 Changes and Repair

Changing a part, repair and addition to any component of the system is strictly 

forbidden without written authorization of KAYA. Any repairs on products 

can  only  be  done  by  manufacturer  or  qualified  persons  authorized  by  the 

manufacturer. All repair and maintenance work must only be carried out in 

accordance with manufacturer’s instructions. KAYA won’t be responsible for 

repairs performed by for unauthorized persons.Manufacturer’s instructions 

for repair and maintenance can be obtained from authorized distributor in the 

official language of the country in which the item is in service. Please contact 

authorized distributor in your country.

7.5 Transportation of Product

The product should be transported in a case to keep it away from moisture, 

chemicals and sharp edges as well as to protect it getting in contact with 

another objects.

7.6 Periodic Inspection of Product

Product must be inspected at least (12 months) once a year by manufacturer 

or a competent person authorized by manufacturer. The maintanence 

dates can be found on the warning plate. During the inspection of product 

following information should be recorded; Type of the product, model, contact  

information of producer, serial number, 

Summary of Contents for RVL-100 A

Page 1: ...s MK5 8PP UK Tel 44 0 8450 809000 Fax 44 0 8450 80900 RVL 100 A TR Dikey Ya am Hatt Merdiven Uzatmal Hat zerinde ok Emicili EN Vertical Lifeline With Ladder Extension Energy Absorber Inte grated EN 35...

Page 2: ...le Guide Malzeme ST 37 elik ve Polyamid Material ST 37 Steel and Polyamide Kaplama Dald rma Galvaniz Coating Dip Galvanized RC 30 V Alt Ankraj Plakas Bottom Anchor Plate Malzeme ST 37 elik Material ST...

Page 3: ...lik Halat tutucunuzu yere dik gelecek ekilde eviriniz ve karabinay tak n z Halat tutucunun ters tak lmas durumunda karabinan n halat tutucuya ba lanmas m mk n olmayacakt r EN Rotate F 5 Rope Grab back...

Page 4: ...ndan yap lmal d r Sistemin b t n n sorumlulu u kurulumu ger ekle tiren rmaya aittir Sistem 15 yan a lar ile test edilmi ve onaylanm t r Dikey ya am hatt kullan m nda olas bir d durumunda yap ya gelece...

Page 5: ...zel antas nda ve kullan m k lavuzu ile birlikte zerinde modeli standard yaz l olarak sat a sunulmu tur r n kendi antas i inde kuru bir yerde g ne na do rudan maruz kalamayacak ekilde ve oda s cakl nda...

Page 6: ...e Failure to follow all instructions and limitations on the use of the Vertical Lifeline System may result in serious personal injury or death The guide should not be considered as any form of trainin...

Page 7: ...legible and attached to the product All equipment must be free of corrosion chemical attack alteration excessive heating or wear All hardware should be free of cracks sharp edges deformation corrosio...

Page 8: ...his product is certi ed in accordance with PPE Regulation 2016 425 EU by BSI Assurance UK Ltd n 0086 noti ed Body after tests according to EN 353 1 2014 A1 2017 norms KAYA has Module D Quality System...

Reviews: