![Robot Pumps RW-R-SERIES Operation & Maintenance Manual Download Page 17](http://html1.mh-extra.com/html/robot-pumps/rw-r-series/rw-r-series_operation-and-maintenance-manual_1471271017.webp)
Operation &
Maintenance Manual
Pump
RW-R
18/28
Edition 1
HSC
02-W51
782-007-GB
7.7
Motor housing
7.7.1 RW 20
Unscrew the inspection plug of the motorhousing (see
Fig. 7.6 pos 1).
Put the pump in horizontal position with the inspection
opening downwards.
If water is present this will come out this way.
A small amount of water, due to condensation, is
permissable.
More water is an indication of leakage of
the construction. Oil is an indication of
seal failure between motorhousing and oil
chamber. If so, contact your dealer.
7.7.2 RW 40
Unscrew the inspection plug of the motorhousing.
This plug is found at the opposite side of the cable
entries (see Fig.7.7 pos 1).
Put the pump in horizontal position with the inspection
opening downwards. If water is present this will come
out this way.
A small amount of water, due to condensation, is
permissable.
More water is an indication of leakage of
the construction. Oil is an indication of
seal failure between motorhousing and oil
chamber. If so, contact your dealer.
Fig. 7.6
Fig. 7.7
www.robotpompen-onderdelen.nl
T +31(0)294-457712