ALARM MESSAGES
In the event of a breakdown during operations the ma-
chine stops automatically and alarm messages appear
on the display.
The table lists the displayed messages, the type of
problem, the cause and possible solutions.
Information
For these operations a precise technical skill or
ability is required and must therefore be
exclusively performed by qualified personnel with
certified experience acquired in the specific field.
Alarm
Problem
Cause
Solution
E01
Emergency alarm mushroom
button.
Emergency alarm mushroom button
pressed.
Reset the button and press the Reset
button.
E10
Emergency bumper alarm.
The bumper hit an obstacle in the
working area.
Remove the obstacle and press the
"Reset" push-button.
E11
Cover open alarm.
Protection cover open.
Close the cover and press the Reset
button.
The microswitch does not work.
Replace the microswitch.
E30
Drive motor alarm.
Drive motor failure.
Check motor operation and consult
the electric plant diagram.
E31
Carriage motor alarm.
Carriage lift motor failure.
Check motor operation and consult
the electric plant diagram.
E32
PFS motor alarm.
PFS-type spool carriage film stretch
motor failure.
Check motor operation and consult
the electric plant diagram.
E33
Inductive malfunction alarm.
Inductive sensor malfunction.
Check the conditions of the inductive
sensor.
E34
Spool carriage lifting encoder
alarm.
Spool carriage lifting encoder
malfunction.
Check encoder operations consulting
the wiring diagram.
E60
Film end/broken alarm.
The film is broken or the spool is
empty.
Insert the film or replace the reel.
E70
Function disabled alarm.
A function was selected from the
control panel that is not enabled for
the type of spool carriage installed
on the machine or the keyboard
block is on.
Select another function from the
control panel or release the keyboard
E80
Charge battery alarm.
Battery charge failure.
Check the battery charger and refer to
the wiring diagram.
E90
Uncharged battery alarm.
The battery has run down to the
safety level; the machine will stop.
Convey the machine to the next re-
charge point by using the forward/
backward manual buttons positioned
on the drawbar (see 6.12.).