Serial (RS-232) Controls and Operation
146
AX2550 Motor Controller User’s Manual
Version 1.9b. June 1, 2007
This parameters selects the various open loop and closed loop operating modes as well as
the feedback method.
Amps Limit
Address:
^02
Access:
Read/Write
Effective:
After Reset or ^FF
This parameter configures the controller’s Amps limit. Note that this limits the amps flow-
ing out of the power supply. Current flowing through the motors may be higher.
Bit
Definition
See pages
2:0
Motor Control Mode
0 = A & B separate speed open loop
(default)
1 = A & B mixed speed open loop
2 = A speed open loop, B position
3 = A & B position
4 = A & B separate speed closed loop
5 = A & B mixed speed closed loop
6 = A speed close loop, B position
page 42
page 97
page 85
6:3
Reserved
6
Ch1 Feedback type
0 = Analog
1 = Encoder
page 97
page 85
7
Ch2 Feedback type
0 = Analog
1 = Encoder
Bit
Definition
See pages
3:0
Coarse Amps
0 = 30A
1 = 45A
2 = 60A
3 = 75A
4 = 90A
5 = 105A (default)
6 = 120A
page 44
7:4
Fine Amps
Substract this number from the Coarse
Amps value
Summary of Contents for AX2850
Page 2: ...2 AX2550 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 4: ...4 AX2550 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 12: ...12 AX2550 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 14: ...Important Safety Warnings 14 AX2550 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 96: ...Closed Loop Position Mode 96 AX2550 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 164: ...164 AX2550 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 170: ...170 AX2550 Motor Controller User s Manual Version 1 9b June 1 2007...