EN
EN - 4 -
5 Operation
6 DMX Chart
1
Switch on the profile by connecting power cable.
2
The light beam zoom and focus can be set by
using the control knobs A & B.
3
Beam adjustments can also be made by using
the shutters C and the fixture rotation (by unlocking
the button D)
3
Robert Juliat reserves the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.
DMX address
Mode 1:
Dimmer8B
Mode 2:
Dimmer16B
Mode 3:
Profile8B
Mode 4:
Profile16B
1
Dimmer
Dimmer
Dimmer
Dimmer
2
Dimmer fine
Strobe duration
Dimmer fine
3
Strobe speed
Strobe duration
4
Response time
Strobe speed
5
Control mode
Response time
6
Control mode
Strobe duration
Range min
Range max
Function
0
0
Strobe OFF
1
255
Strobe ON - 1 ms
T
20 ms
Response time
Range min
Range max
Function
0
0
OFF
1
255
Dimmer timing: 0,1 s
T
4 s
Strobe speed
Range min
Range max
Function
0
255
Frequency: 0,1 Hz
T
10 Hz
(*) Function activated after 5 seconds
- needs to go back to zero to activate second function.
Default IP address:
Available on ID plate
D
2
1
C
Control mode*
Range min
Range max
Function
By default
If activated in web interface/RDM
0
0
-
-
1
10
-
RDM Disable
11
20
-
RDM Enable
A
B
A
A
B
B
FOCUS
ZOOM
FOCUS