Normal operation
30
6
The value of the antifreeze temperature must be
between 2,0 and 10,0 ºC (in steps of 0,1 ºC).
5.
To confirm the set value, press the
key. This will
move you to the next setting.
6.
After setting the desired temperatures, press the
key to exit the programming mode.
Figure 6.2
Comfort, reduced and antifreeze temperatures
6.3.4
Free programming of daily setpoints on
the chronothermostat
1.
Enter programming mode by shortly pressing the
key.
2.
Press the
key repeatedly.
3.
On the lower left of the display, the message SP n will
appear, where n indicates the number of the daily set-
point (Figure 6.3
p. 30).
Figure 6.3
Daily setpoint
The daily setpoint refers to the time at which the
operating setting, i.e. the desired temperature
level, changes. The set temperature value remains
valid until the next setpoint.
4.
Set the desired day of the week using the
key.
5.
Use the
and
keys to select the setpoint to be
set.
6.
Set the time using the
and
keys (minimum
steps of 10 minutes).
7.
Set the desired temperature level using the
key:
the sun icon for the comfort setpoint, the moon icon
for the reduced setpoint and neither icon for the an-
tifreeze setpoint will appear on the top right of the
display.
8.
The set time and temperature level will also be dis-
played on the display clock (see Figure 6.4
9.
To move on to the programming of the next setpoint,
press the
or
key and set the time and tempera-
ture level as previously done: for each daily profile it is
possible to set up to 8 setpoints.
10.
In the example of Figure 6.4
p. 30 for Monday, 7 set-
points have been set as specified below:
Setpoint 1 at 00:00 antifreeze temperature
Setpoint 2 at 07:00 econm temperature
Setpoint 3 at 08:00 comfr temperature
Setpoint 4 at 11:00 econm temperature
Setpoint 5 at 14:00 comfr temperature
Setpoint 6 at 18:00 econm temperature
Setpoint 7 at 19:00 antifreeze temperature
Figure 6.4
Daily setpoint
When freely programming the daily setpoints, it
is important to always program all 24 hours as in
the example in Figure 6.4
p. 30. If you leave un-
scheduled time slots, the chronothermostat auto-
matically applies the data set the previous day in
those same time slots (even if this is not shown on
the display).
In order to simplify the free programming of
the daily setpoints, it is possible to associate a
preset daily profile to a specific day (Paragraph
6.3.5
p. 31) and then select the same day in free
programming mode of the daily setpoints (using
the
key) and proceed to the modification of
the daily profile by scrolling with the
and
keys the setpoints and changing the time using the
and
keys, and the temperature level via
the
key.
11.
Once the daily profile and its temperature setpoints
have been programmed, press the
key to confirm.
Confirming with the
key causes the loss of the
daily profile previously set for the same day. Failure
to confirm will result in the loss of all settings en-
tered for that daily profile.