SAFETY

    

 

GENERAL SAFETY 

This  machine  contains  no  user-serviceable  parts.  Roband  Australia,  one  of  our 
agents, or a similarly qualified person(s) should carry out any and all repairs.  Any 
repair person(s) should be instructed to read the Safety warnings within this manual 
before commencing work on these units. 

Steel  cutting  processes  such  as  those  used  in  the  construction  of  this 
machine may result in sharp edges.  Whilst any such edges are removed to 
the best of our ability it is always wise to take care when contacting any edge. 

Particular care should be taken to avoid contact with any steel edge, and warnings 
should  be  given  in  regards  to  the  danger  of  such  contact  to  any  repair  or 
maintenance person(s) prior to commencement of any servicing. 

Do not remove any cover panels that may be on the machine. 

Keep your fingers clear of the louvres on the side of the unit. 

This unit can get 

very

 hot, ensure everyone is aware that the machine is operating 

and take care to avoid contact with hot surfaces.  Use gloves (or some other form 
of protection) when handling the Bain Marie. 

National  Standards  exist  outlining  the  positioning,  spacing  and  ventilation 
requirements  when  installing  new  appliances.    These  Standards  should  be 
consulted  and  new  equipment  should  be  installed  accordingly.    In  any  situation 
where  specifications  allow  a  distance  of  less  than  100mm  we  would  still 
recommend that a well-ventilated air gap of not less than 100mm be maintained.  If 
the machine is near particularly heat-sensitive materials common sense should be 
employed in determining sufficient distancing. 

Always ensure the power cable is not in contact with hot parts of the machine 
when in use. Ensure that any damaged power cord is replaced before further 
use.  These cords should be replaced by qualified service persons only. 

Do not clean this unit with the use of a water jet or spray applicator. 

Keep out of reach of children. 

Electricity  is  dangerous,  and  can  cause  serious  injuries  and  fatalities.  Make 
sure that only qualified people service this machine. 

Never try to move the machine while it is operating or while it is still hot after 
operation. Allow the machine to cool before attempting to move it. 

Never leave an operating machine unattended. 

 

 

Summary of Contents for BM1 Version 3

Page 1: ...x Mxx Alternate Plate Models T Special Features Slim Line Thermometer Ultra Durable Stainless Steel Elements On Off Switch that Electrically Isolates the Unit from Mains Power These instructions cover...

Page 2: ...ithout the written permission of the publisher The material contained within this document is intended entirely for instructional purposes Roband Head Office Sydney Australia Roband Australia Pty Ltd...

Page 3: ...ING 2 COMPLIANCE 2 INSTALLATION 3 OPERATION GENERAL 3 OPERATION MODELS WITH THERMOSTAT CONTROL 4 GENERAL SAFETY 6 CLEANING CARE MAINTENANCE 7 TROUBLESHOOTING 8 SPECIFICATION 8 CIRCUIT DIAGRAMS 9 APPEN...

Page 4: ...ce or knowledge unless they have been given supervision or instruction concerning the safe use of the appliance by a person responsible for their safety These machines are heating units and as with an...

Page 5: ...pt No claims will be accepted or entertained after this period RCM Roband products have been designed and manufactured to comply with any and all specifications set out by the Australian Communication...

Page 6: ...rent Device rated at not less than 30mA for circuit protection when using these units Note that if one RCD is used to protect multiple circuit s with multiple mains outlets the RCD shall be appropriat...

Page 7: ...he energy regulator can be returned to a lower operating value As for dry operation around 2 to 2 should suffice but experience will dictate the best position for the particular food being displayed O...

Page 8: ...BM21T BM4T An operating setting of 75 80 C should suffice and whilst this type of operating results in a longer heat up time running costs will be lower and heating will be more even after the Bain Ma...

Page 9: ...s or some other form of protection when handling the Bain Marie National Standards exist outlining the positioning spacing and ventilation requirements when installing new appliances These Standards s...

Page 10: ...ment This should be removed to prevent any corrosion to the tank and or element failure Although every care is taken during manufacture to remove all sharp edges care should be taken when cleaning to...

Page 11: ...ts have been checked should you call for service SPECIFICATION Constant research and development may necessitate specification changes at any time Nominal Dimensions Model Power Source Power Rating Wi...

Page 12: ...1 BM2 BM21 BM4 NOTE This circuit diagram has been provided for reference and to assist qualified service and repair agents only Under no circumstances should a person not suitably qualified attempt re...

Page 13: ...TS Thermostat NOTE This circuit diagram has been provided for reference and to assist qualified service and repair agents only Under no circumstances should a person not suitably qualified attempt re...

Page 14: ...ve been taken into consideration when an RCD circuit was installed To avoid unwanted tripping due to leakage currents and transient disturbances care should be taken to ensure that the sum of the leak...

Page 15: ...55014 2 1997 Electromagnetic compatibility Requirements for household appliances electric tools and similar apparatus Immunity ENVIRONMENTAL This product is designed in order to contribute as little a...

Page 16: ...Page 13 NOTES This page is intentionally left blank Please note your favourite settings here...

Page 17: ...Page 14 NOTES This page is intentionally left blank Please note your favourite settings here...

Page 18: ...ve goods or materials pursuant to this warranty must be authorized by Roband Australia prior to any action being taken The company reserves the right to reject a claim for warranty if it is not comple...

Page 19: ......

Page 20: ...ER LEADING PRODUCTS AVAILABLE Sycloid Toaster DRINK MIXERS HIGH PERFORMANCE DEEP FRYERS VITAMIX BLENDERS GRILLMAX TOASTERS NOAW Slicers Manufactured Imported in Australia by Authorised Distributor Age...

Reviews: