Electrical System Continued
Coach Batteries
The coach batteries in your Roadtrek are either sealed AGM batteries or optional Lithium Battery cells. (If Equipped) Optional EcoTrek Lithium
Battery modules will add additional switches to the bank of switches already in your coach. (Picture 60.1) To turn on your AGM batteries, turn On
the battery disconnect switch on your monitor panel.
To turn your optional lithium battery banks on, press the lower rocker switch upwards towards the On/Off etching on the switch plate. This powers
the battery management system along with the inverter and manages all functions of the system. After turning the module to the On position, if the
blue light does not come on, press the
Reset Rocker Switch
until you hear a click from the battery system. (Approximately five to ten seconds).
In excessive cold or hot temperatures, the battery management system will start the lithium module heater/cooling system until the batteries
reach a temperature where they will accept a charge either from shore power or from the running of the underhood generator.
If all of your batteries have been depleted, start the recharge on one battery module at a time. Allow for a significant charge before starting the
recharge on the other battery modules. Making sure your rocker switch is in the On position, turn off the inverter and start the engine. Allow for
a charge to the battery module and, if needed, press the reset button until you hear a click and the blue light stays illuminated.
If all battery power is not necessary, you can run your coach off of 200, 400, 600AMP hours by turning on only the number of battery modules
needed. * Note – To receive a charge from shore power or the underhood generator, each EcoTrek battery module must be in On position.*
Optional EcoTrek 800AMP Hour Switch Bank.