Issue 1 190814
1.Ensure mains supply is switched off before commencing
work.
2.Select suitable location for luminaire,
3.Remove bracket from luminaire, mark wall with
appropriate fixing positions. Before drilling, ensure that the
hole does not impinge on pipe work, cables or other
building services.
4.Mount bracket on wall and re-attach luminaire
5.The luminaire is supplied with 1m of rubber cable. Using
suitable IP rated enclosure terminate Brown (Live), Blue
(Neutral) and Green/ Yellow (Earth) to switch supply.
6. This product has no user serviceable parts. If any part is
damaged, disconnect from mains and discontinue use.
Note: No “fixings screws provided”, please use appropriate
fixings screws.
Page 1
MAX 20W LED FLOOD LIGHT
RLEDF20W-24
INSTRUCTION MANUAL
Model No.
:
Power (W):
Supply voltage:
CCT:
Lumen:
CRI:
PF:
Average Lamp Life:
Safety Class:
Ambient temp:
Ingress Protection:
Depth (mm)
:
Width(mm):
Height (mm):
Weight (kg):
Warranty:
RLEDF20W-24
20W
220-240V~ 50/60Hz
3000K
1500lm
70
≥0.9
35,000 Hours
Class I , Must be Earthed.
-15ºC <Ta < 40ºC
IP65
105mm
180mm
160mm
1.18Kg
3 years
EN60598-2-5:1998, EN62493:2010,
EN60598-1:2008+A11:2009,
EN61347-2-13:2006,
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or
use of this prodcut, consult a competent electrician
Note:
Product technical information and specification may change over time without prior notification
For the latest technical information please visit our web site WWW. ledgrouprobus. com or robusdirect. com
Information for the Product user:
1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with
crossed out wheelie bin symbol).
2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre for waste electrical
equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
3. This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is
separated from normal household waste and recycled in the WEEE chain
4. The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but should be
disposed of according to local WEEE regulations
The Installation must be carried out by an electrician
LED Group
Western Retail Park
Tel: +353 1 7099000
Nangor Road
Fax: +353 1 7099060
Dublin 12
Email: [email protected]
Ireland
Website: www.led.ie
ISO 9001:2008
Q UAL IT Y ASSU RED CO MPANY
Specifications
Installation:
Projection distance: 12m - 18m
Max projection area: 18m x 10m
Mounting height: 2.5m - 6m