MAINTENANCE
Grease filters
CLEANING METAL SELF-SUPPORTING GREASE FILTERS
Odour filters (Recirculation version)
REPLACING THE ACTIVATED CARBON FILTERS
The filters must be cleaned every 2 months of oper-
ation, or more frequently with heavy usage, and can
be washed in a dishwasher..
• Remove the filters by releasing the fixing hooks.
• Wash the filters, taking care not to bend them.
Allow them to dry before refitting.
• When refitting the filters, make sure that the
handle is visible on the outside.
These filters are not washable and cannot be
regenerated, and must be replaced every 4 months
of operation, or more frequently with heavy usage.
• Remove the grease filters.
• Remove the saturated activated charcoal filters as
shown (A).
• Fit new filters (B).
• Replace the grease filters.
A
B