background image

EN

 

EN -1- 

 

User’s instructions 

GENERAL INSTRUCTIONS 

1. 

Not for residential use. 

2. 

These fixtures must only be serviced by a qualified technician.

 

3. 

In addition to the instructions indicated on this page, relevant health and safety requirements of the appropriate EU 

Directives must be adhered to at all times. 

4. 

This fixture is in compliance with section 17 - Lighting appliance for theatre stages, television, cinema and photograph 

studios. Standards NF EN 60598-1 and NF EN 60598-2-17. 

5. 

This fixture is rated as IP20, and is for indoor use only. 

FIXTURE 

6. 

Ensure fixture is correctly mounted on an appropriate support. 

7. 

Protection screens and lenses must be replaced in the event of any damage, such as cracks or deep scratches, since 

these might reduce performance. 

8. 

When hung or flown the fixture must be secured by an additional hanging accessory (such as a safety cable or bond) of 

suitable length. Safety bonds or cables must be securely attached to the back of the fixture and be as short as possible, or 

rolled up as necessary, to minimise travel distance should the fixture be dislodged. 

9. 

Movable accessories (scroller, etc.) must also be secured with a suitable safety cable or bond at the front of the fixture

The combined weight of both the fixture and the accessories must be considered when choosing the load-bearing 

capability of safety cable or bond. 

10.  Do not open lighting fixture when the source is on. 

11.  WARNING: LED source become hot during use. Allow fixture to cool before servicing. 

12.  Do not tamper with design of fixture nor any of its safety features. 

13.  Tighten electrical mains cable connections regularly and replace with one of identical specification if damaged. 

14.  Use only with correct power supply. 

VENTILATION 

15.  Keep well away from flammable material. 

16.  Not for outdoor use. Do not cover. Do not permit fixture to get wet. 

17.  To avoid overheating, do not obstruct air vents. 

18.  Ensure any cooling fans are in correct working order. If fans are not working, turn fixture off immediately and service as 

necessary. 

CLEANING 

19.  Do not touch LED source with fingers. 

20.  Clean all optical parts with alcohol-based cleaner. 

21.  Clean all filters regularly. 

POWER SUPPLY 

22.  Disconnect from the mains before servicing. 

23.  Mains connection only. Do not connect to "electronic output" such as dimmer. 

24.  Not for outdoor use. Do not cover. 

25.  Ensure power supply circuit breakers, always remain accessible. 

PLEASE NOTE  

These products have been built to conform to European standards relating to professional lighting equipment. Any modification 

made to our products will void the manufacturers' warranty. 

 

 

Summary of Contents for TIBO

Page 1: ...obert Juliat U S A 48 Capital Drive Wallingford CT 06492 USA phone 203 294 0481 fax 203 294 0482 info robertjuliatamerica com TIBO Projecteur de THEATRE SINGLE LENS LUMINAIRE Standard Standard Nord Am...

Page 2: ...lement tre assur s par une lingue de taille appropri e ancr e l avant de l appareil Tenir compte de leur poids pour la charge d accrochage 10 Ne pas ouvrir l appareil sous tension 11 Source LED et sup...

Page 3: ...MX x Origine de la commande a analogique l valeur locale d DMX protection thermique m potentiom tre local M master Select 1 4 H i B y t e C H A N N E L C h 1 V a l 0 Canal 1 gradation 8 bits Informati...

Page 4: ...en 8 bits 1 canal DMX 16 Gradation en 16 bits 2 canaux DMX 2 8 L I G H T C U R V E l i n e a r S lection de la courbe de gradation Select 2 8 L I G H T C U R V E l i n e a r R glage linear Courbe lin...

Page 5: ...ventilateur x10V 11V Vd 13V VC Tension p riph rique x10V 4 5V Vc 5 5V 4 8 L E D S U P P L Y a a a V l e d A Tension aux bornes du module LED Information aaa Etat du module LED OK NOK A Tension aux bo...

Page 6: ...ge Fonction Gradation 1 0 255 0 100 Gradation de l intensit lumineuse Stroboscope 2 0 0 Intensit 0 stroboscope inactif 1 254 1 99 Stroboscope lent rapide 255 100 Intensit 100 stroboscope inactif R sol...

Page 7: ...nsmetteur et le signal DMX est d tect Affichage discontinu rapide Perte de la liaison avec le transmetteur ou en liaison avec le transmetteur 2 Maintenance 2 1 Maintenance pr ventive 2 1 1 Fr quence U...

Page 8: ...fixture The combined weight of both the fixture and the accessories must be considered when choosing the load bearing capability of safety cable or bond 10 Do not open lighting fixture when the sourc...

Page 9: ...st command detected http mode a analog l local level d DMX thermal protection m local potentiometer M master Select 1 4 H i B y t e C H A N N E L C h 1 V a l 0 Channel 1 8 bits dimmer coarse Data Ch D...

Page 10: ...b i t s Parameters 8 8 bits dimming 1 DMX channel 16 16 bits dimming 2 DMX channels 2 8 L I G H T C U R V E l i n e a r Choice of dimming curve Select 2 8 L I G H T C U R V E l i n e a r Parameters l...

Page 11: ...F I X T C O U N T E R 0 0 0 0 0 0 0 0 H PSU hour counter 3 8 P O W E R S U P P L Y a a a V I 5 8 4 V D 1 1 8 V C 4 9 Fixture PSU Data aaa PSU feedback OK NOK VI PSU voltage x10V 54V Vi 61V VD Fan volt...

Page 12: ...if data errors are detected Wireless DMX feedback see 4 7 3 Feedback information 2 2 3 DMX remote control 8 bits mode Channel Value Percent Function Dimmer 1 0 255 0 100 Course dimming Resolution 8 bi...

Page 13: ...al Information Switched off no symbol The fixture is not paired with a transmitter Slow intermittent display The fixture is paired with a transmitter but the DMX signal is not detected Continuous disp...

Reviews: