background image

SECTION

 

No

 

TITLE 

ASSEMBLY SYNOPSIS: IMPORTANT INFORMATION / CONSIDERATIONS 

 

PARTS LIST 

Most components should have a ‘D’ code punched into their metal surface. Identify and separate all like for like components prior to assembly. 
The ‘parts list’ also separates parts into the various sections 1 - 13 shown below. Parts can also be identified by their profile pictures and stated 
lengths etc.. 

BASE 

Base dimensions and recommendations. Ensure that your base is level as this will make assembly of the building, especially the glazing of the 
roof much more straight forward. Please be aware that the hinge door on your greenhouse opens inwards, make sure that there will be no 
interference between the door and the foundations. 

PREPARATION 

Tools required. IMPORTANT: Use WD40 or similar in the glazing bar channels and insert the black glazing rubber prior to frame assembly.  

REAR 

Take the glazing bars ‘D066’ with the rubber inserted and the diagonal braces ‘D103’, use 10mm bolts to join them to the gutter and 15mm 
bolts to the cills (note how the head of the bolt slides into each glazing bar during construction). Please also remember to slide in your 22mm 
bolts for attaching the decorative eave spandrels ‘DV100’ in section 6. 

PORCH GABLE 

 

Again ensuring that the gable framework is rubbered-up follow the diagrams to assemble each gable in the building. Make sure that you have 
inserted the extra bolts utilised in sections 4 and  5. On the roof and side corner bars not every rubber channel will require rubber unless it is to 
be utilised in a partition (see separate manual and section P).     

END GABLES 

PORCH SIDES 

The porch sides (the L-shaped area to the left and right of the porch gable between cills and gutters level) can either be built in situ piece by 
piece or built away from the structure as an L-shape and then attached in a similar manner to plain gable/s to rear. Please ensure that where 
relevant you slide 2 x 22mm bolts into the side bars for the attachment of the eaves spandrels.  

MAIN FRAME 

ASSEMBLY 

Take the rear (1) and the end gables (3) and join them together on your base. It is a good idea to tie some ladders to the sides to support them 
if you do not have anyone to hold them for you. Once the porch sides (4) have been attached to the main building then the porch gable (2) can 
be inserted between them in the same way you would attach a end gable to the rear. You will now have a T-shaped framework. It is important 
that you check that the internal diagonal measurements within the building are equal to ensure that the building is square, spending a little time 
on this now will speed up roof assembly and glazing. On buildings longer than 12’ the end gable (1) should attach to the extension sides (see 
separate manual) first before the rear maintaining 620mm spacings, e.g. a 16’ building = end (3), 4’ handed extension sides, 8’ rear (1), 4’ 
handed extension sides, end (3).      

6a 

REAR ROOF 

Attach the main ridge between the end gables and then the rubbered-up roof bars ‘DV255’ ensuring that they are fully butted up to the ridge 
and down onto the gutter. Attach your cresting before you glaze the building to give yourself more room to work. Utilise the 22mm bolts slid into 
the rear (section 1) and roof bars to attach your DV100 and DV101 spandrels. On longer models you may need to carefully prop up the roof 
and tie the sides together to keep the ridge and gutters straight (i.e. not sagging or bowed) until the building is fully glazed.  

6b 

PORCH ROOF 

The porch ridge can be fitted to the porch gable supporting its free end with ladders or a wooden sprag. The porch hips ‘DV381’ can now be 
attached between the welded porch gutter sections and the free end of the porch ridge.  A ‘lower’ height porch utilises a DV380 bracket to allow 
the porch ridge to connect to the main module. Identify all of the handed roof bars and look for their locations. Insert the rubber into their chan-
nels and when attaching ensure again that were relevant you slide in 22mm bolts for eave (x2) and roof spandrels (x2). Eave and Roof spran-
drels can now be attached using the previously inserted 22mm bolts. The ladders / sprag supporting the porch ridge free end can now be re-
moved.  
 
Prior to glazing the cresting and finials should be siliconed into place. Attaching them once the glass has been installed by leaning through vent 
apertures is more time consuming.  

7a 

VENT 

Once the vent is glazed add silicone to the vent sides and top. Stand the vent/s on their hinge (vent top) and then leave the silicone to set.   

7b 

VENT SLAM 

The slam bar ‘D079’ can be moved up and down between the roof glazing bars so that it can be butted down onto the pane of glass beneath, 
the autovent will be attached to it later on (10). 

LOUVRE 

They attach to the building during the glazing process (9) like a piece of glass with a black separator above and below them. If you are fitting an 
optional auto-louvre then you need to carefully drill (3mm bit) out the rivets which mount the handle to the frame. You can then either utilise 
those holes or create more to mount the unit.  

GLAZING 

Layout the bar cappings and covers around the building like a sundial checking that all is present and correct. You can also place the roof 
cappings in the gutters so they are closer to hand. The glass in the sides has to bevel on the black separator strip which is on top of the 305mm 
high glass base panels. This bevelling action allows the glass to tuck underneath the gutter canopy. Use the capping and the self tapping 
screws to then hold the glass in place. The covers then enclose the screw heads giving a neat finish. It is a good idea to glaze two roof sections 
first to ensure the building is square followed by two side sections to ensure the building isn't leaning. We would then recommend that you 
glaze the porch roof and its adjoining angled roof panes whilst the building still has some movement in it.  
 
The porch cowling ‘DV341’ should be attached before the vents are inserted so that access through vent apertures is available. Silicone the 
cowling area internally, position cowl and VERY carefully (avoiding glass below) mark, drill and screw x 2 ‘FS6018’ into place. IMPORTANT: 
Silicone the cowling externally and check with watering can than the cowl is water tight, note silicone can be moulded shortly after application if 
you wet your fingers.   
 
IMPORTANT: On the roof sections please make sure that you place a screw around 25mm / 1” from the bottom of each capping strip (create a 
hole in the plastic if required) and that the screws are nice and tight to avoid any glass slippage.  

10 

VENT  

ATTACHMENT 

Take the assembled vent and slide the vent hinge ‘D866’ into the end of the ridge allowing the vent to pivot open and closed. Vent stops go 
either side of the vent to stop any lateral movement (so insert stop / vent / stop). Attach the Bayliss XL autovents.  

11 

DOOR  

ATTACHMENT 

Your door comes pre-constructed and locked minus the handles and their pivot pin but now it needs to be mounted to the front end of your 
building. Utilise the ‘DV522’ plates and twist in crop headed bolts to join the door and its frame to the building (pinch the door frame against 
your long front verticals whilst tightening your ‘DV522’ plates to ensure that there is no gap). If you are struggling to eradicate the gap between 
the door frame and verticals then some silicone can be carefully applied to the area to create a vertical seal. Be careful not to lock yourself in 
the building and to avoid damage do not open the door until it is attached to the front gable. Getting the door to swing perfectly without dropping 
or rubbing on the ground may require some small but vital adjustments. You may also need to insert a packer underneath the door frame hinge 
to increase ground clearance. Part ‘DV275’ canopies the door frame top hiding the clearance space at the top of the door. The door can only be 
made to swing inwards.  
 
IMPORTANT: Please do NOT let the door slam open or closed as it is likely to cause damage to the door and the frame. Please twist the han-
dle to open and close. Please also be aware that your door KEYS (3 provided) are unique to the building so they should not be stored together.  

12 

ANCHORING 

DOWN 

Now that the greenhouse is finished and the door and vent/s are operating without interference then you need to anchor the building down 
using 2” rawl plugs and screws. Use a 7mm masonry bit in a hammer drill to create the holes. 

13 

FINISHING 

TOUCHES 

Now that the main body of the structure is complete you can add; downpipe fittings, eave bungs, gutter stop ends. It is also important to care-
fully apply some silicone to the internal eaves corners and external and internal ridge corners to minimise the chance of water entering the 
structure. 

14 

OPTIONAL 

REAR 

SHELVING 

Robinsons integral cantilever staging and shelving attaches to the inside of the greenhouse frame using either square head bolts (insert four 
into each side glazing bar ’D066’ during construction of the rear (1)) or rectangular ‘crop head’ bolts which can be fitted retrospectively (both 
sets of bolts accompany the shelving/staging). This system allows the height of either the staging or the shelf to be set at an operator specific 
height. Commonly the staging brackets are set 900mm from the cills though you can alter this to suit the end user/s. The aluminium shelf / 
staging slats come in two lengths; (4’):1240mm ‘D2002’ and (6’):1860mm ’D2003’. These slats can combine to create any length of staging 
required, i.e. 4’+6’ = 10’ etc...     

15 

OPTIONAL 

REAR 

STAGING 

2 /

3  

Summary of Contents for Victorian ROOKLEY 14 Series

Page 1: ...NOMINAL SIZE A mm B mm 14 x 8 4486 2632 14 x 16 5112 14 x 24 7592 14 x 32 10072 ...

Page 2: ...u choose as flat and level an area as possible A concrete or slabbed base will provide the most solid foundation for your greenhouse IMPORTANT Do not fix your building down until the building is fully assembled including glazing Avoid placing your greenhouse under trees or in other vulnerable locations To minimise the risk of wind damage try to select as sheltered a site as possible e g beside a h...

Page 3: ... beneath the autovent will be attached to it later on 10 8 LOUVRE They attach to the building during the glazing process 9 like a piece of glass with a black separator above and below them If you are fitting an optional auto louvre then you need to carefully drill 3mm bit out the rivets which mount the handle to the frame You can then either utilise those holes or create more to mount the unit 9 G...

Page 4: ...Ref Part No Section Size mm 14 8 MAIN FRAME QUANTITIES VENTS DOORS etc SEPERATE Part No 14 8 SYBOL M6X11 10mm 133 SYBOL M6X11 CROP 10mm 20 SYBOL M6X15 15mm 61 SYBOL M6X22 22mm 22 SYBOL M6X22 CROP 22mm 8 SYNUTM6 M6 NUT 236 2 FS6018 19mm DV224L 540 1 DV224R 1 D048 1676 2 DV233L 2173 1 DV233R 1 DV269 468 2 DV290 1679 2 DV250L 1345 1 DV250R 1 D671 610 1 DV275 904 1 D163 90 2 DV104 N A 2 DV105 N A 1 RU...

Page 5: ...L R 2021 2 2 3 DV637L R 2489 2 2 3 DV639L R 2960 2 2 6 DV653 1378 2 6 DV655 1880 3 3 DV662 3395 2 6 DV675L R 863 1 1 6 DV687L R 1365 1 1 2 3 D813 1675 6 1 4 D834 1660 6 6 D871 601 4 6 DV652 1871 4 6 DV650 1345 2 6 D619 1144 1 2 D666 602 1 1 4 D825 1660 15 2 3 D826 1677 6 11 DV480 1384 1 2 DV634L R 2173 1 1 3 DV636L R 2021 2 2 3 DV638L R 2489 2 2 3 DV640L R 2960 2 2 6 DV656 1378 4 6 DV658 2481 7 3 ...

Page 6: ...It is essential that the BASE IS FLAT LEVEL AND SQUARE AS WELL AS BEING SUBSTANTIAL enough to take the weight of the greenhouse including its 4mm glass Give yourself enough room around your base to allow for fitting the glass and any on going maintenance cleaning A slab base which is larger than the greenhouse is the ideal solution and is our preferred foundation A brick perimeter base is equally ...

Page 7: ...on The frame is assembled by feeding square headed bolts either 10mm 15mm or 22mm in length into the slots on glazing bars and then locating those bolts through holes in purlings and cills etc Twist in rectangular crop headed bolts are also used towards the end of construction to attach components to the frame when the glazing bar slots are no longer ex posed at the ends 10mm 15mm PARTITION ONLY R...

Page 8: ...t No mm Quantity DV210 2517 1 D021 2514 1 D066 1676 3 D103 1787 2 D174 2 SYBOL M6X11 3 SYBOL M6X15 5 SYBOL M6X22 6 SYNUT M6 8 D227 Rubber 1000 11 8 DV210 D021 15mm 10mm 22mm 22mm 15mm 10mm 22mm 22mm 15mm 10mm 22mm 22mm ...

Page 9: ...9 D103 D103 15mm D066 10mm D066 TRANSIT BOLT ON DIAGONALS 15mm 22mm ...

Page 10: ... R 10mm 10mm 15mm 10mm 10mm Part No mm Quantity D671 610 1 D048 1676 2 DV224L 540 1 DV224R 540 1 DV233L 2173 1 DV233R 2173 1 DV250L 1345 1 DV250R 1345 1 PORCH GABLE Part No mm Quantity DV269 468 2 DV275 904 1 DV290 1679 2 DV104 2 DV105 1 D163 2 D174 4 D227 Rubber 1000 20 SYBOL M6X11 28 SYBOL M6X15 8 SYNUT M6 36 DV224L DV224R DV269 DV269 DV275 D671 ...

Page 11: ... DV224L DV224R DV224L DV224R D174 DV290 DV250L DV250R D048 DV105 D671 DV233L DV233R DV250L DV250R DV233L DV233R DV233L DV233R DV275 D163 D048 DV290 DV250L DV250R DV269 DV104 DV104 DV250L DV250R FLIP VIEW ...

Page 12: ...rt No mm Quantity D174 14 M6X10 66 M6X15 26 M6NUT 92 DV104 4 D227 98m DV105 2 DV268 964 2 DV274 3402 2 DV292 1794 4 DV232 D048 10mm 10mm 10mm 10mm 15mm 15mm D048 D V 2 9 2 D V 2 9 2 DV237R DV262 DV274 D V 2 5 2 R 15mm 15mm 15mm 15mm 10mm 10mm 10mm 10mm DV235R DV235L 10mm 15mm 10mm 10mm 10mm 15mm 10mm 10mm DV252L DV239L DV239R DV237L 10mm 15mm 10mm 10mm 10mm 15mm DV268 10mm 15mm 10mm 10mm ...

Page 13: ...13 DV252L DV232 D174 DV292 DV232 DV252R D048 DV105 DV262 DV237L DV237R DV252L DV252R DV237L DV237R DV235L DV235R D048 DV292 DV252L DV252R DV274 DV104 DV104 DV252L DV252R FLIP VIEW ...

Page 14: ...923 1 DV357 923 1 DV361 303 1 DV362 1676 2 DV394 327X947 1 DV395 1 D174 4 D227 Rubber 1000 14 SYBOL M6X11 8 SYBOL M6X15 4 SYBOL M6X22 4 SYNUT M6 12 D06 6 D0 66 DV 362 DV362 DV348 DV357 DV394 DV395 D V 3 4 5 22mm DV361 10mm 10mm 15mm 15mm 10mm 22mm 22mm 15mm 10mm 10mm 10mm ...

Page 15: ...15 EQUAL ...

Page 16: ...ending on your ridge length a half cresting may need to be cut Some spacer bar may also be required DV281 cut into two equal sections Each finial and cresting piece needs to be siliconed D119 into place 1 REAR ROOF 14x8 Part No mm Quantity DV100 n a 5 DV201 2517 1 DV255 2450 3 D227 Rubber 1000 15 SYBOL M6X11 6 SYBOL M6X22 12 SYNUT M6 22 1 ...

Page 17: ...17 2 DV255 D066 3 DV255 22mm 22mm DV100 3 2 4 10mm 10mm 4 4 ...

Page 18: ...365 899 1 DV375L 830 1 DV375R 830 1 DV378L 2368 1 DV378R 2368 1 DV380 n a 1 DV381 1668 2 DV389 1105 1 D227 Rubber 1000 21 SYBOL M6X11 22 SYBOL M6X22 18 SYNUT M6 46 DV253 DV395 DV361 DV348 DV345 DV381 D066 DV357 DV394 DV382L DV382R DV389 DV375R DV375L DV362 DV380 DV101 DV350 DV100 DV365 D982 ...

Page 19: ...ate the chance of any leaks the holes circled above can vary slightly in their locations They may therefore require slight alteration to marry up with DV363 and DV379 Using an 8mm drill bit to enlarge the standard 7mm holes will for example give a little more play to aid fitting DV380 DV365 D982 FS6006 FS6504 FLIP VIEW ...

Page 20: ...D863L D866 639 1 D863L 613 1 D863R 613 1 D862 593 1 Part No mm Quantity D220 PLUS SCREW N A 2 D205 N A 2 SYBOL M6X11 10 4 SYNUT M6 M6 4 8 X 12 S T FS6017 10 2 Part No mm Quantity 8 x 19 S T FS6018 19 2 D863R D866 2 2 D1208 1 of 610 x 610 pane ...

Page 21: ...21 D862 D862 D863L 2 2 2 2 2 FLIP VIEW D119 CUT 6mm SILICONE ...

Page 22: ...22 D114 D079 FLIP VIEW D079 PLUS FLUFF 590 1 D114 N A 2 Part No mm Quantity SY BOLM6X11 10 2 SY BOLM6X15 15 2 SYBOLM6 X11CROP 10 2 SYNUTM6 N A 4 Part No mm Quantity D114 ...

Page 23: ... D168L D168R handle 552 552 1 1 D165 612 2 D166 552 2 FS6013 12 4 Part No mm Quantity INTERNAL VIEW D165 D165 D166 D166 D168L D168R D165 PINCH ALL GLASS RETAINERS BEFORE GLAZING D729TG 100 x 525 panes x 6 ...

Page 24: ...cking that all is present and correct You can also place the roof cappings in the gutters so they are closer to hand If you have a building which has aluminium cover caps then the roof covers are held in place with low profile countersunk screws FS6020 It looks neatest if all of these screws go towards the ridges of the building see right FS6020 PORCH CAPS AND COVERS 14x8 PART No SECTION SIZE mm Q...

Page 25: ...25 DV679L DV675L DV688L D870 DV687L DV688R D870 DV687R D619 D870 D823 DV679R DV675R DV634L DV633L DV634R DV633R D825 D812 DV656 DV650 D826 D813 D666 D662 DV656 DV653 DV480 DV479 ...

Page 26: ...d any glass slippage S B D825 D812 125 PORCH GLASS 14x8 PART No Size mm QUANTITY D729TG L 525 X 100 12 D770 F 457 X 305 14 D771 G 457 X 1374 14 D904 N 305 X 1374 4 D905 Q 305 X 305 4 D906 M 610 X 762 2 D1206 S 610 X 1374 4 D1208 A 610 X 610 9 D1254 B 610 X 305 6 DV507 P ANGLE 4 DV700 D 357 X 1384 2 DV706 U 610 X 1384 2 DV710 C ANGLE 2 DV712 H ANGLE 2 DV713 K ANGLE 4 DV714 J ANGLE 4 DV716 T ANGLE 4...

Page 27: ...M M R R R R A A L L A A SILICONE D119 DV341 FS6018 Using DV341 as a template mark and carefully drill a Ø3mm hole through each side of the porch ridge avoiding surrounding glass Silicone to waterproof area G G D D S C C H H A A A A A X Y Y X O U Z ROOF PANES OVERLAP B B B B ...

Page 28: ...28 D220 D220 ...

Page 29: ...29 D079 D862 ...

Page 30: ...30 DV495 DV499 DV498 DV494 DV497 DV496 DV495 DV495 DV499 DV500 DV700 DV700 DV478 DV480 DV479 ...

Page 31: ...31 Part No Quantity D522 10 SYBOLM6 X11CROP 20 SYNUTM6 20 DV522 DV275 ...

Page 32: ...32 O7mm ...

Page 33: ...33 D841 D211 D211 D201 D119 S I L I C O N E D214 D048 D208 CUT D048 D207 DV218LH DV219RH DV219 SHOWN DV219 SHOWN D119 SILICONE DV120 D048 DV280 D119 S I L I C O N E ...

Page 34: ...34 DV101 Part No Quantity SYBOLM6 X22CROP 8 SYNUTM6 8 ...

Page 35: ...35 D2021 15mm 10mm crop 10mm 10mm D2013 D2014 D2014 crop 10mm D2002 1240mm D2003 1860mm D2002 1240mm Example 2x 4 3 slat shelves ST0304 8 run D066 D048 D048 ...

Page 36: ...lat staging ST0704 8 run 10mm 10mm D2044 D2043 D2045 D2045 D2044 D2043 D2046 D2046 D2047 D2042 D2042 D2042 crop 10mm 10mm 10mm 10mm crop 10mm START FINISH D2002 1240mm D2002 1240mm D2002 1240mm D2003 1860mm D066 D048 D048 ...

Page 37: ...01004 8 run D2045 D2045 D2043 D2049 D2050 D2050 10mm crop 10mm START D2002 1240mm D2002 1240mm D2003 1860mm 10mm 10mm FINISH D2048 D2044 D2048 D2050 10mm 10mm D2044 D174 D2052 D174 D2051 D2043 crop 10mm D2002 1240mm D2052 D048 D066 D048 ...

Page 38: ...38 ...

Page 39: ...39 ...

Page 40: ...be aware that this is a new multi national manual If you spot any errors or have any constructive comments regarding the manual please email james spooner greenhousepeople co uk and I will make the necessary amendments In addition any photographs of completed buildings would be most appreciated to add to our portfolio THIS GREENHOUSE BOX WAS PACKED BY DATE ___________________ _____________________...

Reviews: