
2
IMPORTANT NOTES
1.
This fire is for use on Natural Gas only and cannot be used on any other gas. "CE marked" for use in the United Kingdom and
Eire.
2.
This fire must be installed and serviced regularly in accordance with the current Gas Safety (Installation and Use) Regulations
by a competent person i.e. Gas Safe registered Engineer. Where solid fuel has been used the chimney must be swept
before installation. The fire must be installed in accordance with the installation instructions, and the rules in force.
3.
It is recommended that at least once a year the appliance should be removed to check the catchment space and the chimney
for debris by a Gas Safe registered Engineer. The fire should be checked annually to ensure continued clearance of
products and that there is no excessive build up of powdery substances.
4.
DRESSGUARD: The glass window on this appliance conforms to the requirements of BS 1945 : 1991 and satisfies the heating
Appliances (Fireguards) Regulations 1991.
IT DOES NOT GIVE FULL PROTECTION FOR YOUNG CHILDREN, THE ELDERLY OR THE INFIRM!
A fireguard conforming to
B.S. 8423 (Fireguards for heating appliances for domestic use) should be used for the protection
of children, the elderly or the infirm. Such a guard is also recommended for pet animals
.
WARNING: The glass panel is of a special heat resisting type and if damaged the glass window must be replaced with the
proper spare (G.C. No. 159 674) DO NOT USE THE FIRE WITH DAMAGED GLASS.
5.
After the fire has been installed you may wish to fix a shelf above. This is quite acceptable provided the underside of a
combustible shelf is at least 150mm above the fire and does not project more than 150mm forward. For a deeper shelf allow
13mm increase in shelf height for every 25mm increase in depth.
6.
Do not burn paper or any rubbish in the fire.
7.
Clothes etc. must not be draped over the fire. The convection outlet must never be obstructed by hanging towels etc.
8.
When the fire is first used some slight smoke and smell may be given off but this will will clear after a few hours of use at the
full on rate (Setting No. 4). Condensation on the window inner surface is normal, when the heater is lit from cold.
9.
IMPORTANT: When considering fitting any heating appliance or wallpapering a room in which one is fitted if blown vinyl or heat
sensitive wallpapers (or soft furnishings) are used in the vicinity of the heat source then they may become heat damaged or
discoloured especially just above the fire.
10. It is important for safe operation and to maintain efficiency that the fire is not operated with a damaged or broken coal bed.
IMPORTANT: Under no circumstances should any loose coals be purchased and used on the coal bed. The fire has a
specially designed coal bed and only this must be used.
11.
WARNING: If the flames are found to be extinguished and the control knob is not in the OFF position, the control knob must be
turned to the OFF position and no attempt should be made to light the fire for 3 minutes.
NOTE: The control knob is situated on the top right hand side of the fire and is marked with the symbols OFF, , 1, 2, 3, 4. The
ignition spark generator, battery powered (size AA), is located at the lower rear RH side.
LIGHT THE FIRE
Depress the control knob and turn it anticlockwise to the (pilot) position. Depress the control knob, sparks will be heard and the
pilot should light which can be seen in the lower centre of the glass window on the fire. If the pilot did not light turn the control knob
to OFF and try again. hen the pilot has lit keep the knob depressed for a further 10 seconds to activate the flame supervision
device otherwise the pilot will go out again. Once the pilot is established turn the control knob to the desired setting.
The control knob is connected to the gas tap by a universal coupling and will have a ‘loose feel’ to it, which should not cause
concern.
CONTROL SETTING 1
-
the centre burner section is on at a low rate.
CONTROL SETTING 2
-
the centre burner section is on at a high rate.
CONTROL SETTING 3
-
the centre burner is on high and the outer burner sections are on at a low rate.
CONTROL SETTING 4
-
all burner sections are on full rate.
TO TURN OFF depress the control knob slightly and turn clockwise to the OFF position.
NOTE: If you want to relight a hot fire wait 5 minutes before doing so.
This product uses fuel effect pieces containing Refractory Ceramic Fibre (RCF), which are man-made vitreous silicate
fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract,
consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a
minimum.
W
TO LIGHT AND OPERATE