background image

  

NOMINAL  

SIZE 

A (mm)  B (mm) 

14 x 8 

 
 
 

4486 

2632 

14 x 16 

5112 

14 x 24 

7592 

14 x 32 

10072 

Summary of Contents for Victorian ROOKLEY 14 Series

Page 1: ...NOMINAL SIZE A mm B mm 14 x 8 4486 2632 14 x 16 5112 14 x 24 7592 14 x 32 10072 ...

Page 2: ...u choose as flat and level an area as possible A concrete or slabbed base will provide the most solid foundation for your greenhouse IMPORTANT Do not fix your building down until the building is fully assembled including glazing Avoid placing your greenhouse under trees or in other vulnerable locations To minimise the risk of wind damage try to select as sheltered a site as possible e g beside a h...

Page 3: ... beneath the autovent will be attached to it later on 10 8 LOUVRE They attach to the building during the glazing process 9 like a piece of glass with a black separator above and below them If you are fitting an optional auto louvre then you need to carefully drill 3mm bit out the rivets which mount the handle to the frame You can then either utilise those holes or create more to mount the unit 9 G...

Page 4: ...Ref Part No Section Size mm 14 8 MAIN FRAME QUANTITIES VENTS DOORS etc SEPERATE Part No 14 8 SYBOL M6X11 10mm 133 SYBOL M6X11 CROP 10mm 20 SYBOL M6X15 15mm 61 SYBOL M6X22 22mm 22 SYBOL M6X22 CROP 22mm 8 SYNUTM6 M6 NUT 236 2 FS6018 19mm DV224L 540 1 DV224R 1 D048 1676 2 DV233L 2173 1 DV233R 1 DV269 468 2 DV290 1679 2 DV250L 1345 1 DV250R 1 D671 610 1 DV275 904 1 D163 90 2 DV104 N A 2 DV105 N A 1 RU...

Page 5: ...L R 2021 2 2 3 DV637L R 2489 2 2 3 DV639L R 2960 2 2 6 DV653 1378 2 6 DV655 1880 3 3 DV662 3395 2 6 DV675L R 863 1 1 6 DV687L R 1365 1 1 2 3 D813 1675 6 1 4 D834 1660 6 6 D871 601 4 6 DV652 1871 4 6 DV650 1345 2 6 D619 1144 1 2 D666 602 1 1 4 D825 1660 15 2 3 D826 1677 6 11 DV480 1384 1 2 DV634L R 2173 1 1 3 DV636L R 2021 2 2 3 DV638L R 2489 2 2 3 DV640L R 2960 2 2 6 DV656 1378 4 6 DV658 2481 7 3 ...

Page 6: ...It is essential that the BASE IS FLAT LEVEL AND SQUARE AS WELL AS BEING SUBSTANTIAL enough to take the weight of the greenhouse including its 4mm glass Give yourself enough room around your base to allow for fitting the glass and any on going maintenance cleaning A slab base which is larger than the greenhouse is the ideal solution and is our preferred foundation A brick perimeter base is equally ...

Page 7: ...on The frame is assembled by feeding square headed bolts either 10mm 15mm or 22mm in length into the slots on glazing bars and then locating those bolts through holes in purlings and cills etc Twist in rectangular crop headed bolts are also used towards the end of construction to attach components to the frame when the glazing bar slots are no longer ex posed at the ends 10mm 15mm PARTITION ONLY R...

Page 8: ...t No mm Quantity DV210 2517 1 D021 2514 1 D066 1676 3 D103 1787 2 D174 2 SYBOL M6X11 3 SYBOL M6X15 5 SYBOL M6X22 6 SYNUT M6 8 D227 Rubber 1000 11 8 DV210 D021 15mm 10mm 22mm 22mm 15mm 10mm 22mm 22mm 15mm 10mm 22mm 22mm ...

Page 9: ...9 D103 D103 15mm D066 10mm D066 TRANSIT BOLT ON DIAGONALS 15mm 22mm ...

Page 10: ... R 10mm 10mm 15mm 10mm 10mm Part No mm Quantity D671 610 1 D048 1676 2 DV224L 540 1 DV224R 540 1 DV233L 2173 1 DV233R 2173 1 DV250L 1345 1 DV250R 1345 1 PORCH GABLE Part No mm Quantity DV269 468 2 DV275 904 1 DV290 1679 2 DV104 2 DV105 1 D163 2 D174 4 D227 Rubber 1000 20 SYBOL M6X11 28 SYBOL M6X15 8 SYNUT M6 36 DV224L DV224R DV269 DV269 DV275 D671 ...

Page 11: ... DV224L DV224R DV224L DV224R D174 DV290 DV250L DV250R D048 DV105 D671 DV233L DV233R DV250L DV250R DV233L DV233R DV233L DV233R DV275 D163 D048 DV290 DV250L DV250R DV269 DV104 DV104 DV250L DV250R FLIP VIEW ...

Page 12: ...rt No mm Quantity D174 14 M6X10 66 M6X15 26 M6NUT 92 DV104 4 D227 98m DV105 2 DV268 964 2 DV274 3402 2 DV292 1794 4 DV232 D048 10mm 10mm 10mm 10mm 15mm 15mm D048 D V 2 9 2 D V 2 9 2 DV237R DV262 DV274 D V 2 5 2 R 15mm 15mm 15mm 15mm 10mm 10mm 10mm 10mm DV235R DV235L 10mm 15mm 10mm 10mm 10mm 15mm 10mm 10mm DV252L DV239L DV239R DV237L 10mm 15mm 10mm 10mm 10mm 15mm DV268 10mm 15mm 10mm 10mm ...

Page 13: ...13 DV252L DV232 D174 DV292 DV232 DV252R D048 DV105 DV262 DV237L DV237R DV252L DV252R DV237L DV237R DV235L DV235R D048 DV292 DV252L DV252R DV274 DV104 DV104 DV252L DV252R FLIP VIEW ...

Page 14: ...923 1 DV357 923 1 DV361 303 1 DV362 1676 2 DV394 327X947 1 DV395 1 D174 4 D227 Rubber 1000 14 SYBOL M6X11 8 SYBOL M6X15 4 SYBOL M6X22 4 SYNUT M6 12 D06 6 D0 66 DV 362 DV362 DV348 DV357 DV394 DV395 D V 3 4 5 22mm DV361 10mm 10mm 15mm 15mm 10mm 22mm 22mm 15mm 10mm 10mm 10mm ...

Page 15: ...15 EQUAL ...

Page 16: ...ending on your ridge length a half cresting may need to be cut Some spacer bar may also be required DV281 cut into two equal sections Each finial and cresting piece needs to be siliconed D119 into place 1 REAR ROOF 14x8 Part No mm Quantity DV100 n a 5 DV201 2517 1 DV255 2450 3 D227 Rubber 1000 15 SYBOL M6X11 6 SYBOL M6X22 12 SYNUT M6 22 1 ...

Page 17: ...17 2 DV255 D066 3 DV255 22mm 22mm DV100 3 2 4 10mm 10mm 4 4 ...

Page 18: ...365 899 1 DV375L 830 1 DV375R 830 1 DV378L 2368 1 DV378R 2368 1 DV380 n a 1 DV381 1668 2 DV389 1105 1 D227 Rubber 1000 21 SYBOL M6X11 22 SYBOL M6X22 18 SYNUT M6 46 DV253 DV395 DV361 DV348 DV345 DV381 D066 DV357 DV394 DV382L DV382R DV389 DV375R DV375L DV362 DV380 DV101 DV350 DV100 DV365 D982 ...

Page 19: ...ate the chance of any leaks the holes circled above can vary slightly in their locations They may therefore require slight alteration to marry up with DV363 and DV379 Using an 8mm drill bit to enlarge the standard 7mm holes will for example give a little more play to aid fitting DV380 DV365 D982 FS6006 FS6504 FLIP VIEW ...

Page 20: ...D863L D866 639 1 D863L 613 1 D863R 613 1 D862 593 1 Part No mm Quantity D220 PLUS SCREW N A 2 D205 N A 2 SYBOL M6X11 10 4 SYNUT M6 M6 4 8 X 12 S T FS6017 10 2 Part No mm Quantity 8 x 19 S T FS6018 19 2 D863R D866 2 2 D1208 1 of 610 x 610 pane ...

Page 21: ...21 D862 D862 D863L 2 2 2 2 2 FLIP VIEW D119 CUT 6mm SILICONE ...

Page 22: ...22 D114 D079 FLIP VIEW D079 PLUS FLUFF 590 1 D114 N A 2 Part No mm Quantity SY BOLM6X11 10 2 SY BOLM6X15 15 2 SYBOLM6 X11CROP 10 2 SYNUTM6 N A 4 Part No mm Quantity D114 ...

Page 23: ... D168L D168R handle 552 552 1 1 D165 612 2 D166 552 2 FS6013 12 4 Part No mm Quantity INTERNAL VIEW D165 D165 D166 D166 D168L D168R D165 PINCH ALL GLASS RETAINERS BEFORE GLAZING D729TG 100 x 525 panes x 6 ...

Page 24: ...cking that all is present and correct You can also place the roof cappings in the gutters so they are closer to hand If you have a building which has aluminium cover caps then the roof covers are held in place with low profile countersunk screws FS6020 It looks neatest if all of these screws go towards the ridges of the building see right FS6020 PORCH CAPS AND COVERS 14x8 PART No SECTION SIZE mm Q...

Page 25: ...25 DV679L DV675L DV688L D870 DV687L DV688R D870 DV687R D619 D870 D823 DV679R DV675R DV634L DV633L DV634R DV633R D825 D812 DV656 DV650 D826 D813 D666 D662 DV656 DV653 DV480 DV479 ...

Page 26: ...d any glass slippage S B D825 D812 125 PORCH GLASS 14x8 PART No Size mm QUANTITY D729TG L 525 X 100 12 D770 F 457 X 305 14 D771 G 457 X 1374 14 D904 N 305 X 1374 4 D905 Q 305 X 305 4 D906 M 610 X 762 2 D1206 S 610 X 1374 4 D1208 A 610 X 610 9 D1254 B 610 X 305 6 DV507 P ANGLE 4 DV700 D 357 X 1384 2 DV706 U 610 X 1384 2 DV710 C ANGLE 2 DV712 H ANGLE 2 DV713 K ANGLE 4 DV714 J ANGLE 4 DV716 T ANGLE 4...

Page 27: ...M M R R R R A A L L A A SILICONE D119 DV341 FS6018 Using DV341 as a template mark and carefully drill a Ø3mm hole through each side of the porch ridge avoiding surrounding glass Silicone to waterproof area G G D D S C C H H A A A A A X Y Y X O U Z ROOF PANES OVERLAP B B B B ...

Page 28: ...28 D220 D220 ...

Page 29: ...29 D079 D862 ...

Page 30: ...30 DV495 DV499 DV498 DV494 DV497 DV496 DV495 DV495 DV499 DV500 DV700 DV700 DV478 DV480 DV479 ...

Page 31: ...31 Part No Quantity D522 10 SYBOLM6 X11CROP 20 SYNUTM6 20 DV522 DV275 ...

Page 32: ...32 O7mm ...

Page 33: ...33 D841 D211 D211 D201 D119 S I L I C O N E D214 D048 D208 CUT D048 D207 DV218LH DV219RH DV219 SHOWN DV219 SHOWN D119 SILICONE DV120 D048 DV280 D119 S I L I C O N E ...

Page 34: ...34 DV101 Part No Quantity SYBOLM6 X22CROP 8 SYNUTM6 8 ...

Page 35: ...35 D2021 15mm 10mm crop 10mm 10mm D2013 D2014 D2014 crop 10mm D2002 1240mm D2003 1860mm D2002 1240mm Example 2x 4 3 slat shelves ST0304 8 run D066 D048 D048 ...

Page 36: ...lat staging ST0704 8 run 10mm 10mm D2044 D2043 D2045 D2045 D2044 D2043 D2046 D2046 D2047 D2042 D2042 D2042 crop 10mm 10mm 10mm 10mm crop 10mm START FINISH D2002 1240mm D2002 1240mm D2002 1240mm D2003 1860mm D066 D048 D048 ...

Page 37: ...01004 8 run D2045 D2045 D2043 D2049 D2050 D2050 10mm crop 10mm START D2002 1240mm D2002 1240mm D2003 1860mm 10mm 10mm FINISH D2048 D2044 D2048 D2050 10mm 10mm D2044 D174 D2052 D174 D2051 D2043 crop 10mm D2002 1240mm D2052 D048 D066 D048 ...

Page 38: ...38 ...

Page 39: ...39 ...

Page 40: ...be aware that this is a new multi national manual If you spot any errors or have any constructive comments regarding the manual please email james spooner greenhousepeople co uk and I will make the necessary amendments In addition any photographs of completed buildings would be most appreciated to add to our portfolio THIS GREENHOUSE BOX WAS PACKED BY DATE ___________________ _____________________...

Reviews: