background image

 

10

 

6.  Turn the 

 knob to set the desired value.

7.  Press the 

 knob to confirm the value entered. The day 

stops flashing and the 

 icon disappears.

8.2 

 

 DAY ROOM TEMPERATURE SETTING

1.  Press the 

 key until the 

 icon starts flashing (Figure 

8.4 

p. 10).

2.  Turn the 

 knob to set the desired value.

Figure 8.4  

 Day room temperature setting

 

8.3 

 

 NIGHT ROOM TEMPERATURE SETTING

1.  Press the 

 key until the 

 icon starts flashing (Figure 

8.5 

p. 10).

2.  Turn the 

 knob to set the desired value.

Figure 8.5  

 Night room temperature setting

 

8.4 

 

 HEATING  TEMPERATURE  SETTING

1.  Press the 

 key until the 

 icon starts flashing (Figure 

8.6 

p. 10).

2.  Turn the 

 knob to set the desired value.

Figure 8.6  

 Heating temperature setting

This temperature value for models of the Caldaria family 

must be set to 80 °C. The change of this value will be 

operative on the boiler until the remote control is con-

nected to it.

8.5 

 

 DHW TEMPERATURE SETTING (NOT 

APPLICABLE)

8.6 

 

 OUTDOOR PROBE KD VALUE SETTING 

(NOT APPLICABLE)

9  

 SETTING  MANUAL/AUTOMATIC  OPERATION

The remote control provides the possibility to manage the room 

temperature in two ways: manual or automatic.

 

In manual mode, the user selects the desired room temper-

ature, which will be maintained until a new change is made.

 

In automatic mode, the room temperature setpoint is de-

termined by the time and day corresponding to the weekly 

program set.

9.1 

 

 MANUAL  OPERATION

1.  Press the 

 key until the 

 icon appears. The display 

shows the set temperature value flashing (Figure 9.1 

p. 11).

2.  Turn the 

 knob to set the desired temperature.

3.  After the 30-second time delay, the central display returns to 

the current temperature.

Summary of Contents for OCDS006

Page 1: ...for Caldaria Remote control Installation and operation manual...

Page 2: ...this publication are not affected With the aim of continuously improving the quality of its products Robur S p A reserves the right to modify the data and contents of this Installation and operation...

Page 3: ...erature setting p 10 8 5 DHW temperature setting not applicable p 10 8 6 Outdoor probe Kd value setting not applicable p 10 9 Setting manual automatic operation p 10 9 1 Manual operation p 10 9 2 Auto...

Page 4: ...ing to be made The remote control can be programmed with extreme ease a large LCD display makes this operation easier allowing you to check the settings you have made and to change them at any time Th...

Page 5: ...lt requiring technical service Night level Day level 3 INSTALLATION For installation of the remote control on the Caldaria Plus refer to the Installation use and maintenance manual supplied with the C...

Page 6: ...control 5 Fix the remote control to the fixing box by first inserting the upper part and pivoting on it until it is completely closed Figure 3 4 p 6 Figure 3 4 Closing the remote control 6 Power the...

Page 7: ...save the value 8 To exit the configuration mode press Figure 4 2 Changing the selected value flashing The editable parameters are as follows P00 Room temperature probe correction Value to add subtrac...

Page 8: ...press the knob within 10 seconds 4 The display shows the flashing number of the parame ter instead of the time and the value associated with the parameter instead of the temperature 5 Turn the knob to...

Page 9: ...elected state Selected status Identification icon clock day temperature night temperature The value of the item is displayed in the lower left corner instead of the time together with the flashing of...

Page 10: ...for models of the Caldaria family must be set to 80 C The change of this value will be operative on the boiler until the remote control is con nected to it 8 5 DHW TEMPERATURE SETTING NOT APPLICABLE 8...

Page 11: ...entification icon of the heating program operation Function Identification icon heating program display PROG not flashing change heating program PROG flashing Once the changes have been made press the...

Page 12: ...change made Figure 11 1 p 12 3 To deactivate the function before it expires press the key Figure 11 1 Temporary change of the room setpoint 12 FAULT SIGNALS Any faults are displayed by the remote con...

Page 13: ...o the set tem perature for the active temperature level day night manu al Figure 13 1 p 13 Figure 13 1 Set room temperature display Delivery probe temperature display corresponds to the temperature re...

Page 14: ...08 00 16 30 22 00 00 00 06 00 08 00 16 30 22 00 Saturday Sunday 00 00 07 00 23 00 00 00 07 00 23 00 How to reset default values 1 Set the remote control to the OFF mode 2 Press and hold down the and k...

Page 15: ...for antifreeze function 0 0 C OFF 0 1 10 0 C Stop temperature for the room antifreeze function set value 0 6 C Heating time programming resolution 30 minutes Maximum number of daily on off 48 Number...

Page 16: ...ingonia BG Italy 39 035 888111 F 39 035 884165 www robur it robur robur it Robur is dedicated to dynamic progression in research development and promotion of safe environmentally friendly energy effic...