background image

- 16 - 

7  Technical specifications 

 
 
 
Dimensions and weight*: 
 
 

Ref. 

Ø 

Weight* 

JAL2 - 206 

206 

298 

415 

263 

3Kg 

JAL2 - 280 

280 

372 

487 

338 

4,3Kg 

JAL2 - 340 

340 

432 

545 

416 

5,5Kg 

JAL2 - 404 

404 

493 

612 

494 

6,9Kg 

(*) Without adaptation 

 
 
 
 
 
 
 
 
 

Summary of Contents for JAL2-206

Page 1: ...bertjuliat fr Robert Juliat U S A 48 Capital Drive Wallingford CT 06492 USA phone 203 294 0481 fax 203 294 0482 info robertjuliatamerica com JALOUSIE 2 Specialist products JAL2 206 V4 JAL2 280 V6 JAL2...

Page 2: ...9 4 2 Control board 10 4 2 1 Controls 10 4 2 2 Display 10 4 2 3 Menus and parameters 11 4 2 4 LED feedback 13 4 2 5 RESET 13 4 3 DMX remote control 13 5 Servicing 14 5 1 Preventative maintenance 14 5...

Page 3: ...ise travel distance should the unit be dislodged 10 Movable accessories barn doors spill rings etc must also be secured with a suitable safety cable or bond at the front of the unit 11 The combined we...

Page 4: ...dle 6 Optional local potentiometer 7 Identification plate 8 Setup display 9 LED feedback 10 Setup buttons Reference Description 1 COU0003265 IEC C13 power connector Reference Description Local potenti...

Page 5: ...of an adaptation kit to use the JALOUSIE2 on Fresnel lanterns is necessary The JALOUSIE2 can be delivered with the mounting plate fitted on the JALOUSIE2 Contact your distributor for compatibility on...

Page 6: ...tter results JALOUSIE2 blades have to be perpendicular to the arc of the lamp 3 1 3 Safety cable JALOUSIE2 must be secured with appropriate safety cable not provided from attachment point A to lantern...

Page 7: ...holder for barndoors gel frame scroller JALOUSIE2 comes with a front accessory holder having the same specifications as the one on the luminaire except for JAL2 340 adaptation kit for Robert Juliat 3...

Page 8: ...t power Connectors Recommended cable not provided 90 250 V 50 60 Hz 40 W IEC C13 C14 H05 RRF 3G 0 75 3 2 3 DATA Remote control uses USITT DMX 512 A protocol Input and output connections are using XLR...

Page 9: ...put Control of the aperture can be done locally through the display and optional potentiometer or remotely by using USITT DMX 512 protocol Choice of LTP or HTP merger is possible in setup menu Dimming...

Page 10: ...e blinking data value 5 exit Exit the current menu option and or go back 6 reset Hard CPU reset 7 Data DMX LED feedback Cf 4 3 1 6 C H A N N E L h 1 P O S I T I O N d 0 Function Values 1 Merger mode h...

Page 11: ...1 L O C A L V A L U E 0 C H A N N E L 1 L O C A L V A L U E 0 Value Function 0 100 Local value 3 6 C H A N N E L h 1 A N A L O G V A L U E O F F 4 6 C H A N N E L h 1 M O T O R R E S E T C O N F I R...

Page 12: ...P R E F E R E N C E S M O D E H T P 5 8 P R E F E R E N C E S M O D E H T P Value Function HTP Highest Takes Precedence LTP Lastest Takes Precedence 6 8 P R E F E R E N C E S C U R V E L M 1 6 b i t...

Page 13: ...0 BRAKE off very fast movement 5 flash s 1 255 BRAKE on fast movement 2 flash s smooth movement 0 01 flash s if Brake function activated in PREFERENCES menu If BRAKE function is not activated blades m...

Page 14: ...the minimum position 0 and the maximum position 100 Positions need to be adjusted if light spills at 0 are detected or if blades have been changed DMX must be disconnected Local value must be used to...

Page 15: ...close the blades by DMX completely Local value or potentiometer 0 and HTP merger mode activated Change local values to 0 and or change merger mode to LTP in menu 5 6 Impossible to close the blades by...

Page 16: ...Technical specifications Dimensions and weight Ref A B C Weight JAL2 206 206 298 415 263 3Kg JAL2 280 280 372 487 338 4 3Kg JAL2 340 340 432 545 416 5 5Kg JAL2 404 404 493 612 494 6 9Kg Without adapt...