Roca LAIA GTI Operating, Cleaning And Maintenance Instructions Download Page 3

3

The LAIA Heating Unit selected will give you the
services of Heating and instant generation of Hot
Water for household use.
These instructions give you the main
characteristics of the Heating Unit as well as the
steps required for its correct operation and
maintenance.
Our Clients’ Technical Service is at your disposition
for helping to solve any problems that may arise.

Main characteristics

Model

Operating power

kcal/h kW

LAIA GTI-R-T 25.000 29,07

Maximum operating temperature: 100

°

C

Maximum pressure (heating circuit): 3 bar
Maximum pressure (hot water circuit): 7 bar
Continuous production: 13.9 I/min at 

t=30

°

C

Operation

Checks and steps to follow during service to the
Heating Unit, and at the beginning and end of every
heating season.

Operations prior to first use

- Check that the Out and Back cocks, if any, are

open.

- Open the door of the boiler.
- Check that the unit is full of water and that the

fixed hand of the thermohydrometer has been
placed in the position corresponding to the height
of the unit.

1 bar = 10m

- Purge the air from the unit and the emitters, using

the purge traps.

- Fill up with water, if necessary, until the mobile

hand of the thermohydrometer is slightly higher
than the fixed one.

First use

* LAIA Heating Units incorporate a burner which

ignites for the first time some 6 minutes after
the general switch (1) is flicked. Subsequently,
ignition is almost instant. 

Figure 1

.

* With regard to the operation of the programme

clock (2) of LAIA GTI-R Heating Units, consult
the Instructions provided.

- Adjust the boiler thermostat (3) to between 50

°

C

and 90

°

C. Move the dial of the ambient

thermostat, if any, to the position corresponding
to the ambient temperature required.

- Adjust the boiler thermostat for hot tap water (4)

to between 40

°

C (summer) and 60

°

C (winter).

- Flick the general switch (1). The pilot (5) will light

up.

- Use the switch (6) to select ”heating/hot water”

or ”hot water”.

Heating/Hot Water

LAIA GTI and GTI-R with switch at (6) 

 /

 .

LAIA GTI-T with Teletherm 

  /

 functions

activated. (See ”telephone module”.)

A - WITHOUT EXTRACTION OF HOT WATER

- The burner operates under the control of

the boiler potentiometer (3). See

 figure 1

.

- The circulator operates continuously,

unless the ambient thermostat overrides it.

B - WITH EXTRACTION OF HOT WATER

- The boiler goes to the maintenance

temperature (about 80

°

C).

- The circulator works under the control of

the electronic circuit, in function of the flow
and the temperature selected for this
service.

Hot Water

LAIA GTI and GTI-R with switch (6) at 

. LAIA

GTI-T with Teletherm 

 function activated. (See

”telephone module”.)

A - WITHOUT EXTRACTION OF HOT WATER

- The boiler remains at the maintenance

temperature (about 80

°

C).

- The circulator does not work.

B - WITH EXTRACTION OF HOT WATER

- The boiler continues at the maintenance

temperature.

- The circulator operates under the control

of the electronic circuit, in function of the
flow and the temperature selected for this
service.

In any event, the safety thermostat (7) will
disconnect the burner whenever the
temperature of the water in the boiler
becomes too high.
To reset it, press the button under the
protective cover.
Any blockage of the burner will cause the pilot
(8) to light up.
- Check that the circulator is operating

correctly and unblock it, it necessary, by
removing the twist control cap, pressing on
the groove of the shaft and turning at the
same time with a screwdriver.

- Check the performance of the burner,

following the specifications of the
Instructions manual.

- Purge and check that all emitters reach the

temperature selected on the boiler
potentiometer (3) when in operating
conditions.

- Flick the general switch (1) to ”Off”.

LAIA GTI-T Telephone module

This module is constituted by two elements: a
portable emitter control (9) which incorporates
a service switch, keypad and loudspeaker, and
also a receiver (10) for connection to the telephone
line, mounted at the control panel (See

 Figure 1

).

Remote control

The maximum duration of the telephone call is four
minutes; once this time has elapsed,
communication is cut off. If the receiver does not
receive any tone from the emitter for thirty seconds,
communication will be cut off.
- Enter the number where the receiving device is

installed. At the eighth tone, the receiver will emit
the following message: ”Roca Heating. Enter the
code”. This message can be heard through the
earpiece of the phone.

- Bring the emitter up close to the microphone in

the speaker and key in the four digits of the
access code. The initial access code is ”0000”.

a) If the code is not correct, the receiver issues

the message, ”Code incorrect. Enter the code”.
After five inaccurate attempts, the line is cut
off. If less than four digits are entered, the line
is cut off after thirty seconds. If more than four
are entered, depending on which ones, some
special function may be started (if the first four
correspond to the correct code and the
remaining ones to the function).

b) If the code is correct, the receiver issues the

message, ”Code correct. Select function”, and
awaits reception of one of the following digits:
1, 2,   (depending on the function required).

Change of code

- Press the   and 1 keys, in this order. The

receiver says, ”Enter new code”.

- Enter the four digits of the new code (  and #

may not be included), followed by *. The receiver
repeats, ”Enter new code”.

- Enter the four digits of the code again.

a) If the two series of digits were not the same,

the receiver gives the message, ”Enter the
code” and the steps for changing the code must
be repeated from the beginning.

b) If the two series of digits were the same, the

receiver says, ”Code correct. Select function”,
and awaits reception of one of the following
digits: 1, 2,   (depending on the function
required).

Consultation or change of status of
the ”Heating” service

- By pressing key 1 of the emitter, you will be

informed of the status of the heating service.
The receiver will state, ”Heating on” or ”Heating
off”.

If you wish to change the status, press key 1 again.

Consultation or change of status of
the ”H.W.S.” service

- By pressing key 2 of the emitter, you will be

informed of the status of the hot water service.
The receiver will state, ”Hot water on” or ”Hot
water off”.

If you wish to change the status, press key 2 again.

Operation over the receiver

When the receiver is connected to the supply
voltage, the 

 LED remains off and the receiver

does not accept any tones emitted via the
microphone and does not issue any messages via
the loudspeaker (see ”off position”). The receiver
incorporates three switches: 

 (heating), 

(HWS) and 

 (loudspeaker).

Once the receiver is receiving supply voltage, the
green voltage LED 

 will light up.

”Heating” selection

- Press the 

 key. The 

 LED:

- lights up = the heating service is operating

normally.

- does not light up = the heating service is

disconnected.

”Hot water” selection

- Press the,

 key. The,

 LED:

- lights up = the HWS service is operating

normally.

- does not light up = the HWS is disconnected.

”Loudspeaker” selection

At OFF.
- Press the 

 key. (*)

(*) This is not necessary when connecting the receiver to

the mains for the first time.

The 

 LED is off and the receiver:

- Does not admit tones from the emitter via its

microphone.

- Does not issue messages via its loudspeaker.
- Admits messages on the phone line at the eighth

call.

- Issues messages on the phone line.

At ON
- Press the 

 key. The 

 LED lights up and the

receiver:
- Admits tones from the emitter via its

microphone.

- Issues messages via its loudspeaker.
- Admits messages on the phone line at the

eighth call.

- The ”loudspeaker” LED flashes slowly while a

call is being answered by the receiver

Disconnected

- Press the 

 key for 3 seconds. The 

 LED

will flash rapidly and the receiver:
- Is disconnected from the phone line.
- Does not answer any calls.

Press the 

 key to return to the ON position.

GB