Robe Haze 400 FT User Manual Download Page 5

5

4. Setup

Remove all packing materials from shipping box. Check that all foam and plastic padding is removed.

Place machine on a fl at surface and remove hazer liquid tank cap.

Note the maximum liquid level mark located on the rear of the hazer.

Pour hazer liquid into the liquid tank, being careful not to exceed the maximum liquid level. DO NOT OVER-

FILL. Use only ROBE hazer liquid or other dealer-recommended high-quality hazer liquid. Any other types of 

liquid can damage the unit. When liquid level reaches the fi ll line, place cap back on liquid tank.

Your hazer may be operated with or without a remote controller. If you will be controlling your unit remotely, 

fi rmly attach the remote control cable to the proper input.

5. Operation

Plug power cord into a grounded electrical outlet.

To operate without remote control, simply turn hazer on. Haze emission will begin automatically.

To operate via remote control, press the appropriate button on the remote to begin haze emission.  

For further information on operating your Haze 400 FT, see the section titled, ”Remote Control Operation”.

If your model includes a mounting bracket designed for overhead installation, it may be installed at fl oor level 

or suspended overhead. If the unit is to be mounted using the bracket, avoid suspending the unit such that 

haze is emitted directly toward any one’s face. Whatever installation method you choose, do not allow the unit 

to have more than a 15 degree angle of inclination.

Important.

Always monitor tank liquid level during operation.

Running a hazer with no liquid can permanently damage the unit! 

If you experience low output, mechanical noise or no output at all, unplug immediately. Check liquid level, the 

external fuse, remote connection, and power from the wall. If all of the above appears to be O.K., plug the unit 

in again. If hazer does not function after 30 seconds, discontinue operation or permanent damage to the unit 

may result. Return the machine to your ROBE distributor. Always drain tank before mailing or transporting 

this unit.

6. Remote Control Operation

Haze 400 FT uses 10 meter wired multi-function remote controller with 1⁄4” stereo plug . Press the red POWER 

button to activate  the remote control. Press the yellow TIMERS button to activate the timer function. Adjust the 

interval between each haze emission (within the range of 10 seconds to 5 minutes) by means of the INTER-

VAL control knob. Adjust the duration of each haze emission (within the range of 1 to 90 seconds) by means 

of the DURATION control knob. When pressed, the green MANUAL button activates the hazer, overriding all 

other function controls.

7. DMX Operation 

The Haze 400 FT has onboard DMX control. Currently, it uses 1 channel to control output operation. The DMX 

channel is set on the back panel of the Haze 400 FT by setting the dip switches to the desired channel:

If Channel  has a value from 0 to 5, the unit is OFF. Between the values 6 to 255 the Haze 400 FT produces 

haze.

Examples:

Summary of Contents for Haze 400 FT

Page 1: ...ch Republic www robe cz Show Lighting s r o Czech Republic www robe cz Show Lighting s r o Czech Republic www robe cz Show Lighting s r o Czech Republic www robe cz Show Lighting s r o Czech Republic www robe cz Show Lighting s r o Czech Republic www robe cz ...

Page 2: ......

Page 3: ... Table of contents 1 Introduction 4 2 Cautions 4 3 Unpacking Inspection 4 4 Setup 5 5 Operation 5 6 Remote Control Operation 5 7 DMX Operation 5 8 Technical specifications 6 9 Maintenance and cleaning 6 ...

Page 4: ... or other qualified service personnel For adult use only Hazer must be installed out of the reach of children Never leave the unit running unat tended Never aim the output at open flames Danger of explosion Never add flammable liquids of any kind oil gas perfume to the hazer liquid Pay attention to all warning labels and instructions printed on the exterior of your Haze 400 FT Use only the high qu...

Page 5: ...d you choose do not allow the unit to have more than a 15 degree angle of inclination Important Always monitor tank liquid level during operation Running a hazer with no liquid can permanently damage the unit If you experience low output mechanical noise or no output at all unplug immediately Check liquid level the external fuse remote connection and power from the wall If all of the above appears...

Page 6: ...nk capacity 2 5 Liter Output 2 500 Cu ft Min Dimensions 500 x 320 x 250 mm Weight 18 5 kg 9 Maintenance and cleaning Clean with a dry cloth only Store dry Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges DANGER Disconnect from the mains before starting any maintenance work More complicated maintenance and service operations are only to be carried out...