Schedule Settings – Defaults
This thermostat is preprogrammed with a schedule that is recommended
by EnergyStar™. The schedule is designed to lower energy costs
year-round.
The default schedule settings are:
Time
Cooling °F
Heating °F
Morn
6:00 am
78
70
Day
8:00 am
85
62
Eve
6:00 pm
78
70
Nite
10:00 pm
82
62
User Settings – Defaults
During any program changes the display returns back to the operating
display if a button has not been pushed in 10 seconds.
The temperature scale is set to Fahrenheit.
Night light is on.
The first stage differential is 1 °F.
The second stage differential is 2 °F.
The second stage delay is 20 minutes.
Auto changeover is enabled.
Auto changeover deadband is 3 °F.
Filter reminder length is off.
Temperature offset is 0 degrees.
The HI heat limit is 90 °F (32 °C).
The LO cool limit is 45 °F (7 °C)
The vacation temperature settings are set at: heating 60°F, cooling 85 °F.
The operation mode is OFF.
The fan setting is Auto.
The keypad has no password protection.
Refer to the pop up wizard section in the installation manual for a
complete list of factory defaults and contractor settings.
Emergency Heat
Your system may include Emergency Heat. The RS5220C thermostats
have an emergency heat capability for multi stage heat pump systems.
To determine if your system is capable of using emergency heat contact
your contractor. Use the
button to enter the EMER mode. An E will
be displayed with the Heat symbol. This mode is used to bypass the
heat pump when it needs servicing or when it cannot keep up with the
heat demand.