FIGURE 15.
United States (inches)
Model
A
B
C
D
CRV-B-2
4
12
48
12
CRV-B-4
4
12
48
12
CRV-B-6
4
12
48
12
CRV-B-8
4
12
48
12
CRV-B-9
4
16
38
16
CRV-B-10 4
18
56
18
CRV-B-12 4
18
56
18
CRV-B-12A 4
18
56
18
Canada (inches)
Model
A
B
C
D
CRV-B-2
4
12
48
12
CRV-B-4
4
12
48
12
CRV-B-6
4
12
48
12
CRV-B-8
4
12
48
12
CRV-B-9
4
18
56
18
CRV-B-10 4
18
56
18
CRV-B-12 4
18
56
18
CRV-B-12A 4
18
56
18
Canada - (centimeters)
Model
A
B
C
D
CRV-B-2
10 30
122 30
CRV-B-4
10 30
122 30
CRV-B-6
10 30
122 30
CRV-B-8
10 30
122 30
CRV-B-9
10 46
142 46
CRV-B-10 10 46
142 46
CRV-B-12 10 46
142 46
CRV-B-12A 10 46
142 46
United States (inches)
Model
A
B
C
D
CRV-B-2
4
12
48
12
CRV-B-4
4
12
48
12
CRV-B-6
4
12
48
12
CRV-B-8
4
12
48
12
CRV-B-9
4
16
38
16
CRV-B-10 4
18
56
18
CRV-B-12 4
18
56
18
CRV-B-12A 4
18
56
18
Canada (inches)
Model
A
B
C
D
CRV-B-2
4
12
48
12
CRV-B-4
4
12
48
12
CRV-B-6
4
12
48
12
CRV-B-8
4
12
48
12
CRV-B-9
4
18
56
8
CRV-B-10 4
18
56
18
CRV-B-12 4
18
56
18
CRV-B-12A 4
18
56
18
Canada - (centimeters)
Model
A
B
C
D
CRV-B-2
10 30
122 30
CRV-B-4
10 30
122 30
CRV-B-6
10 30
122 30
CRV-B-8
10 30
122 30
CRV-B-9
10 46
142 46
CRV-B-10 10 46
142 46
CRV-B-12 10 46
142 46
CRV-B-12A 10 46
142 46
16
CORAYVAC
®
HEATING SYSTEMS
NOTE: 1. All dimensions are from the tube surface.
2. Clearances B, C and D can be reduced by 50% after 25’ (7 m) of tubing downstream
from where the burner and transition tube connect.
3. For Brooder Clearances, use United States clearances.
4. “-” indicates an unapproved application. Roberts-Gordon does not allow the installation of
unapproved applications.
1 FOOT DECO GRILLE
2 FOOT DECO GRILLE
BARRIER SHIELD
Clearances to Combustibles
FIGURE 13.
FIGURE 14.
A
B
C
D
A
B
C
D
A
B
C
D
United States (inches)
Model
A
B
C
D
CRV-B-2
4
12
12
12
CRV-B-4
4
12
12
12
CRV-B-6
4
12
12
12
CRV-B-8
4
12
12
12
CRV-B-9
— —
—
—
CRV-B-10 — —
—
—
CRV-B-12 — —
—
—
CRV-B-12A — —
—
—
Canada (inches)
Model
A
B
C
D
CRV-B-2
4
12
12
12
CRV-B-4
4
12
12
12
CRV-B-6
4
12
12
12
CRV-B-8
4
12
12
12
CRV-B-9
8
18
24
18
CRV-B-10 8
18
24
18
CRV-B-12 8
18
24
18
CRV-B-12A 8
18
24
18
Canada - (centimeters)
Model
A
B
C
D
CRV-B-2
10 30
30
30
CRV-B-4
10 30
30
30
CRV-B-6
10 30
30
30
CRV-B-8
10 30
30
30
CRV-B-9
20 46
61
46
CRV-B-10 20 46
61
46
CRV-B-12 20 46
61
46
CRV-B-12A 20 46
61
46