background image

11

4. Control menu map

Default settings=Bold print

Level 1

Level 2

Level 3

Level 4

Level 5

Level 6

Level 7

DMXA

Set DMXA

001-255

DMX Pres

Mode 1

Mode 2

Info

POn Time

Total

       

Reset

DMX In

Pan

0-255

:

Dimm F

0-255

Hea Temp

Current

Highest
High Res

Sw Ver

IC-1
IC-2
IC-3

Pers

DMX Pres

Mode 1

Mode 2

Pan Rev

On, 

Off

Tilt Rev

On,

 Off

P/T Mode

Speed

Time

P/T Feed

On

, Off

Display

Turn
On/Off T

On, 

Off

Contrast

0-100%

Backlight

0-100%

BLC DMC

On, 

Off

BLC P/T

On, 

Off

Mic Sens

0...

10

...19

Fans

Auto

, High,Quiet

C Mix M

RGBW

, CMY

White P

On

, Off

Dimmer C

Square

, Linear

Temp Uni

°C

, °F

I Ef Pos

Pan

:

Dim F

Store

Defaults

Manual

Pan

0-255

:

Dimm F

0-255

Test Prg

Static

Pan

0-255

Tilt

0-255

Run

Dynamic

Summary of Contents for Robin LedBeam 150

Page 1: ...1 Version 1 0 Version 1 2 ...

Page 2: ...trol menu map 11 5 Control menu 13 5 1 Addressing DMXA 13 5 2 Fixture information Info 13 5 3 Personality Pers 14 5 4 Manual Control Manual 15 5 5 Test program Test Prg 15 5 6 Stand alone St Alone 15 5 7 Reset 16 5 8 Special functions Special 16 6 RDM 18 7 Error and information messages 18 8 Technical Specifications 19 9 Maintenance and cleaning 21 9 1 Replacing fuse 22 10 Photometric diagrams 23 ...

Page 3: ... power company Always disconnect the fixture from AC power before cleaning removing or installing any part of the fixture The power plug has to be accessible after installing the fixture Do not overload wall outlets and extension cords as this can result in fire or electric shock Do not allow anything to rest on the power cord Do not locate this fixture where the cord may be damaged by persons wal...

Page 4: ... blocked when rigging derigging or servicing the fixture The fixture becomes hot during operation Allow the fixture to cool approximately 15 minutes prior to manipu late with it To avoid damage of an internal optical system of the fixture never let the sunlight or other light source lights directly to the lens array even when the fixture is not working Operate the fixture only after having familia...

Page 5: ...view 1 Lens array 2 Yoke 3 Mains IN 4 Attachment point for a safety wire 5 Mains OUT 6 Control panel 7 DMX IN 8 DMX OUT 9 Base 10 Slots for mounting bracket omega CL 1 Moving head 2 Attachment point for safety cable 3 Base ...

Page 6: ... Green Earth The device falls under class one and must be earthed grounded Design of the ROBIN LEDBeam 150 allows to connect several fixtures toAC mains power in one interconnected daisy chain using power input and throughput connectors Needed daisy chain cords are stated in the chapter Technical specifications The max number of connected fixtures depends on the AC mains power voltage CE ETL 15 fi...

Page 7: ...d periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury or damage to property The fixture has to be installed out of the reach of people If the fixture shall be lowered from the ceiling or high joists profes...

Page 8: ...void illuminating one fixture with another 3 3 Eggcrate installation Disconnect the fixture from mains before installing the eggcrate Screw the eggcrate 1 on the lens array module via the three screws 2 1 Omega bracket 2 Clamp 3 Truss 4 Attachment point 5 Safety chain ...

Page 9: ...onnect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Up to 32 fixtures can be interconnected Caution At the last fixture the DMX cable has to be terminate...

Page 10: ... connected with the fixture NOTE when you disconnect the DMX wireless module from fixture press and hold lock 5 during getting the wireless module out To link the fixture with DMX transmitter The fixture can be only linked with the transmitter by running the link procedure at DMX transmitter After linking the level of DMX signal 0 100 is displayed in the menu item Stat Special Vireless Stat To unl...

Page 11: ...High Res Sw Ver IC 1 IC 2 IC 3 Pers DMX Pres Mode 1 Mode 2 Pan Rev On Off Tilt Rev On Off P T Mode Speed Time P T Feed On Off Display Turn On Off T On Off Contrast 0 100 Backlight 0 100 BLC DMC On Off BLC P T On Off Mic Sens 0 10 19 Fans Auto High Quiet C Mix M RGBW CMY White P On Off Dimmer C Square Linear Temp Uni C F I Ef Pos Pan Dim F Store Defaults Manual Pan 0 255 Dimm F 0 255 Test Prg Stati...

Page 12: ...g 1 Prog 2 Prog 3 Pr Edit Prog 1 Step 1 Pan Prog 2 Prog 3 Step 40 F Tim 0 25 5 S Tim 0 25 5 COPY Prg End 1 40 Reset Special RDM Low RDM Hight Wireless Stat Unlink Adjust DMX Val Pan 0 255 Dimm F 0 255 Clalib Cal Mech Pan C 0 255 Tilt C 0 255 Zoom C 0 255 Store Cal Col Red C 0 255 Gre C 0 255 Blu C 0 255 Whi C 0 255 Store Cal Load Sw Upd On Off ...

Page 13: ... to flash 0001 with actually stored DMX address DMX Pres DMX preset Use the menu to select desired channel mode Mode 1 22 control channels default Mode 2 16 control channels 5 2 Fixture information Info POn Time Power on time Select this menu to read the number of fixture operation hours Total The item shows the total number of the operation hours since the ROBIN LEDBeam 150 has been fabricated Re...

Page 14: ...ontrol panel Contrast Use this function to adjust contrast of the display 0 100 Backlight Use this function to adjust backlight of the display 0 100 BLC DMC Blackout during movement correction Set this option on if you wish to close light output during the time when the head goes to its correct position which has been changed by an external force BLC P T Active blackout The menu item allows to clo...

Page 15: ...1 The option runs user created program 1 Prog 2 The option runs user created program 2 Prog 3 The option runs user created program 3 Select the program you wish and press ENTER The selected program starts running By Pressing ENTER again program pauses running Pr Edit Editing program Select this menu to edit or create the program The ROBIN LEDBeam 150 has one built in program and one user editable ...

Page 16: ...zoom position Cal Col Use this menu to set white colour 5600K Calibration of the pan tilt zoom via the control board 1 Disconnect DMX controller from the fixture and enter the Cal Mech menu 2 Use the PREV and NEXT to find Pan C and press ENTER 3 Set desired value and save it by pressing ENTER 4 Repeat steps 2 and 3 for Tilt C and Zoom C 5 After calibrating both effects find item Store and press EN...

Page 17: ...e if you using the flash cable RS232 DMX with the USB input of the Robe Universal Interface if you using the USB cable Connect DMX output of the Robe Universal Interface with the fixture via a standard DMX cabel Turn both the computer and the fixture on Make sure the lamp is switched off only if the fixture has a lamp 2 Switch the fixture to the updating mode Special SW Upd On Note If you do not w...

Page 18: ...Beam 150 is the following Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_VERSION_LABEL DMX_START_ADDRESS IDENTIFY_DEVICE DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SENSOR_DEFINITION SENSOR_VALUE DISPLAY_INVERT DISPLAY_LEVEL PAN_INVERT TILT_INVERT DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DE...

Page 19: ...strobe pulse effect with variable speed Opening closing pulse effect with variable speed Dimmer Smooth dimmer from 0 100 Pan Tilt Max pan movement range 540 Max tilt movement range 228 16 bit movement resolution Automatic Pan Tilt position correction Remotely controllable speed of pan tilt movement for easy programming Movement control tracking and vector Control 2 row LCD display 4 buttons Readou...

Page 20: ...r Neutrik PowerCon A type NAC3MPA AC power output Chassis connector Neutrik PowerCon B type NAC3MPB Rigging Mounting points pair of 1 4 turn locks Mounting horizontally or vertically via Omega bracket Temperatures Maximum ambient temperature 45 C Maximum housing temperature 80 C Distances Min distance from flammable surfaces 0 4 m Min distance of illuminated objects 0 8 m Total heat dissipation 75...

Page 21: ... circumstances should solvents be used Never use solvents for cleaning lenses in the moving head It is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light output but will also allow the fixt...

Page 22: ...Unscrew four screws 4 on the top chassis 5 Lay down the fixture and unscrew four screws 6 on the bottom plate 9 to push out inside module of the base 4 Unscrew two screws 8 on the bottom plate to remove rear panel of the fixture 7 5 Now you have access for the fuse holder 10 in the inside module of the base 6 Remove the old fuse from the fuseholder 7 Install the new fuse into the fuseholder 8 Asse...

Page 23: ...23 10 Photometric diagrams ...

Page 24: ...24 ...

Page 25: ...25 ...

Page 26: ...ng s r o Palackého 416 757 01 Valašské Meziříčí Czech Republic 11 ChangeLog This section summarizes all types of changes in the user manual Version of the manual Date of issue Description of changes 1 1 05 05 2017 EggCrate installation added DMX protocol ver 1 1 1 2 07 06 2017 Quiet mode for fan in menu Personality DMX protocol ver 1 2 ...

Page 27: ... OFF step 30 34 RGBW colour mixing mode step 35 39 CMY colour mixing mode step 40 44 Pan Tilt speed mode step 45 49 Pan Tilt time mode step 50 54 Blackout while pan tilt moving step 55 59 Disabled blackout while pan tilt moving step 60 64 Dimmer curve square law step 65 69 Dimmer curve linear step 70 74 Fans mode Auto step 75 79 Fans mode High step 80 84 White point 8000K ON step 85 89 White point...

Page 28: ...er 140 Summer Blue step 31 32 Filter 124 Dark Green step 33 34 Filter 106 Primary Red step 35 36 Filter 111 Dark Pink step 37 38 Filter 115 Peacock Blue step 39 40 Filter 126 Mauve step 41 42 Filter 117 Steel Blue step 43 44 Filter 118 Light Blue step 45 46 Filter 122 Fern Green step 47 48 Filter 182 Light Red step 49 50 Filter 121 Filter Green step 51 52 Filter 128 Bright Pink step 53 54 Filter 1...

Page 29: ... 778 Millennium Gold step 131 132 Filter 793 Vanity Fair step 133 235 Raw DMX proportional 236 245 Rainbow effect with fade time from slow fast proportional 246 255 Rainbow effect without fade time from slow fast proportional 8 8 Red Cyan 8 bit 0 255 Colour saturation control coarse 0 100 255 default proportional 9 Red Cyan 16bit 0 255 Colour saturation control fine 255 default proportional 10 9 G...

Page 30: ...rted Subtraction mode Virtual Colour mix step 70 128 Reserved 129 Virtual colors virtual has priority step 130 254 Crossfade crossfade between Virtual and Colour mix proportional 255 Colour channels Colour mix has priority step 18 14 Zoom 0 255 Zoom from max to min beam angle 128 default proportional 19 Zoom fine 0 255 Fine zooming 0 default proportional 20 15 Shutter strobe 0 31 Shutter closed st...

Page 31: ...ight Blue 0 255 76 30 Filter 122 Fern Green 98 255 0 4 Filter 182 Light Red 255 16 2 0 Filter 121 Filter Green 165 255 0 0 Filter 128 Bright Pink 255 0 13 32 Filter 131 Marine Blue 73 245 27 30 Filter 132 Medium Blue 0 230 120 0 Filter 134 Golden Amber 166 83 0 0 Filter 135 Deep Golden Amber 255 50 0 0 Filter 136 Pale Lavender 140 101 25 40 Filter 137 Special Lavender 110 60 45 102 Filter 138 Pale...

Page 32: ...Blue 245 213 14 147 Filter 204 Full C T Orange 230 131 3 3 Filter 219 Fluorescent Green 99 148 16 50 Filter 206 Quarter C T Orange 199 152 0 60 Filter 247 Filter Minus Green 255 79 0 187 Filter 248 Half Minus Green 255 138 0 112 Filter 281 Three Quarter C T Blue 225 255 99 189 Filter 285 Three Quarter C T Orange 181 121 0 15 Filter 352 Glacier Blue 0 161 49 90 Filter 353 Lighter Blue 0 115 21 97 F...

Reviews: