Heating engineer
16
3
Figure 3.6
Support bracket positioning and holes drilling
A Bracket fixing holes
B
Support bracket
C
Adhesive gasket
D Air pipe
B
D
C
A
A
7. Position the support bracket and the air intake pipe Ø
49, making sure that the pipe edge perfectly enters the
matching hole in the bracket (see Figure 3.6
8. Fix the support bracket with the screws and position
the round adhesive gasket around the hole in the
bracket (see Figure 3.6
9. Position the self-adhesive foam gasket strip on the
support frame (at the rear of the gas-fired convector)
as shown in Figure 3.7
p. 16. Try to avoid reposition-
ing which could be difficult.
10. Fit the end of the flue gas exhaust pipe (Ø 35 mm)
onto the gas-fired convector outlet socket (Figure
3.8
11. Mount the gas-fired convector to the wall by resting
slot C on the lower edge of the frame on the support
bracket, as shown in Figure 3.9
Figure 3.7
Positioning the gasket
1
Self-adhesive gasket
1
Figure 3.8
Positioning the flue gas exhaust pipe
1
Flue gas pipe Ø 35 mm
1
Figure 3.9
Attachment to the support bracket
A Bracket end for hooking to the gas-fired convector
B
Lateral eyelets for fixing to the bracket
C
Lower eyelet for fixing to the bracket
D Holes for securing the gas-fired convector to the wall
A
A
B
B
D
C
D
12. Fit the slots B to the ends A of the support bracket
and push the gas-fired convector towards the wall so