FOR YOUR SAFETY READ BEFORE OPERATING

   

 
 
 
 
 
 
A.  This appliance does not have a pilot. It is 

equipped with an ignition device which 
automatically lights the burner. Do not try to light 
the burner by hand. 

B.  BEFORE OPERATING smell all around the 

appliance area for gas. Be sure to smell next to 
the floor because some gas is heavier than air 
and will settle on the floor. 

WHAT TO DO IF YOU SMELL GAS:

 

- Do not try to light any appliance 
- Do not touch any electric switch 
- Do not use any phone in your building 
- Immediately call your gas supplier from a   
neighbour’s phone. Follow the gas 
supplier’s instructions. 

 
 
 

 

 

- If you cannot reach your gas supplier, call the 
fire department. 

C.  Use only your hand to push in or turn the gas 

control knob. Never use tools. If the knob will not 
push in or turn by hand, don’t try to repair it, call a 
qualified service technician. Force or attempted 
repair may result in a fire or explosion. 

D.  Do not use this appliance if any part has been under 

water. Immediately call a qualified service 
technician to inspect the appliance and to replace 
any part of the control system and any gas control 
which has been under water. 

 

 

 

OPERATING INSTRUCTIONS

 

 

 
1.  STOP! Read the safety information above on this 

label. 

2.  Set the control switch to “OFF” position. 

3.  Turn off all electric power to appliance. 

4.  This appliance is equipped with an ignition device 

with automatically lights the burner. Do not try to 
light the burner by hand.

 

 

                

 

 
5.  Remove control access panel. 

6.  Push in gas control knob slightly and turn 

clockwise               to “OFF”. 
NOTE: Knob cannot be turned to “OFF” unless 
knob is pushed in slightly. Do not force. 

7.  Wait (5) minutes to clear out any gas. If you then 

smell gas, STOP! Follow “B” in the safety 
information above on this label. If you don’t smell 
gas, go to the next step. 

8.  Turn gas control knob counterclockwise             to 

“ON”. 

9.  Replace control access panel. 

10.  Turn on all electric power to the appliance. 

11.  Set thermostat to desired setting. 

12.  If the application will not operate, follow the 

instructions “To Turn Off Gas Of Appliance”  

 
 

 

 

TO TURN OFF GAS TO APPLIANCE

 

 

 
13.  Set the control switch to “OFF” position. 

14.  Turn off all electric power to the appliance if 

service is to be performed. 

15.  Remove control access panel. 

 
16.  Push in gas control knob slightly and turn 

clockwise              to “OFF”. Do not force. 

17.  Replace control access panel. 
 

WARNING: 

If you do not follow these instructions exactly, a fire 

or explosion may result causing property damage, personal injury 
or loss of life. 

 INLET

   

 

 

          

OUTLET

 

GAS CONTROL KNOB 
SHOWN IN “ON” POSITION 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances 

Summary of Contents for ACF60-00 Series

Page 1: ...structions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If you don t follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life IF UNIT OVERHEATS OR UNIT S GAS VALVE FAILS TO SHUT OFF DO NOT SHUT OFF ELECTRICA...

Page 2: ...2 Set the control switch to OFF position 3 Turn off all electric power to appliance 4 This appliance is equipped with an ignition device with automatically lights the burner Do not try to light the burner by hand 5 Remove control access panel 6 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned to OFF unless knob is pushed in slightly Do not force 7 Wait 5 minut...

Page 3: ...n authorized Robur Technical Assistance Center TAC will check the unit for correct operation every two years If the unit is subjected to particularly heavy use for example in processing plants or in other conditions of continuous operation these maintenance operations must be performed more often Inspection and cleaning of the flue gas passage You will need the unit shut off 1 Turn off gas and ele...

Page 4: ...ency products through the commitment and caring of its employees and partners Robur Mission Robur Corporation advanced heating and cooling technologies 827 E Franklin Street Evansville Indiana 47711 USA P 812 424 1800 F 812 422 511 7 www robur com us rhalbig servel sbcglobal net Codice D LBR370 rev B 06 MCM PSS 040 30 11 2006 ...

Reviews: