background image

EN

EN - 4 -

5  Operation

6  DMX Chart

   Switch on the profile by connecting power cable.

   The light beam zoom and focus can be set by 

 

using the control knobs A & B.

   Beam adjustments can also be made by using 

 

the shutters C and the fixture rotation (by unlocking

 

the button D)

3

Robert Juliat reserves the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.

DMX address

Mode 1: 

Dimmer8B 

Mode 2: 

Dimmer16B

Mode 3: 

Profile8B

Mode 4: 

Profile16B

Dimmer 

Dimmer 

Dimmer 

Dimmer 

Dimmer fine 

Strobe duration 

Dimmer fine 

3

Strobe speed

Strobe duration 

4

Response time

Strobe speed 

5

Control mode

Response time 

6

Control mode

Strobe duration

Range min

Range max

Function

0

0

Strobe OFF 

1

255

Strobe ON - 1 ms 

T

 20 ms

Response time

Range min

Range max

Function

0

0

OFF

1

255

Dimmer timing: 0,1 s 

T

 4 s 

Strobe speed

Range min

Range max

Function

0

255

Frequency: 0,1 Hz 

T

 10 Hz 

(*) Function activated after 5 seconds 

     - needs to go back to zero to activate second function.

Default IP address:

Available on ID plate

D

2

1

C

Control mode*

Range min

Range max

Function

By default

If activated in web interface/RDM

-

-

10 

-

RDM Disable

11 

20 

-

RDM Enable

A

B

A

A

B

B

FOCUS

ZOOM

FOCUS

ZOOM

Summary of Contents for TIBO HE

Page 1: ...e 33 0 3 44 26 51 89 fax 33 0 3 44 26 90 79 info robertjuliat fr www robertjuliat com User s manual Included For more information and updates www robertjuliat com V1 CAL03 OR CAL04 D4 x4 PF100M DN4120...

Page 2: ...on 13 WARNING LED source become hot during use Allow fixture to cool before servicing 14 Do not tamper with design of fixture nor any of its safety features 15 Tighten electrical mains cable connecti...

Page 3: ...5 pin Protocol USITT DMX 512 A RDM 5 Ethernet Connector RJ45 Protocol Art Net sACN web interface 6 2 4 3 5 18 7 1 12 16 15 9 8 14 11 10 13 17 2 1 3 4 5 EN 3 3 Functions Description 1 Identification p...

Page 4: ...mmer Dimmer Dimmer Dimmer 2 Dimmer fine Strobe duration Dimmer fine 3 Strobe speed Strobe duration 4 Response time Strobe speed 5 Control mode Response time 6 Control mode Strobe duration Range min Ra...

Page 5: ...rapide Robert Juliat S A S 32 rue de Beaumont F 60530 Fresnoy en Thelle t l 33 0 3 44 26 51 89 fax 33 0 3 44 26 90 79 info robertjuliat fr www robertjuliat fr Manuel utilisateur Pour plus d informati...

Page 6: ...oit froid avant toute intervention 14 Ne modifiez pas la conception de l appareil ni aucun de ses dispositifs de s curit 15 Resserrer r guli rement les connexions et contr ler l tat des c bles Si le c...

Page 7: ...iris 18 Point de fixation du c ble de s curit pour les accessoires 4 lectrique 1 Puissance d entr e Connecteur Neutrik powerCON TRUE1 TOP Max 16A Puissance d entr e 100 264V 50 60Hz Doit tre raccord...

Page 8: ...ms Temps de r ponse Gamme min Gamme max Fonction 0 0 Eteint 1 255 Temps gradation 0 1 s T 4 s Vitesse stroboscope Gamme min Gamme max Fonction 0 255 Fr quence 0 1 Hz T 10 Hz Fonction activ e apr s 5...

Reviews: