6
●
To change the hour, use the up/down arrows
UP
DOWN
and use this button
ECONO
on the control panel to con
fi
rm
the setting.
●
After con
fi
rming the settings, the display will show the
time when the economy mode is to start.
●
Set the hour and minutes using the arrows
UP
DOWN
and con
fi
rm the setting with this button
ECONO
.
●
Con
fi
rming the minutes with this button
ECONO
the
economy mode is set. The display returns to its normal
status.
The setting of the economy mode is remembered even
after the power cut-off.
2.6. Filtration
FILTER
In this system,
fi
ltration process is based on water ozoni-
zation. Water is sucked by the skimmer
fi
lter and then
mixed with ozone by the injector. After that, water returns
to the SPA bath through the ozone jet. Filtration process
consists on two steps. The
fi
rst step lasts 1 minute, all
three water pumps work at the highest speed, while the
heater is on. Second step of
fi
ltration procedure starts
with low speed of double speed pump activation and
ozonizing device activation. The duration of
fi
ltration de-
pends on the time setting. Filtration mode is indicated by
this special icon
on the display. Filtration process
can be suspended (the
fi
ltration icon is blinking on the
display) by switching on any of massage pumps. Filtra-
tion will return to its normal mode after 40 minutes after
user last operations. Switching the lighting on does not
suspend the
fi
ltration process.
Setting
fi
ltration parameters:
●
Press the
fi
ltration button
FILTER
●
The display will show Fdxx, where xx stands for the
fi
ltration duration from 0 to 12 hours.
●
If xx is set on 0, the
fi
ltration does not work
●
Filtration duration can be changed with these arrows
UP
DOWN
and the selected value is con
fi
rmed by pres
sing the
fi
ltration button
FILTER
●
The blinking
fi
ltration start time will appear on the di-
splay
●
Changes are made with these arrows
UP
DOWN
and
con
fi
rmed by using the
fi
ltration button
FILTER
●
De con
fi
rmar los minutos con la tecla de
fi
ltración, el
controlador recordará los ajustes y pasará al funciona-
miento normal. Si durante el proceso de ajuste no rete-
nemos ninguna de las teclas por más de 5 segundos, el
controlador saldrá del menú de ajuste de la
fi
ltración, sin
recordar los ajustes realizados.
2.7. Fast fi ltration (Boost)
The “boo” function enables to make faster water
fi
ltra-
tion. During this function, all the pumps work for 1 minu-
te. Additionally, pump 1 works in a fast gear for 45 minu-
tes along with the ozonator. The heater works normally
during the fast
fi
ltration process. After switching this func-
tion on, the „boo” sign appears on the display and is pre-
sent until this function is
fi
nished. Fast
fi
ltration process
is triggered by pressing and holding the pump 1 button
for 10 seconds. This function can be switched off earlier
by starting any other pumps.
2.8. Setting the water temperature
To set the water temperature, press the arrow buttons
UP
DOWN
on the control panel.
The selected temperature does not have to be con
fi
r-
med, but only set. The display, after 5 seconds from the
last pressing, will return to the previous status and start
showing the current water temperature. The controller
maintains the set temperature with an accuracy of
± 0,5°C (1°F). If the water temperature is lower than that
previously set, the controller will start the heater and low
gear pump1 (
fi
ltration circuit) and keep it on until the wa-
ter reaches its required temperature. If the economy
mode is on
ECONO
the controller keeps the water tempera
ture lower by 10 degrees than that previously set. After
the economy mode is off, the controller returns to main-
taining the previous temperature set.
2.9. Increasing the maximum temperature
This function allows the user to increase the water tem-
perature by two degrees centigrade above 40°C (104°F).
To set the temperature above 40°C, set the maximum
temperature and next press and hold the up arrow button
UP
for 5 seconds until the Orx.x sign apears on the
display, where x.x signi
fi
es how much the temperature
value is to be increased above the maximum temperatu-
re. This value can be increased half a degree, and the
maximum value is two grades, so the maximum water
temperature is 42° C. To return to a normal mode of set-
ting the water temperature, press the down arrow button
DOWN
a few times until the normal temperature, ranging
from 15 to 40°C, appears on the display.
2.10. “Stand-By” function
This function blocks access to all devices connected to
Summary of Contents for SPA BROADWAY ROUND
Page 1: ...1 User s Handbook SPA BROADWAY ROUND...
Page 11: ...11...