Robam JZT-B291 Use Manual Download Page 10

8

Gas

 

tap

 

maintenance

These

 

maintenance

 

operations

 

must

 

only

 

be

 

carried

 

out

 

by 

IMPORTANT

Before

 

carrying

 

out

 

any

 

maintenance

 

operations, disconnect

 

the appliance from

 

the

 

gas

and

 

electricity

 

supplies

.

an

 

AUTHORISED

 

PERSON.

If

 

a

 

gas

 

tap

 

becomes

 

stiff

 

to

 

operate

then

 

you

 

should

 

proceed

 

as

 

follows:

Remove

 

the

 

control

 

knobs

pan

 

supports

burners

hob

 

fixing

 

screws

 

and

 

clamps.

Remove

 

the

 

hob

 

from

 

the

 

worktop

 

and

 

remove

 

any

 

underside

 

protective

 

covers.

Disconnect

 

the

 

fixings

 

holding

 

the

 

tap

 

to

 

the

 

fascia

 

panel

 

and

 

separate

 

the

 

assembly

then

 

clean

 

the

 

cone

    and

 

seating

with

 

a

 

cloth

 

dampened

 

with

 

solvent.

Lightly

 

smear

 

the

 

cone

 

with

 

high

 

temperature

 

grease

reassemble

 

into

 

position

 

and

 

rotate

 

a

 

few

 

times.

Remove

 

the

 

cone

 

again

 

and

 

remove

 

any

 

excess

 

grease

making

 

sure

 

that

 

the

 

gas

 

ducts

 

are

 

not

 

obstructed

    with

 

grease.

Gas

 

Hob

Carefully

 

reassemble

 

the

 

components

 

and

 

perform

 

a

 

gas

 

leakage

 

test

If

 

it

 

becomes

 

necessary

 

to

tap

then

 

you

 

should

 

proceed

 

as

 

follows:

Remove

 

the

 

control

 

knobs

pan

 

supports

burners

hob

 

fixing

 

screws

 

and

 

clamps.

Remove

 

the

 

hob

 

from

 

the

 

worktop

 

and

 

remove

 

any

 

underside

 

protective

 

covers.

Disconnect

 

the

 

fixings

 

holding

 

the

 

tap

 

to

 

the

 

fascia

 

panel

 

and

 

separate

 

the

 

assembly.

Disconnect

 

the

 

gas

 

pipe

 

from

 

the

 

gas

 

tap

and

 

then

 

disassemble

 

them

 

from

 

the

 

gas

 

rail

 

by

 

removing

 

the 

    fixing screws.

When

 

fitting

 

a

 

new

 

tap

ensure

 

that

 

a

 

new

 

gasket

 

is

 

used.

Reconnect

 

the

 

gas

 

tap

perform

 

a

 

gas

 

leakage

 

test

 

and

 

then

 

reassemble

 

the

 

hob.

replace

 

a gas 

My appliance isn

'

t

 

working

 

correctly

 

DO

 

NOT

 

ATTEMPT

 

TO

 

REPAIR

 

THE APPLIANCE YOURSELF.

    

The appliance must

 

be

 

accessible

 

for

 

the

 

engineer

 

to

 

perform

 

any

 

necessary

 

repair

If

 

your appliance is 

    installed in

 

such

 

a

 

way

 

that

 

an

 

engineer

 

is

 

concerned

 

that

 

damage

 

will

 

be

 

caused

 

to

 

the appliance or

 

your 

    kitchen

then

 

he will

 

not

 

complete

 

a

 

repair.

This

 

includes

 

situations

 

where appliance have

 

been

 

tiled

 

in

sealed

 

in

 

with

 

sealant

have

 

wooden obstructions

    placed

 

in

 

front

 

of

 

the appliance, like

 

plinths, or

 

any

 

installation

 

other

 

than

 

the

 

one

 

specified

 

by

    ROBAM APPLIANCES

 

CO

.,

LTD.has

 

been

 

completed.

Please

 

refer

 

to

 

the

 

conditions

 

of

 

guarantee

 

that

 

appear

 

on

 

the

 

warranty

 

card

 

that

 

you

 

receive

 

with

 

the appli ance.

IMPORTANT

:ROBAM APPLIANCES

 

CO

.,

LTD.operates

 

a

 

policy

 

of

 

continuous

 

improvement

 

and

 

reserves

    the

 

right

 

to

 

adjust

 

and

 

modify

 

its

 

products

 

without

 

prior

 

notification

.

 

Please

 

note

 

that

 

if

 

an

 

engineer

 

is

 

asked

 

to

 

attend

 

whilst

 

the

 

product

 

is

 

under

 

guarantee

 

and

 

finds

 

that

 

the 

problem is

 

not

 

the

 

result

 

of

 

an appliance fault

then

 

you

 

may

 

be

 

liable

 

for

 

the

 

cost

 

of

 

the

 

call

 

out

 

charge.

Note:

the

 

cook

 

top

 

must

 

be

 

installed

 

with

 

provision

 

to

 

allow

 

the

 

gas

 

to

 

be

 

turned

 

off

 

and disconnected

 

for

 

servicing

 

    

and removal

 

of

 

the

 

appliance

 

as

 

required

 

from

 

gas

 

supply.

The gas pressure must be set by an approved gas fitter and a full operational test and a test forpossible 

    leakages must be carried out by the gas fitter after installation.

The gas pressure must be set by the approved gas fitter as shown on the data plate natural gas 1kPa.

Minimum flow adjustment is no need, because minimum flow has been adjusted when manufacturing.If the 

    minimum flow is not working properly, please contact local dealer to solve the problem.contact information 
    see“After Sale Service”

Summary of Contents for JZT-B291

Page 1: ...JZT B291 Use Manual Gas Hob...

Page 2: ...1 3 9 10 12 12 Installation Instruction Clean And Maintenance Important Safety Information Performance Parameters Operation Methods Common Faults And Solutions Annex 13 After Sale Service 3 Contents...

Page 3: ...domestic foodstuffs ROBAM being near to the appliance and not allowed to touch the appliance at any time During and after use all surfaces will be hot If it is necessary for younger family members to...

Page 4: ...ppliance may call for additional ventilation for example opening of a window or more effective ventilation for example increasing the level of mechanical ventilation where present Care should be used...

Page 5: ...ob improper use or improper installation ROBAM APPLIANCES CO LTD not recommend that this appliance is installed on any type of marine vessel Gas Safety Regulations Building Regulations Building Standa...

Page 6: ...ctly above it 400 mm between the hob surfaces providing that the underside of the horizontal surface is in line with the outer edge of the hob If the underside of the horizontal surface is lower than...

Page 7: ...I E E regulations Ventilation requirements The room containing the hob should have an air supply in accordance with the current edition of AS NZS 5601 The room must have opening windows or equivalent...

Page 8: ...s D The inner must be 10mm and the maximum length 1 2m The gas connection has a Rp 1 2 conical thread Any hose assembly used must be restrained from accidental contact with the flue outlet of an under...

Page 9: ...r rotating the direction or inlet gas pipe Method Paint tenuous and neuter cleaning solution on the connecting part then open the valve If there is air bladder please close the valve and tighten screw...

Page 10: ...TO REPAIR THE APPLIANCE YOURSELF The appliance must be accessible for the engineer to perform any necessary repair If your appliance is installed in such a way that an engineer is concerned that damag...

Page 11: ...knob for 15 seconds after the flame on the burner has lit If after 15s the burner has not lit stop operating the device and open the compartment door and wait at least 1 min before attempting a furthe...

Page 12: ...the stainless steel surfaces of this appliance Remove the pan stands and wipe the Cleaning the hob burners The hob burners should be cleaned once a week or more frequently if they get soiled Remove th...

Page 13: ...eir seats regularlyfor any displacement or deviation and carry out rectification accordingly to put them in place so as to avoid the occurrence of accident The figure is provided for reference only an...

Page 14: ...e and cooper cap are not in place The knob is not pressed to the maximum extend Bending blocking or pressing of hose Air in gas pipe The switch of gas source closes The porcelain head of ignition elec...

Page 15: ...ed personnel Customer Support 13000 ROBAM 76226 Wechat ROBAM_AU Facebook www facebook com robamau Youtube www youtube com c robamau Please quote the model and serial number of your appliance when cont...

Page 16: ...Address No 339 Zhong Xing Road Yuhang Economic Development Zone Yuhang District Hangzhou Edition A 0 Publication Date August 10 2017...

Reviews: