background image

U S E R M A N UA L – B E D I E N U N G S A N L E I T U N G

RND 320-KA3305P

Summary of Contents for 320-KA3305P

Page 1: ...USER MANUAL BEDIENUNGSANLEITUNG RND 320 KA3305P...

Page 2: ...e RND 320 KA3305P model and when keeping it in storage Read the following before any operation to insure your safety and to keep the best condition for the RND 320 KA3305P model Safety Symbols These s...

Page 3: ...unless you are qualified as service personnel AC Input AC Inut Voltage 230 V 50 Hz Connect the protective grounding conductor of the AC power cord to an earth ground to avoid electrical shock Operati...

Page 4: ...vide the convenient and reliable operation environment They use efficient radiators and low speed stepless speed fan which is quiet and efficiently cooling during operation Furthermore the machine emp...

Page 5: ...RND 320 KA3305P USER MANUAL 5 Front Panel Overview...

Page 6: ...is blinking to switch into the current digit blinking when the current value can be set by adjusting the current adjustment knob Furthmore when the voltage or current digit blinks press the voltage o...

Page 7: ...this time press the button ON OFF and then the output can be turned on or off And the output connection is as shown in the figure 2 THE PARALLEL OPERATION Press and hold the button CH1 for 3 seconds t...

Page 8: ...ed off When the OCP mode is on if the current value on the load or the setting current is more than that in the OCP SET the output will be cut off 5 The Overvoltage Protection OVP Setting and Switchin...

Page 9: ...for 3 seconds and then the front panel will be locked press and hold it again for 3 seconds and then it will be unlocked 7 Beep ON OFF Press and hold the current adjustment knob for 3 seconds and the...

Page 10: ...bit None Data bit 8 Stop bit 1 Data flow control None The Definition of Interface RS232 RND 320 KA3305P POWER SUPPLY Functionality check Run this query command via the terminal application such as MT...

Page 11: ...CK or UNLOCK the front panel Example LOCK1 LOCK the front panel Example LOCK0 UNLOCK the front panel 2 ISET X NR2 Description Sets the output current Example ISET1 2 225 Sets the CH1 output current to...

Page 12: ...ample VOUT1 Returns the CH1 output voltage 8 OUT Boolean Description Turns on or off the output Boolean 0 OFF 1 ON Example OUT1 Turns on the output 9 BEEP Boolean Description Turns on or off the beep...

Page 13: ...number 1 14 TRACK NR1 Description Sets the output of the power supply working on indepent or tracking mode NR1 0 INDEP 1 SER 2 PARA Example TRACK1 15 OCP Boolean Description Stores the panel setting B...

Page 14: ...AGE RANGE CURRENT RANGE SETUP RESOLUTION VOLTAGE RANGE CURRENT RANGE SETUP ACCURACY 25 C 5 C VOLTAGE RANGE CURRENT RANGE RIPPLE 20 20 M VOLTAGE RANGE CURRENT RANGE TEMP COEFFICIENT VOLTAGE RANGE CURRE...

Page 15: ...IMENSIONS MM 252 W 135 H 370 D 9 1KG 100 mS 100 mS 10 Rated load 0 1 0 1 V 0 1 0 1 V 5V 3A 50MV 50MV The proprietary information in this manual is protected by copyrights Any photocopies reproductions...

Page 16: ...16 Sicherheitssymbole Diese Sicherheitssymbole k nnen in diesem Handbuch oder in der Serie erscheinen WARNUNG GEFAHR Hochspannung Earth ground Terminal Deutsch...

Page 17: ...en 21 5 4 Speicher einsetzen 21 5 5 Last an und ausschalten 22 5 6 Bedienelemente blockieren 22 5 7 Quittungston ein ausschalten 22 5 8 Schutzeinrichtungen 22 5 9 Festspannungsauggang 22 5 10 Serien P...

Page 18: ...ersorgung im Bereich bis 2 x 30 VDC und 5 A sowie 5 V 3 A vorgesehen Es d rfen nur Lasten angeschlossen werden die nicht h her sind als dies die maximalen Daten des Netzger tes zulassen Der Einsatz da...

Page 19: ...von defekten Sicherungen stets zuerst den Ausl segrund beseitigen Niemals andere Sicherungen als vorgeschrieben verwenden Ger t nur an einer Steckdose mit Schutzleiter betreiben Sorgen Sie immer f r...

Page 20: ...strombetrieb Konstantspannungsbetrieb Speicher Aktivanzeige Erdungsanschluss Lastanschluss Kanal 1 Lastanschluss Kanal 2 Lastanschluss Kanal 3 Kanalwahl Kanal 1 Kanalwahl Kanal 2 Stromeinstellung Span...

Page 21: ...n Durch Dr cken und Drehen schalten Sie zur n chsten Stelle weiter Dr cken Sie die Kanalwahltaste nochmals jetzt blinkt die Stromanzeige Stellen Sie den Strom mit dem Stromeinsteller ein Durch kurzes...

Page 22: ...3 s bis die OVP SET Anzeige verlischt Dr cken Sie die Taste OVP noch einmal kurz jetzt ist der berspannungsschutz aktiv es leuchtet die zugeh rige Anzeige auf Zum Abschalten des berspannungsschutzes d...

Page 23: ...RA Anzeige leuchtet Jetzt sind beide Kan le parallelgeschaltet wobei Kanal 2 CH2 nun als Master und CH1 als Slave fungiert Alle Einstellungen werden also f r Kanal 2 vorgenommen Kanal 1 folgt diesen S...

Page 24: ...h leicht mit Wasser angefeuchtet sein Keine Reinigungsmittel und Chemikalien einsetzen Muss die Netzsicherung ersetzt werden ist diese nach Ausschalten des Ger tes Abtrennten von Last und Netzkabel ge...

Page 25: ...tellung 10 mV 1 mA Genauigkeit 25 C 5 C Spannung 0 5 20 mV Strom 0 5 10 mA Restwelligkeit 20 Hz 20 MHz Spannung 2 mVrms Strom 3 mArms Temperaturabh ngigkeit Spannung 150 ppm Strom 150 ppm Anzeigeaufl...

Page 26: ...Distrelec Group AG Grabenstrasse 6 CH 8606 N nikon...