1.0

 

PRODUCT SUMMARY 

EDFA-4429 series high power single mode EDFA is characterized by low noise and 
high linearity. It offers a flexible, low-cost solution for CATV large area coverage of 
metropolitan  areas  and  medium-sized  cities.  EDFA-4429  series  amplifiers  are 
equipped with complete APC, AGC and ATC controls and have an excellent design 
for heat-dissipation, guaranteeing long MTBF values for the laser pump. RS232 and 
RJ45 interfaces on the front panel offer serial communication and SNMP network 
access  for  local  or  remote  management.  The  wide  LCD  screen  displays  all  the 
operating parameters and any alarms. Laser will be automatically switched off if 
optical input power is missing, protecting the laser and automatically resuming 
operation when new input is detected. All optical outputs are located on the front 
panel (optional order for back panel is available). 

EDFA-4429:  1RU  chassis,  total  output  power  >1000mW,  offers  maximum  16 
optical outputs. 

 

 

2.0

 

INSTALLATION 

2.1

 

Unpacking 

Please inspect the shipping boxes for any obvious damages.   
Unpack the unit from all packaging boxes. 
Inspect the appearance of the unit for any shipping damages.   
Document and inform the shipping company and your local representative, if 
any damage was found. 
Save the shipping boxes and their inserts for future reshipment in case the 
products need any upgrade or repair. 

 
NOTE:  When  reshipping  products  (returning  them  back  to  the  vendor, 
distributor or manufacturer), warranty will be void if products are damaged 
due  to  use  of  non-original  protection  packaging.  The  EDFA  units  contain 
sensible mechanical parts that can be damaged by improper handling. 

2.2

 

EDFA Mounting and Power Connection 

1.

 

Place the unit into a 19-inch wide rack or cabinet. Make sure to leave a 

1.75-inch (about 4.5cm) space above and below the unit. 

2.

 

The

 

EDFA-4429  series  1550nm  can  work  between  0°C~50°C

32°F~122°F

temperature range. We recommend 25°C

77°F

environment 

temperature.  Humidity  should  not  exceed  95%

under  non-condensing 

Summary of Contents for EDFA-4429 Series

Page 1: ...1 15 55 50 0n nm m C CA AT TV V E Er rb bi iu um m D Do op pe ed d F Fi ib be er r A Am mp pl li if fi ie er r E ED DF FA A 4 44 42 29 9 S Se er ri ie es s U US SE ER R M MA AN NU UA AL L Ver 2 0en ...

Page 2: ...ectivity 2 3 0 EDFA CONTROLS INDICATORS AND ALARMS 4 3 1 Operation of the panel 4 4 0 PORT AND CABLE ASSIGNMENTS 6 4 1 Management Port RJ 45 7 4 2 RS232 Console port DB9 9 4 3 Power Connection 10 5 0 FAULT MESSAGES 10 5 1 Warning status 11 5 2 Alarm status 11 5 3 Fault troubleshooting 11 6 0 WARRANTY AND REPAIRING UNITS 12 ...

Page 3: ...chassis total output power 1000mW offers maximum 16 optical outputs 2 0 INSTALLATION 2 1 Unpacking Please inspect the shipping boxes for any obvious damages Unpack the unit from all packaging boxes Inspect the appearance of the unit for any shipping damages Document and inform the shipping company and your local representative if any damage was found Save the shipping boxes and their inserts for f...

Page 4: ...t power supply the equipment chassis must be grounded following the appropriate procedures for the respective location 2 3 Optical connectivity 1 Clean all fiber patch cords before connecting to the EDFA unit Cleaning Guidelines Fiber Patch cord connectors Remove the dust cap of the fiber connectors and wipe the fiber connector tip with a dry lint free cloth Check if there are scratches or debris ...

Page 5: ... panel and disconnect each fiber connector from the bulkhead mounted on the plate Clean each fiber connector according to the fiber cleaning guidelines 2 Make sure the laser key switches on the front panel of the transmitter are in the OFF position 3 Connect the fiber patch cord from the output of the transmitter to the optical power meter 4 Turn the transmitter laser key switch to the ON position...

Page 6: ...ct 48V power supply B Turn on power switch in the back panel Front panel displays KEY OFF Laser Status lamp is Red C Input power then press laser start up key switch Front panel shows KEY ON Laser status lamp turns green from red 3 1 2 Start up main menu Press buttons and the following menu will be displayed in a sequence cycle Menu 1 Model Read only menu tells the type of this equipment Menu 2 S ...

Page 7: ...u tells the status of power1 Menu 12 Power2 Read only menu tells the status of power2 Menu 13 Unit Temp Read only menu tells the case temperature Menu 14 IP Adjustable list displays the IP address Menu 15 SUB Adjustable list displays the address of net mask Menu 16 GW Adjustable list displays the gateway address Menu 17 TR1 Adjustable list displays the TRAP1 address Menu 18 TR2 Adjustable list dis...

Page 8: ...me time to select 5 this position then press button to change 5 to 6 and then press button at same time to save the modified IP is 192 168 000 016 3 LCD Contrast Level Set LCD Contrast Level Select this menu press the button at the same time to enter the modified status press the button to set the brightness of the LCD last press the button at the same time to save 4 Set Reset Settings menu Choose...

Page 9: ...t such as other EDFA 4429 or network Hub Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 ohm Category 3 4 or 5 cable for 10 Mbps connections or 100 ohm Category 5e cable for 100 Mbps connections Please make sure that the cable length does not exceed 100 meters 305 feet 4 1 2 Pin assignment For network management connectivity RJ 45 connector in each side...

Page 10: ...or MDI X of the EDFA 4429 series and any device with a standard network interface such as a work station or server or to a network interconnection device such as a bridge or router 1 Ensure that the device to be connected has a 10BASE T or 100BASE TX network interface card NIC 2 Prepare a twisted pair Ethernet cable with RJ 45 plugs on each end Use Cat 3 4 or 5 cable for standard 10Mbps Ethernet c...

Page 11: ... 3u standard has more strict order for high speed Ethernet So when cascade device except for this EDFA 4429 series please follow the above connection regulation But please don t reckon in the EDFA 4429 series or connected cable related device in cascade length because EDFA 4429 series divide the connected path into unattached port 4 1 4 Connection Management Out Band Remote management can be perfo...

Page 12: ...g of data 3 TXD transmitter data 5 SG signal Table 4 3 Pin information 4 3 Power Connection 4 3 1 Connection Description The power module provides stable operating power for the system to meet the power supply requirements of all the components in the system 5 0 FAULT MESSAGES EDFA 4429 series FTTP EDFA can monitor system operation and generate brief warning notes taking corrective actions regardi...

Page 13: ...rn to their normal status and there is no need for user to interfere But what should emphasize is that the problem showed by alarm cannot be ignored because there may be some serious system faults Work status Status display LED color Explanation Present laser deflection is low Key Off Red The EDFA isn t working It s shut down Present case temp Red Warning when the temp 60 C Input Input Low Red Opt...

Page 14: ...ide two years warranty for the product 2 The software CPU has the purpose of monitoring laser status digital display alarms and network management In case of red LED blinking Alarm please return the equipment for repairing User should not open the top cover for repairing opening the cover of the EDFA unit will void the warranty maintenance and material fees will be charged for repair if the unit h...

Reviews: