EN -21-
4.9.5
Feedback information
•
DMX and system LED feedback (7):
Green= DMX512 frame detected
Red = Problem on DMX512 frame and/or system default – details available in 4/6
Fixture Tools menu
•
If DMX512 data lost, the following message is displayed :
“Push select to reset DMX values”
The last received DMX values are stored but it is possible to inactivate the current values by
pressing the Select key (as well as the Master function) in order to get a total control of the
fixture locally. When a DMX signal is detected, the DMX control is active again.
•
¥
¥
¥
¥
signal indicates a wireless DMX
Signal
Information
Switched off – no symbol
The fixture is not paired with a transmitter
Slow intermittent display
The fixture is paired with a transmitter but the DMX signal is not
detected
Continuous display
The fixture is paired with a transmitter and the DMX signal is
detected
Rapid intermittent display
Lost connection with the transmitter or in connection with the
transmitter
5 Service
5.1
Preventive maintenance
5.1.1
Frequency
General maintenance should be performed at least once a year or more frequently if the equipment is
operated in adverse conditions (smoke, heat, humidity, touring, etc.).
5.1.2
General cleaning
Remove dust from the unit (air vents, printed circuit boards, etc.).
During cleaning:
•
LED must be protected to avoid dust on it.
•
Fan blades must be locked.
See 5.1.4 LED access for cleaning access to LED and fan
5.1.3
General visual check
•
No trace of heat.
•
No loose contacts.
•
No missing parts.
•
Tighten mechanical assemblies (screws, bolts and nuts, ground connections, etc.).
EN
Summary of Contents for ZEP 660 SX
Page 11: ...EN 9 3 3 4 Shutters Step 1 Step 2 Step 3 EN...
Page 17: ...EN 15 4 7 Beam rotation 4 7 1 Range Function Range Gobo shutters 4 7 2 Control EN...
Page 35: ...FR 9 3 3 4 Couteaux Etape 1 Etape 2 Etape 3 FR...
Page 41: ...FR 15 4 7 Rotation de l image 4 7 1 Etendue Fonction Etendue Gobo Couteaux 4 7 2 Contr le FR...