IP67 

 

 

• E-box Lite 

1 output  

1 Main power Input  

Control: DMX,  W-DMX control, RDM  

Pixel control (1px= 1ft)  

120-277V Input  

Connection via screw terminal blocks, inlets via grommet  

IP67 

 

 

Mounting method 

 

• Via two L-shape brackets 

• LED module “tilt” adjustment range: -95°/+95° 

 

Sizes  

 

 Eminere 1 (300mm / 1ft)

 

 Eminere 2 (600mm / 2ft)

 

 Eminere 3 (900mm / 3ft)

 

• 

Eminere 4 (1200mm / 4ft) 

 

Housing 

 

•  Aluminium extruded body with die-casted end caps 

• Tempered glass 

 

Cooling system 

 

• Convection 

  

Total heat dissipation 

 

• Eminere 1: 61 BTU/h (calculated)  

• Eminere 2: 130 BTU/h (calculated) 

• Eminere 3: 177 BTU/h (calculated) 

• Eminere 4: 228 BTU/h (calculated) 

 

Protection factor 

 

• CE: IP 67 

 

• US: Suitable for wet location  

 

Impact rating 

 

• CE: IK06 

 

Operating ambient temperature range 

 

• -20°C /+40°C (-4°F /+104°F) 

 

 

Operating temperature 

 

• +67°C 

@ A40°C

 (+153°F 

@ A104°F

 

 

Connection 

 

• Input: 

panel connector Amphenol ABAB-DMQ06000021-IN 

 

(P/N13052952)

  

• Output: panel connector Amphenol  ABAB-DAQ06000021 (P/N13052953) + water-tight cap 

Summary of Contents for Anolis Eminere 1

Page 1: ...Version 2 2 ...

Page 2: ...ixture exterior view 4 3 Installation 5 3 1 Mounting the fixture 5 3 2 Connection to mains 5 3 3 The Booster box 9 3 4 The Booster box installation 11 4 Technical specifications 14 5 Cleaning and maintenance 18 5 1 Disposing of the product 19 6 ChangeLog 19 ...

Page 3: ...r installing Make sure the data power cable is not damaged by sharp edges Check the fixture and the power cord from time to time Do not install the unit near an open flame During operation the housing becomes hot Refer servicing to qualified service personnel This fixture falls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protective earthing c...

Page 4: ...higher than 3V m The installation company should check levels of possible interferences above the tested levels E1 E2 E3 given by this standard e g transmitters in surrounding area before installing the equipment Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B Please consider that unauthor...

Page 5: ...onstruction codes and regulations This device falls under class one and must be grounded The Eminere is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 120 277 Volts The following wiring of the input output connectors applies to the fixtures marked X on their labels only Older versions of the Emineres have swapped D and D and do not have mar...

Page 6: ...ct disconnect Emineres to the E box or Booster box and each other when they are under voltage When you change any setting of the E box disconnect the E box from power and connect it to power again to activate changes which you have made Examples of connection for various versions of the E box Please read the E box user manual for more information about its setting and connection to Eminere modules...

Page 7: ...Eminere 7 E box Pro E box Lite ...

Page 8: ...oxes EMINERE 1 Voltage Cable length 120V 190V 230V 277V 10 m 83 131 159 191 20 m 83 131 159 191 30 m 58 131 159 191 50 m 35 88 128 186 70 m 25 63 92 133 100 m 17 44 64 93 200 m 9 22 32 47 EMINERE 2 Voltage Cable length 120V 190V 230V 277V 10 m 41 64 78 94 20 m 41 64 78 94 30 m 28 64 78 94 50 m 17 43 63 91 70 m 12 31 45 65 100 m 9 21 31 46 200 m 4 11 16 23 EMINERE 3 Voltage Cable length 120V 190V 2...

Page 9: ...Star has only one power input 3 3 The Booster box To compensate a voltage drop in large installation the Booster boxes have to be connected in the chain of Emineres at every LED output of the E box The following tables give numbers of Emineres after which the Booster box has to be installed in the chain of Emineres at one LED output of the E box The following tables apply for the Standard mode of ...

Page 10: ...9 18 27 36 45 54 60 72 81 90 21 42 63 84 31 62 93 46 92 200 m 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 11 22 33 44 55 66 77 88 16 32 48 64 80 23 46 69 92 EMINERE 3 Max number of Emineres 3 64 Voltage Cable length 120V 190V 230V 277V 10 m 28 56 44 53 20 m 28 56 44 53 30 m 19 38 57 44 53 50 m 12 24 36 48 60 29 58 43 62 70 m 8 16 24 32 40 48 56 21 42 63 31 62 44 100 m 6 12 1...

Page 11: ... length 70m fixture Eminere 2 The Booster box has to be connected after every 45th Eminere 2 fixture 45 and fixture 90 from 94 fixtures 3 4 The Booster box installation ALWAYS DISCONNECT THE EMINERES FROM MAINS BEFORE CONNECTING DISCONNECTING THE BOOSTER BOX The Booster box falls under protection class I Therefore every Booster box has to be connected to a mains socket outlet with a protective ear...

Page 12: ...331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body Cable gland M20 MS The cable gland M20 MS with a standard seal serves for a cable of diameter of 6 12mm for smaller diameter of cable 4 8mm you have to remove the original seal from the cable gland M20 and use the enclosed reduci...

Page 13: ...Eminere 13 3 Screw the cover 2 back on the Booster box ...

Page 14: ...50 65 100 Bi symetrical 10 x 30 30 x 10 10 x 60 60 x 10 35 x 70 70 x 35 15 x 90 90 x 15 Wallwasher Wide Wallwasher Projected LED Life 60 000 Hrs L70 25 C77F Compatible drivers E box Daisy 1 Output 1 Main power Input Control DMX Art Net sACN W DMX control RDM Pixel control 1px 1ft 120 277V Input Connection via terminal blocks inlets via grommet IP67 E box Star 6 outputs 1 Main power Input Control D...

Page 15: ...extruded body with die casted end caps Tempered glass Cooling system Convection Total heat dissipation Eminere 1 61 BTU h calculated Eminere 2 130 BTU h calculated Eminere 3 177 BTU h calculated Eminere 4 228 BTU h calculated Protection factor CE IP 67 US Suitable for wet location Impact rating CE IK06 Operating ambient temperature range 20 C 40 C 4 F 104 F Operating temperature 67 C Ambient 40 C ...

Page 16: ...Eminere 16 Weight Eminere 1 2 5 kg 5 5 lbs Eminere 2 4 kg 8 82 lbs Eminere 3 6 02 kg 13 27 lbs Eminere 4 7 7 kg 17 lbs Dimensions All dimensions in mm inch ...

Page 17: ...ader Cable FF 2m P N 13053005 Leader Cable FF 5m P N 13053006 Leader Cable FF 10m P N 13053007 Leader Cable FF 25m P N 13053008 Leader Cable FF 50m P N 13053009 US Leader Cables FF Leader Cable FF 2m P N 13053010 Leader Cable FF 5m P N 13053011 Leader Cable FF 10m P N 13053012 Leader Cable FF 25m P N 13053013 ...

Page 18: ... 4 RAL9011 P N 10980491 Cable Cover for Eminere 1 RAL9011 P N 10980484 Cable Cover for Eminere 2 RAL9011 P N 10980485 Cable Cover for Eminere 3 RAL9011 P N 10980486 Cable Cover for Eminere 4 RAL9011 P N 10980487 Mounting Brackets for Eminere 100mm 2pcs RAL9011 P N 10980493 Mounting Brackets for Eminere 200mm 2pcs RAL9006 P N 10980529 Mounting Brackets for Eminere 200mm 2pcs RAL9011 P N 10980494 Mo...

Page 19: ...rmation 1 4 22 04 2020 Technical specifications more specified 1 5 18 05 2020 Wiring of input output connectors changed 1 6 22 06 2020 Voltage range change 1 7 10 09 2020 Booster box seal overview added 1 8 16 12 2020 New dimensions picture 1 9 22 07 2021 New accessories added 2 0 19 08 2021 Jumber cables changed in Optional accessories 2 1 13 10 2021 Technical specifications changed 2 2 26 11 202...