53
Appendix B: Pumper Fuse Block Detail
Pumper Fuse Block Detail
0 brown wire 1 blue wire 2 blue wire 3 white wire 4 yellow wire 5 purple wire
SWITCHED
OUTPUTS
&
Patches
Board +12V
20 AMP
5 VOLT
REG.
3 AMP
RC
Receiver
5 VOLT
REG.
3 AMP
Processor
RIGHT
DRIVE
20 AMP
(super)
15 AMP
(standard)
LEFT
DRIVE
20 AMP
(super)
15 AMP
(standard)
AUDIO
5 AMP
Red wire
Red wire
Red wires - +12 Volt
Power wires from
Main On/Off Switch
All Fuses are AGC type fuses.
Audio - (Fuse 0) Robot voice transmitter (151), Robot voice receiver (101), audio booster,
active filter, cassette player, siren.
Switching - (Fuse 4) Cassette player, siren, headlights, beacon, and water squirter. This
applies to the switching on and off of these functions. Power to Patches control board which
includes head turning, mouth, steering servo, and eyes servos(eyes servo board).