4
Part
No.
Section Size
(mm)
6’
EX
8’
EX
STANDARD LEFT HAND SIDE
EXTENSION
D029L
1860 1
D024L 2480
1
D028L 1860
1
D017L 2480
1
D138
1167 1
D131
D673
D784
STAN./
DWARF /
REACH
1630
1114
1930
1
1
1
D146
N/A 2
D158
N/A 1
D114
N/A
1
Part
No.
Section Size
(mm)
6’
EX
8’
EX
STANDARD RIGHT HAND SIDE
EXTENSION
D029R
1860 1
D024R 2480
1
D028R 1860
1
D017R 2480
1
D138
1167 1
D131
D673
D784
STAN./
DWARF /
REACH
1630
1114
1930
1
1
1
D146
N/A 2
D158
N/A 1
D114
N/A
1
STANDARD FREESTANDING
RIDGE EX.
D027
1860
1
D004
2480 1
D157
N/A
1
D135
926 1
D132
1010 2
REGENT ROOF
D136
1546 1
D133
1352 2
ROYALE ROOF
D137
2176 1
D134
1700 2
ROSETTE ROOF
D139
2786 1
D140
2039 2
REGAL ROOF
REAR
FREE-STANDING ROBINSONS EXTENSIONS VERY IMPORTANT INFORMATION:
If you have been supplied with an extension (i.e. your building is longer than 12’), your main building will differ in that the roof end and corner glazing
bars (on the end to which the extension will be fitted) are replaced with standard side and roof glazing bars from the extension module kit. These
should be fitted using 15mm bolts. In addition, it will be necessary to slide additional 10mm bolts into each side bar and roof bars (5 for Rosette &
Regal, 4 for Royale, & 3 for Regent) to accommodate a reinforcing channel (10mm bolts must be used here, 15mm bolts will get in the way when
fitting the square a-frame tubing). You only need four side diagonal braces per building (two each side), move the two (currently on main sides) near-
est the extension join towards the rear.
Be careful not to mix up your extension cills and gutters. There will be a separate gutter and cill for the left and right side extensions.
In
addition one set of holes in both the gutter, cill, and ridge sections are slightly closer together (
586mm instead of 620mm
). When fitting the extension
ridge, gutters and side cills, the 586mm hole centres at one end of the extension components must abut the main greenhouse. Each of the extension
joining plates should be initially attached to the main building and then onto the 586mm spaced hole end of each extension section.
IMPORTANT:
Each glazing bar centre should then be
620mm apart
. If not your glass will not fit properly. See next pages 6 and 7 for more details.
FS6006
FS6504
35mm
M6 S/S
6
6
SYBOLM6X11
10mm
50
SYBOLM6X15
15mm
40
SYNUTM6
M6
90
RENOWN ROOF
D139
2786 1
D736
2384 2
D962
A
1890 2
Due to its width the 14’ wide Renown
model has extra roof purlings to add
even more strength. Extended Re-
nown models have an A-frame every
6’. The roof purlings ‘D962A’ need to
be notched at the ends to allow for the
tabbed ends to tuck between the roof
bar ‘D737’ and reinforcing channel
’D736’. The purlings do not need to fit
in one continuous line they can be
stepped above or below one another.
FRONT