Robertshaw RS2210 Series Owner'S Manual Download Page 3

Energy Monitor

• The Energy Monitor feature measures

and stores the amount of time the 

heating and air conditioning system

operates. Usage can be displayed for Today (since

12 am), Yesterday, This Week (since Monday), Last

Week (last Monday through Sunday), and Total (up

to 999 hours). By monitoring your energy usage,

you see how much the set-back periods are sav-

ing. To review energy usage, press to cycle through

Today, Yesterday, this Week, Last Week, and Total.

Press again to return to normal mode, or wait 15

seconds for the display to return to normal mode.

You also can return to normal mode at any time by

pressing RUN.

• For example: This LCD display shows Today’s usage to

be 10 Hours, 26 minutes.

• Press and hold for 3 seconds to reset the Energy

Monitor’s counters. The display will blink, and counters

will be cleared to zero.

NOTE:

Clearing the Energy Monitor counter will also clear

the Filter Monitor counter, as filter usage and total energy

usage are the same. Also, clearing the Filter Monitor 

counter will clear ALL Energy Monitor counters as well.

Filter Monitor

Your thermostat keeps a record of the number

of hours your filter has been in use. To maxi-

mize your system’s performance and energy

efficiency, change or clear your filter regularly.

• When the total system run time for heat and cool reaches

500 hours, you need to clean or change your system’s 

filter. FILT will continue to flash until the counter is set

back to zero.

• Press FILTER to review total filter usage. The

display will blink FILT, Then show the Filter

Monitor counter. After 15 seconds, the 

display will return to normal mode, or you can

hit RUN to exit immediately. 

The Filter Monitor will display up to 999 hours and 

59 minutes of usage. In this example, the counter is at

410 Hours, 26 minutes.

• To reset the Filter Monitor counter, depress FILTER for 

3 seconds. The display will blink and the counter will be

reset to zero.

NOTE:

Clearing the Filter Monitor counter also will clear

ALL Energy Monitor counters, as Filter usage and Total

Energy usage are the same. Also, clearing the Energy

Monitor counters will clear the Filter Monitor counter as

well.

Keyboard Lock 

The keyboard can be locked to prevent unauthorized

changes to the thermostat.

To lock or unlock the keyboard, press and hold

RUN key for 3 seconds. The keyboard is locked,

when LOCK appears on the display.

• When all keys are locked, LOCK will appear on the 

display for 1 second any time a key is pressed.

Backlighting

Your thermostat has an electroluminescent lamp that 

backlights the display for easy viewing in the dark.

When any key is pressed the display is illuminated.

The display will remain illuminated for 8 seconds after the

last key is pressed. This allows the light to stay on if you

need to operate several keys.

NOTE:

If the thermostat is in Low Battery warning 

condition, the backlight will not operate. Replace with 2

new AA alkaline batteries to restore the backlight function.

Low Battery Warning

Your thermostat has a two-stage low battery

warning system. When the batteries are first

detected to be weak, the first stage low battery

warning is indicated by BATT flashing on the

LCD display. At your earliest convenience, you

need to replace the batteries with 2 new AA

alkaline batteries.

When the batteries become too weak for normal operation,

the thermostat enters the second stage low battery warning

which shuts down the thermostat. In this condition, BATT

flashes alone on the display, and the thermostat will turn

your system off. Your system will remain off until the batter-

ies are replaced.

NOTE:

The thermostat will still keep the current set 

temperature and filter run time in memory until new 

batteries are installed. After confirming that new batteries

have been inserted, the thermostat will return to normal

operation.

Error Mode

If the thermostat is unable to control your system due to an

unexpected battery problem, the thermostat will enter Error

Mode. In this condition, the thermostat flashes E1, E2, E3

or E4 on the LCD display, and shuts off your system. To

correct this problem, replace the batteries with 2 new AA

alkaline batteries, even if you have recently replaced them.

Press the reset button once with a small pin and hold for

two seconds then reprogram. You will need to confirm 

normal operation.

If Error Mode returns, please call us for further information.

Warning Mode

If the Malfunction Input (L) from the heat pump is active, 

the thermostat flashes E5 on the LCD display. 

Auto Cut Off

Your thermostat will automatically shut down in Heat mode

if the room temperature rises above 95ºF (35ºC). It will shut

down in Cool mode if the room temperature drops below

40ºF (4ºC). Note that if your system has malfunctioned and

no longer responds to thermostat controls, the Auto Cut-Off

will have no effect.

Problem

SCRAMBLED OR
DOUBLE DISPLAY
(numbers over numbers)

NO DISPLAY

ENTIRE DISPLAY DIMS

AUTO/FAN DOES NOT
TURN ON

ERRATIC DISPLAY

IF UNIT CONTINUES TO
OPERATE IN THE OFF
POSITION

THERMOSTAT 
PERMANENTLY READS
E1, E2, E3, E4

Solution

1. Remove clear mylar sticker.

1. Check battery connections and

batteries.

2. Press the reset button once with a

small pin and hold for two seconds
then reprogram.

1. Replace batteries.

1. Move ELEC/GAS selector to oppo-

site position.

2. There may be as much as a 4

minute delay before the heat or
cool system turns on. Wait and
check.  (Compressor protection
delay)

3. Check your circuit breakers and

switches to ensure there is power
to the system.

4. Replace batteries.

5. Make sure your furnace blower

door is closed properly.

6. If your system only uses 4-wires,

be sure the jumper wire is installed
between the RC and RH terminals.

7. Check the position of the Furnace

or Heat Pump selector switches:
Normal/O/B.

Press the reset button once with a
small pin and hold for two seconds
then reprogram.

1. Replace unit.

1. Replace unit.

If you experience any other problems, contact Technical Support at:
www.invensyscontrols.com or (800) 445-8299

TROUBLESHOOTING

191 E. North Avenue
Carol Stream, Illinois  60188
www.invensyscontrols.com
©2007 Invensys Controls

352-00021-002 Rev A  8/07

Two Year Limited Warranty

Invensys Controls warrants to the original contractor installer
or to the original consumer user that each new Robertshaw
Product shall be free from defects in materials and workman-
ship under normal use and service for a period of two (2)
years from the date of manufacture (“Warranty Period”).
If any Product fails within the applicable Warranty Period,
Invensys Controls shall, at its sole option, repair or replace
the Product, provided that the Product is returned to
Invensys Controls’ facility or designated agent within the
Warranty Period, with transportation charges prepaid, and
that the Product, upon examination by Invensys Controls, is
found to conform to this warranty.  The above warranty does
not apply to: i) batteries; ii) improper installation; iii) Products
that have been damaged, misused, neglected, mishandled,
or altered in any manner whatsoever, and/or; iv) defects or
damage that result from use of the Product in other than its
normal and customary manner or in any manner not in
accordance with Invensys Controls’ recommendations
and/or instructions.  Any and all costs of labor, thermostat
removal, or reinstallation are not covered under this warranty
and shall be the sole responsibility of the consumer or
installer, as applicable.

THE FOREGOING WARRANTY IS IN LIEU OF AND
EXCLUDES ALL OTHER WARRANTIES, WHETHER VERBAL
OR WRITTEN, EXPRESS OR IMPLIED INCLUDING, EXCEPT
TO THE EXTENT PROHIBITED BY APPLICABLE LAW, THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT
SHALL INVENSYS CONTROLS BE LIABLE TO CONSUMER,
CONTRACTOR OR ANY THIRD PARTY FOR ANY
CONSEQUENTIAL, INCIDENTIAL, SPECIAL OR PUNITIVE
DAMAGES ARISING FROM OR RELATING TO USE OF THE
PRODUCT INCLUDING, BUT NOT LIMITED TO, LOSS OF
GOODWILL, LOSS OF PROFIT OR REVENUE, AND
PROPERTY DAMAGE, REGARDLESS WHETHER SUCH
LOSS OR DAMAGE IS BASED IN CONTRACT, WARRANTY,
TORT, NEGLIGENCE, STRICT LIABILITY, INDEMNITY,
PRODUCT LIABILITY, OR OTHERWISE AND EVEN IF
INVENSYS CONTROLS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.