WARNING

Installation must be done by an electrician qualified 
in the installation and service of control systems 
for heatin

g

 equipment.

Improper installation, adjustment, alteration, service 
or maintenance can result in death, injury or 
property dama

g

e. Read the Installation, Operation 

and Service Manual thorou

g

hly before installin

g

 or 

servicin

g

 this equipment.

Installer

Please take the time to read and 

u

nderstand

these instr

u

ctions prior to any installation.

Installer m

u

st gi

v

e a copy of this man

u

al to the owner.

Owner

Keep this man

u

al in a safe place in order to pro

v

ide

yo

u

r ser

v

ice technician with necessary information.

© 2014 Roberts-Gordon Europe Limited

P/N 160101UK Orig 07/14

Combat

®

 HVE

Energy Saving Fans

with Control Options

Installation, Operation &

                        Service Manual

Summary of Contents for Combat HVE 400

Page 1: ...heating equipment Improper installation adjustment alteration service or maintenance can result in death injury or property damage Read the Installation Operation and Service Manual thoroughly before installing or servicing this equipment Installer Please take the time to read and understand these instructions prior to any installation Installer must give a copy of this manual to the owner Owner K...

Page 2: ......

Page 3: ...tion 2 1 1 Electrical Requirements 2 1 2 Check Installation Materials 2 1 3 Safety Labels and Their Placement 3 SECTION 2 Specifications 4 2 1 Electrical Specifications 4 2 2 Fan Specifications 4 2 3 Dimension Data 4 SECTION 3 Critical Considerations 5 3 1 Location and Suspension 5 3 2 Minimum Required Installation Clearances 5 SECTION 4 Installation 6 4 1 Preparation 6 4 2 Electrical Supply 7 SEC...

Page 4: ......

Page 5: ... 3 Mounting Hole Layout 6 Figure 4 Suspension Methods 7 Figure 5 BJ8 Fan Control Wiring Diagram 8 Figure 6 DP5 Fan Control Wiring Diagram 8 Figure 7 WAC6 Fan Control Wiring Diagram 9 Figure 8 HVE Fan Without Speed Control Wiring Diagram 9 Figure 9 Internal Components Diagram 12 ...

Page 6: ......

Page 7: ...intained in accordance with these instructions These instructions refer to appliances designed to operate in the European Union Appliances designed for other countries Non European Union are available on request This appliance must be installed in accordance with the local and national codes in force and used only in a sufficiently ventilated space as specified in these instructions Before install...

Page 8: ...er clearances to combustibles see heater Installation Operation and Service Manual for further details If you require additional manuals con tact Roberts Gordon at 44 0 121 506 7700 or at www robertsgordon co uk 1 1 Electrical Requirements Failure to comply with the installation instructions will invalidate the limited warranty All wiring must comply with current wiring regulations and any local r...

Page 9: ...ement Product safety signs or labels should be replaced by product user when they are no longer legible Please contact Roberts Gordon Europe Limited or your ROBERTS GORDON independent distributor to obtain replacement signs or labels FIGURE 1 Label Placement Description Part Number Logo Label 91040030 Shock Hazard Label 91008001 Address Label 91040006 Wiring Diagram Label 91040400 Terminal Connect...

Page 10: ...F 3 8 12 Electrical Supply 230 V 50 Hz 1 Ø Starting Current A 1 5 6 4 6 0 Running Current A 1 0 1 6 2 6 Noise Level 3m NR dB A 55 68 70 Maximum Ambient Temperature C 60 65 40 Thermostat Recommended Minimum Setting C 15 15 15 Maximum Setting C 30 30 30 Recommended Minimum Setting above room temperature C 3 3 3 Model HVE 400 HVE 450 HVE 650 A Depth mm 300 305 284 B Casing Width mm 527 610 790 C Over...

Page 11: ... minimum of 10 mm diameter mild steel Four suspension points M10 nuts are located on top of fan Mounting hardware must be sufficient to support fan weight as listed in the dimension data on Page 4 Sec tion 2 3 Must be installed in a manner which allows access to all serviceable components 3 2 Minimum Required Installation Clearances Clearances around fan must be as indicated on Page 4 Section 2 3 ...

Page 12: ...above See Page 7 Figure 4 Drop rods must be a minimum of 10 mm diameter mild steel Four suspension points M10 nuts are located on top of fan Mounting hardware must be sufficient to support fan weight as listed in the dimension data on Page 4 Sec tion 2 3 Must be installed in a manner which allows access to all serviceable components 4 1 2 Suspension Mounting Model HVE 400 HVE 450 HVE 650 A mm 493 ...

Page 13: ...z single phase supply connected to terminals L N and Earth Polarity L N must be correct The voltage between neutral and earth should be 0 and never exceed 15 volts All fans and controls must be correctly earthed All external wiring must comply with relevant IEE and local regulations and be carried out by a qualified electrician ...

Page 14: ...aced it must be replaced with wiring material having a temperature rating of at least 105 C and 600 V FIGURE 5 BJ8 Fan Control Wiring Diagram FIGURE 6 DP5 Fan Control Wiring Diagram DANGER Electrical Shock Hazard Disconnect electric before service More than one disconnect switch may be required to disconnect electric to the unit Failure to follow these instructions can result in death or electrica...

Page 15: ...SECTION 5 TYPICAL EXTERNAL WIRING DIAGRAMS 9 of 12 FIGURE 7 WAC6 Fan Control Wiring Diagram FIGURE 8 HVE Fan Without Speed Control Wiring Diagram ...

Page 16: ...n trol over HVE Fan speed See Page 8 Section 5 wir ing diagrams to utilize HVE Fan thermostat In this case each fan will turn on when temperature at fan exceeds thermostat setpoint The fans speed will be determined by speed set on controller To disable HVE Fan thermostat wire line power to terminal 1 rather than terminal L In this configuration fan con trol ON OFF switch will be used to turn HVE F...

Page 17: ... manual Failure to follow these instructions can result in death electric shock injury or property damage Explosion Hazard DANGER Electrical Shock Hazard Fire Hazard DANGER Electrical Shock Hazard Disconnect electric before service More than one disconnect switch may be required to disconnect electric to the unit Failure to follow these instructions can result in death or electrical shock ...

Page 18: ...ON OPERATION AND SERVICE MANUAL 12 of 12 FIGURE 9 Internal Components Diagram Model Description Part Number HVE 400 Axial Fan 400 mm A263A HVE 450 Axial Fan 450 mm A268A HVE 650 Axial Fan 650 mm A269 N A Thermostat 230 V C2334B ...

Page 19: ......

Page 20: ......

Reviews: