Robitronic
Pro-2000
Operating instructions
2
Setup
The supply voltage requires either an automobile battery or a stabilized
power supply. When using a power supply, assure that it can supply the
necessary current. The output voltage of the power supply should be set to
12 V for charging 6 cells; excessive supply voltage causes greater heating
of the charging device. When charging batteries with 4 or 5 cells, the
charging current must not exceed 1 ampere!
The supply voltage is connected to the red cable (positive terminal) and the
black cable (negative terminal) at the back of the charger. If the
connections are reversed, the circuit is electronically broken within the
charger. In this case you need not change a fuse, but only correct the
connections.
Connecting the battery
The battery to be charged is connected to the red cable (positive terminal)
and the black cable (negative terminal) at the front of the charger. If the
battery connections are reversed, a warning signal sounds.
Starting charging
If the battery has been connected correctly, the multifunction digital display
indicates the momentary battery voltage. Pressing the
Start
key begins
charging. The LED signals that charging is in progress. The multifunction
digital display indicates charging current, battery voltage, temperature and
momentary charging time.