background image

www.

robbe

.com

8

E N G L I S H

USER MANUAL

RO-CONTROL PRO WIFI ESC

M o d e l l s p o r t

 

RO-CONTROL PRO WIFI 2-6S   80 A HV-BEC  Nr.: 8730

RO-CONTROL PRO WIFI 2-6S 100 A HV-BEC  Nr.: 8731

RO-CONTROL PRO WIFI 2-6S 130 A HV-BEC  Nr.: 8732

If you do 

not want 

to select 

any other 

parameter, 

move the 

throttle to 

the zero po-

sition. After 3 

seconds the 

engine emits 

a special 

sound. The 

program-

ming mode 

has been 

exited. You 

can also 

switch off 

the esc 

to exit the 

mode.

Tones 1

2

3

4

5

6

7

8

Para-

meters

1 ♪

2 ♪

3 ♪

4 ♪

1 ♫

1 ♫+

1 ♪

1 ♫+

2 ♪

1 ♫+

3 ♪

1. Brake

off

soft

hard

Very 

hard

2. Battery  

    type

LiPo

NiCd/

NiMH

3. Cut-Off 

    voltage

low

me-

dium

high

4. Timing °

0

3,75

7,5

11,25

15

18,75

22,5

26,25

5. Start 

    mode

nor-

mal

soft

very 

soft

6. Governor

    mode

off

low

high

7. PWM

    frequency

kHz

16 

kHz

24 

kHz

8. BEC out-

put voltage

5 V

6 V

7,4 V

8,4 V

9. Cut-Off 

    mode

re-

duce

cut-

off

10. Battery  

      cells 

auto

2S

3S

4S

5S

6S

11. Rotation 

      direction

nor-

mal

re-

verse

12. ASCF

off

on

13. Reverse

      function

off

on

• the fields highlighted in gray correspond to the factory setting

05. PROGRAMMABLE PARAMETERS

1.   Brake:   [1] off (default), [2] soft, [3] hard, [4] very hard

2.   Battery  type:   [1] LiPo- (default), [2] NiCd / NiMH Zellen

3.   Cut-Off  voltage:   [1] low, [2] medium (default), [3] high 

For nickel batteries: The low / medium / high cut-off voltage is 50 % / 65 % / 75 % of the initial voltage 

of the battery. 

For LiPo batteries: The controller counts the battery cells automatically. The switch-off thresholds have 

the following values: Low (2.8 V) / medium (3.0 V) / high (3.2 V) Example: For 4S / 14.8 V LiPo batteries 

the switch-off threshold is: 11.2 V low / 12.0 V medium / 12.8 V high.

4.   Timing:   1] 0 degrees, [2] 3.75 degrees, [3] 7.5 degrees, [4] 11.25 degrees, [5] 15 degrees (default), [6] 

18.75 degrees, [7] 22.5 degrees, [8] 26.25 degrees 

low timing levels: (0 degrees / 3.75 degrees / 7.5 degrees / 11.25 degrees / 15 degrees / 18.75 de-

grees) for most inrunners 

high timing levels: (22.5 degrees / 26.25 degrees) for 6-pole or multipole outrunners 

Usually: 15 degrees for all outrunner motors. However, to improve efficiency, we recommend setting low 

timing for 2-pole motors (for most inrunner motors) and high timing for 6-pole and multipole motors (for 

most outrunner motors). If you use a high performance motor, you can set a high timing. Some motors 

require special timing. If you are not sure, you should set the timing as recommended by the motor 

manufacturer or 15 degrees. 

Note: After changing the timing, test the drive very carefully before flying.

5.   Start Mode:   Start up with linear acceleration 

[1] Normal: Preferred for fixed-wing models (default).

 

[2] Soft: Preferred for helicopter models, ramp-up from 0 % to 100 % takes 6 seconds. 

[3] Very soft: Preferred for special helicopter models, ramp-up from 0% to 100% takes 12 seconds.

6.   Governor Mode:   [1] off (default), [2] low, [3] high 

When Governor mode is activated, the controller tries to keep the motor at a fixed speed (normally the 

throttle curve is then a horizontal line, you can change the set motor speed by changing the height of 

the curve). 

[1] Off (default) 

[2] Low: Low constant speed mode, 10,000 - 20,000 rpm, for 2-pole motors. 

[3] High: Mode for high constant speed, over 20,000 rpm, for 2-pole motors. 

Note: The governor mode function is automatically deactivated if the throttle setting is below 60%.

7.   PWM frequency:   [1] 8 kHz, [2] 16 kHz (default), [3] 24 kHz 

For motors with a high number of poles and high speed, a higher PWM frequency can make the motor 

run quieter, but at the same time the switching losses become greater and the temperature rise higher.

8.   BEC output voltage:   [1] 5 V (default), [2] 6 V, [3] 7,4 V, [4] 8,4 V 

The high voltages cannot be used for all servos and receivers, the components must be designed for 

this.

9.   Cut-off Mode: 

[1] Reduce power (default): If the battery voltage drops to the set voltage threshold, the controller first 

reduces the motor power and then switches off. 

[2] Switch off: If the battery voltage drops to the set voltage threshold, the controller switches off the 

motor power immediately.

10.  Battery cells:   Only available in LiPo mode[1] Automatic determination of cell count (default), [2] 2S, [3] 

3S, [4] 4S, [5] 5S, [6] 6S 

You can set the options according to your battery pack

11.  Rotation direction: 

[1] Normal (default): The motor rotates in the normal direction. 

[2] Reversed: The direction of rotation of the motor is changed.

12.  Active Switch Continued Flow:   [1] Off (default), [2] On 

The ASCF (Active Switch Continued Flow) technology (higher efficiency) massively reduces the heat 

generation of the controller.

13.  Reverse function [1]Off (default) [2]On : Plug reverse signal wire into an two-stage switch channel on 

the receiver ,to reverse the motor rotation during the flight to decelerate. The lowest point of the pulse 

width range of the 2-stage switch channel must be less than the lowest point of throttle. (e.g. the lowest 

point of throttle is 1000, then the lowest point of pulse width of 2-stage switch channel should be less 

than 1000).  

Effective conditions : 1. Reverse function - on; 2. Governor mode - off; 3. Brake – on (soft).

14.  reset, factory setting: 

If the beep indicates „Restore factory settings“ mode, move the throttle stick to the zero position within 

5 seconds of activating the beep for Reset mode. There is no submenu in this mode. The motor will then 

emit a special beep sequence, meaning that the default settings have been restored.

15.  End: (programming mode terminated) 

When the corresponding beep sounds, move the throttle to the lower position to exit the programming 

mode of the program. The engine will then output a special beep sequence. It indicates that the con-

troller has changed to the normal operating mode.

Summary of Contents for 8730

Page 1: ... um die Motordrehung während des Flugs umzukehren Gassignalkabel Schließen Sie es an den Gaskanal des Empfängers an Die weiße Litze dient zur Übertragung des Signals Über die rote und schwarze Leitung erfolgt der BEC Anschluss für den Empfänger Anschlussleitung WiFi Modul Verbindungskabel zum RO CONTROL PRO WiFi Modul Dadurch wird das Programmieren und das Erkennen von Echtzeitdaten über die ROBBE...

Page 2: ...rameter auswählen Nach der Aktivierung des Programmiermodus hört man Töne die in einer Schleife hintereinander ertönen Die Signale sind jeweils einem bestimmten Parameter zugeordnet Wenn der Motor den Ende Ton emittiert den Gas hebel in die Nullstellung bringen Nach 3 Sek gibt der Motor einen speziellen Ton ab Damit wird das Ver lassen des Program miermodus angezeigt Parameter Tonfolgen 1 Bremse 1...

Page 3: ... niedrig 3 hoch Wenn der Governor Modus aktiviert ist versucht der Regler den Motor auf einer festen Drehzahl zu halten normalerweise ist die Drosselkurve dann eine horizontale Linie Sie können die voreingestellte Motordrehzahl ändern indem Sie die Höhe der Linie ändern 1 Aus Voreinstellung 2 Niedrig Modus für niedrige konstante Geschwindigkeit 10 000 20 000 U min für 2 polige Motoren 3 Hoch Modus...

Page 4: ...den keine Tön abgegeben schlechte Verbindung zwi schen Regler und Akku Verbindungen kontrollieren Polarität über prüfen schlechte Lötstellen schlechter Kontakt Verbindungen neu verlöten zu geringe Akkuspannung Akku überprüfen voll geladenen Akku ver wenden Regler hat ein Problem Regler auswechseln Nach dem Einschalten gibt der Motor Töne für die Anzahl der Zellen aus aber er läuft nicht an Gassteu...

Page 5: ...Funktionsprobe die Servos der Ruder mit der Fernsteuerung in Neutralstellung bringen Knüp pel und Trimmhebel am Sender in Mittelstellung Bitte achten Sie darauf den Gasknüppel in der untersten Stel lung zu belassen damit der Motor nicht anläuft Bei allen Arbeiten an den Teilen der Fernsteuerung des Motors oder des Reglers die Anleitungen beachten die den Geräten beiliegen Ebenso die Anleitungen de...

Page 6: ...nnect it to a two stage receiver switching channel to re verse motor rotation during flight Throttle signal line Connect it to the receiver s throttle channel The white wire is used to trans mit the signal ESC Cont cur rent Burst current BEC Cells Weight Dimensions RO CONTROL PRO WIFI 80A 80 A 100 A 8 4V 7 4V 6V 5V 10A 2 6S 125 g 82 5x39 5x23 5 mm RO CONTROL PRO WIFI 100A 100 A 120 A 8 4V 7 4V 6V ...

Page 7: ... described below Select parameter After activating the programming mode you will hear tones that sound in a loop one after the other The signals are each assigned to a speci fic parameter When the motor emits the end tone move the throttle to the zero position After 3 seconds the motor emits a special tone This will activate the exit from the program ming mode Parameter Tone sequences 1 Brake 1 sh...

Page 8: ...0 to 100 takes 12 seconds 6 Governor Mode 1 off default 2 low 3 high When Governor mode is activated the controller tries to keep the motor at a fixed speed normally the throttle curve is then a horizontal line you can change the set motor speed by changing the height of the curve 1 Off default 2 Low Low constant speed mode 10 000 20 000 rpm for 2 pole motors 3 High Mode for high constant speed ov...

Page 9: ... start no tones are emitted Poor connection between ESC and battery Check connections and polarity bad solder joints bad contact Resolder connections Low input voltage Check battery use fully charged battery ESC might have a problem Change ESC After switching on the motor emits tones for the number of cells but it does not start Throttle stick not calibrated Recalibrate throttle stick After switch...

Page 10: ... Despite existing safety and protective devices of the device damage may occur which is not covered by warranty The warranty also expires if changes are made to the device Important information The receiver system is powered by the built in BEC system of the controller For commissioning always move the throttle stick to the Motor off position and switch on the transmitter Only then connect the bat...