background image

  When the charger is subjected to considerable temperature differences, (especially 

from cold to hot) let the condensation dry up first, before you use the Twin Charger. 
Condensation water could otherwise destroy the charger.  

 

 

  If you may assume, that the Twin Charger cannot be used safely any more, you must 

immediately stop using it and secure it against unintended operation. Such an 
assumption can be made if the Twin Charger: 

Robitronic Twin Charger - Instruction Manual 

- is apparently damaged. 
- malfunctions  

Art. No. R01002 

- is stored in an adverse environment for prolonged periods of time. 

 

 

Warranty 

 

With the purchase of this product you purchased at the same time a two-year warranty 
from date of purchase. The guarantee applies only to the already existing material on 
the purchase of the product and / or functional defects.  

Charging Batteries 

  Connect the Twin Charger’s mains cable to a 110-240V~ 50-60Hz source. Once the 

middle led flashes red briefly, the Twin Charger functions correctly is ready to use. 

  Before you plug the battery to the Twin Charger, check the correct polarity of the 

connectors. (See illustration below.)

 

 

 

  

 

Excluded from the guarantee:  

  Damage caused by incorrect use  

  Damage caused by neglect of duty of care  

Black (-)                 Pic 1 

  Damage caused by improper handling and maintenance errors  

Red

 (+) 

 Liquid damage  

For warranty claims, please contact your local dealer. 
Should it be necessary to send the product, you must enclose a copy of the invoice and 
a repair order. You can download it at www.robitronic.com. With direct sending to the 
service department must be consulted beforehand (held by telephone or e-mail). The 
postage costs borne by the consignor. Paid packages are not accepted. Everyone sent 
in warranty case is first examined by our service department on admissibility. For reject 
warranty claims will be charged back to a control and processing fee before we return 
the product. Repairs not covered under warranty, before the start of the repair must be 
paid. Robitronic assumes no liability for damages and losses directly or indirectly, by 
the sequence of use or misuse of this product and its required accessories products 
needed for their operation, arise.  

 Connect the discharged NiMH battery to the appropriate charging harness of the 

Twin Charger, this means 
Black harness for 7-8 cells with 120 mA, 
Red harness for 4-7 cells with 900 mA charging current. 

 When using the charging plug for remote control, please note the polarity of the 

remote control. Connect the charging plug to the adapter so, that “TIP” according to 
the polarity of the remote control, is facing to “+POS” or “-NEG” (see for example  
Pic 1). “TIP” is the inner pole of the charging plug. 

 

  The red LED indicates the charging process 

Intended use of the Twin Charger 

Once the LED lights up green, charging is completed and the battery is ready for use 
(only 4-7 cells 0,9A output). The Twin Charger now switches to trickle charge to keep 
the battery fully charged. Now, disconnect the battery from the Twin Charger. If the 
battery feels cold, charging has been interrupted early due to a false delta peak. 
Such false delta peaks are especially common with old or poor batteries. Should 
such an early delta peak occur, simply disconnect and reconnect the battery to the 
Twin Charger. You can estimate the charging time through the following formula:  

The Twin Charger can be directly powered off the mains current (110-240V~ 50-60Hz) 
and is suitable for charging simultaneously any NiMH battery pack from 4-7 cells and 
NiMH transmitter pack from 7-8 cells compatible with quick charging. 
The charger is protected against overloading and short circuits as far as possible. It is 
designed to work maintenance free. Care must be taken when determining the polarity 
of the battery. It’s not allowed to operate the Twin Charger in adverse environments, 
such as: 

Charging time (h) = battery capacity (Ah) x 1.2 / charging current (A)  

- High humidity  

  By use 7-8 cells 120 mA output, the maximum charging time is to calculate according 

the formula and to disconnect manually.  

- Wet conditions 
- Dust or combustible gases, vapors, solvents or benzene 

  When charging has finished, unplug both the battery and the charger. 

- High temperature (> approx. +40°C) 

 

- Heavy vibrations 

Note:

 Should the red and the green LED flash permanently, then there’s a problem with 

the Twin Charger. Disconnect the battery, unplug the charger from the mains and try 
again after about 10 seconds. When you plug the Twin Charger to the mains while the 
battery is connected, and the red LED doesn’t flash, you should immediately 
disconnect the battery and the charger to avoid damage. 

 
The charging process is indicated by a red LED. 
The cell count selection is automatically determined by the charger.  
The charging current amounts to max. 900mA (0,9A) and max. 120mA (0,12A) 
 

Possible causes for the malfunction can be: 

The Twin Chargers intelligent “delta-peak” design detects a fully charged battery and 
ends the charging process automatically, switching to a low-current trickle charge (only 
4-7 cells 0,9A output). This way, the battery won’t get overcharged but stays at its 
maximum capacity. By use 7-8 cells 120 mA output, the maximum charging time is to 
calculate according the formula (see Charging batteries) and to disconnect manually. 
An indicator LED constantly informs about the current operating status.  

- The battery is connected in reverse polarity. 
- The battery or a single battery is defective 
- Poor wiring resulting in a loose or no connection 
- Mains socket is dead or defective 
- Twin charger is defective 
 

Any other use of this product apart from the description above is not permitted and can 
not only damage the Twin Charger, but can also lead to short circuits, fire, electrical 
shock and personal harm. Hence, the product must not be changed or converted! 

To get the most out of your batteries, only charge them when they’ve been fully 
discharged before. This will prevent the memory effect from occurring. 
Additionally, unused batteries should be cycled (discharge/charge) once a month 
to prevent capacity loss. It’s normal for the batteries to get slightly warm during 
the charging process. Do not cover the Twin Charger so it does not overheat. 

 

Important safety advices: 

  Before you start using the Robitronic Twin Charger, please make sure that you’ve 

read this manual! Keep this instruction manual in a safe place for later reference. 
Robitronic is not liable for any warrantee claims or damages that occur from a 
nonobservance of this manual. 

 

Disposal of Electronic Waste 

Electronic waste is a commodity and must be disposed through special 
electronic waste sites. Please inform yourself about adequate facilities in your 
community area. Disposal of this product through domestic waste is illegal. 

  Chargers and accessories are not suitable for children! They’re not toys and children 

should be carefully advised, not to use primary cells or batteries other than the 
supported types with this charger. 

 

Technical Data 

  The Twin Charger should be regularly checked for damages, especially damages on 

the mains cable. In case of a damage, the product must not be used until it is 
repaired by a qualified person. (See our contact details at the end of this manual for 
further advice) 

Input voltage ....................110-240V~ 50-60 Hz 
Power consumption.......... approx. 20W 
Charge rate ......................900 mA / 120 mA 
Charge control ................. indicator-LED 

  The Twin Charger must be protected from dust, moisture, direct sunlight, heat and 

rain. This product can only be used in arid rooms. 

Operating temperature...... -10°C to +40°C, 
Dimensions (l x w x h) ...... approx. 80 x 50 x 67 mm (excluding cable set) 

  While charging, the Twin Charger must not be covered as the cases functions as a 

heat sink. Make sure that air can circulate freely. 

Never

 leave the charger 

unattended! 

Mains cable ......................approx. 90 cm 

 

  During the charging process, the battery must be placed on non-combustible, heat 

resistant and insolating surface. (e.g. a spare ceramic floor tile) Also make sure that 
there are no flammable goods nearby. 

Technical specifications, features and design are subject to change. 

  The mains cable must not be altered or coiled up during use. 

 
 

  The following types of cells and configurations must not be connected to the Twin 

Charger: 
-  Defective cells. 

Version 1.1

 

- Cells wired in parallel, any cells mixed with cells of different specifications, 
performance or age. 

Robitronic Electronic GmbH

 

Brunhildengasse 1/1, A-1150 Vienna 

-  Primary cells, Li-based batteries; 

Caution: Explosion hazard!

 

Austria 

- Batteries that are not specified with the charging currents, the Twin Charger 
employs. 

Tel.:+43 (0)1-982 09 20 

- Already charged, heated or not completely discharged batteries 

Fax.: +43 (0)1-98 209 21 

- Batteries with integrated charging or discharge circuits. 

www.robitronic.com 

 Before charging, always check with the safety recommendations of the battery’s 

manufacturer. Improper handling like reverse polarity or charging currents that are 
too high may result in the explosion of the battery with considerable additional 
damage. 

 

 

 The Twin Charger’s construction corresponds to protection rating II. (double 

insulation) Always make sure the insulation on both the case and the mains cable is 
intact  

  Keep the chargers away from transmitters (cell phones, remote controls…) as their 

emf can disrupt or destroy the destroy the Twin Charger’s electronics. 

Reviews: