6. Troubleshooting
Problem
Possible Reasons
Solutions
The trolley does not cool
Power failure
Check the power presence in the
electric system
Lack and/or loss of gas from the system
Contact the retailer
The thermostat has been tampered with
or it is broken
Check the thermostat regulation or
contact the retailer
The power cable is worned out
Replace the cable with a suitable
one
The compressor is not working
Contact the retailer
The air does not flow from
the well’s holes
*
The fan is burned
Contact the retailer
The holes are stuffed up
Take out the inner well and clean
the holes from the behind
The evaporator are stuffed with ice
because of a breakdown of the heating
element for the automatic defrost
Contact the retailer
The trolley loses efficiency
after some hours of
continuous service
*
Failure in the automatic defrost system
Contact the retailer
The LED lamp does not light
up
The LED is burned
Contact the retailer
The transformer is burned
Replace with a transformer with
same characteristic or contact the
retailer
The dome electrical
raising/lowering system is
not working
The actuators are burned
Contact the retailer
The push-buttons panel is broken
Contact the retailer
Presence of an obstacle on the stroke
of the actuators
Remove the obstacle and always
keep the actuator slot free and
clean.