Use
Instruction
Figure 5
Figure 6
8
Plug
in
and
tick
from
the
buzzer
will
indicate
qualified
installation
.
The
hood
is
in
standby
.
3
Lighting
Low
speed
Power
Stir
-
frying
/
High
speed
Press
the
"
power
",
icon
will
flicker
and
range
hood
is
in
standby
state
.
That
is
to
say
,
it
is ready
-
made
and
waiting
for
the
work
instructions
.
When
“
Power
”
icon
is
on
,
if
only
lighting lamp
is
on
,
gently
touch
the
“
Power
”
key
,
the
lighting
lamp
will
be
turned
off
;
if
“
Power
”
is
on and
fan
is
working
,
gently
touch
the
“
Power
”
key
,
the
power
icon
will
flicker
and
range
hood will
be
in
delayed
working
condition
,
then
turn
off
all
the
working
conditions
after
1
min
;
If
power
icon
is
flickering
,
gently
touch
the
“
Power
”
key
,
then all
the
functions
will
be
shut
down
.
Press
the
stir
-
frying
/
High
speed when
"
power
"
is
on
,
stir
-
frying
is
turned
on
,
and
the
icon
shall
be
flickering
.
Press
the
button
again
,
range
hood
shall
change
to
high
speed
.
If
there
is
not
any
operation
in
stir
-
frying
working
condition
,
range
hood
shall
change
to
high
speed
automatically
after
3
minutes
.
The
icon
is
lit
up
in
high
speed
working
condition
.
"
"
Press
the
light
button
to
turn
on
the
light
and
repress
to
turn
it
off
.
Each
press
will
trigger
a
tick
from
the
buzzer
.
The
Lighting
Button
only
controls
the
Press
the
"
Low
speed
when
power
is
on
,
the
impeller
will
rotate
in
low
speed
to
absorb fume
(
that
is
,
low
speed
is
turned
on
).
Press
again
,
low
speed
is
turned
off
.
"
"
"
A825
Switch
Control
Panel
Lighting Low
speed S t i r
-
f r y i n g
/
High speed
Power
Machine body
Check valve
Check valve
interface
St4x18 screw
Seal ring of
check valve
Φ
175ALUM-NOD
Adhesive tape
of air duct
Φ
175Air duct interface
Cut the surplus part smaller than wall hole
Φ
1
8
0
Φ
1
7
0
Φ
1
6
0
Φ
1
5
0
Φ
1
4
0
Adhesive tape
of air duct
Fastener
Slot
The diameter of exhaust wall hole shall be close to the air duct diameter, which shall not be too small,
or it will cause unsmooth fume exhaust, rise of noise and reduction of air volume. Outlet pipe and wall
hole or connection with public flue interface must be sealed strictly so as to make sure that
the
air
duct
and
check
valve
or
public
flue
interface
are
connected
firmly
and
make
sure
that
the
blade
of
check valve
or
public
flue
interface
is
flexible
in
opening
and
closing
.
Note:
Please straighten the ALUM-NOD while assembling so as
to prevent ALUM-NOD from producing noise at semi-stretching
state
;
the
surplus
part
can
be
cut
by
wire
cutter
.
Range Hood