15
Danger!
Before connecting or disconnecting cables, verify absence of voltage. Non-observance may lead
to electric shock or machine malfunctions.
•
Use only original fuses with the specified amperage! In the event of faults in power supply switch off the
machine at once!
•
Observe the respective product safety instructions when handling oils, greases and other chemical
substances!
•
Replace damaged spare parts and safety-relevant parts without any delay.
Notice!
Periodical maintenance and inspection of the machine is very important. This avoids malfunctions
and improves safety and reliability in operation.
PARU Mini units or tooling units must be stored in a dry place protected from aggressive media or soiling.
Strong temperature variations must be avoided. After prolonged storage the unit must be cleaned in
accordance with chapter 4.3 of this installation and operating instruction manual.
Disconnect power and compressed air before dismounting the PARU Mini from its target system. Remove all
parts from the system. Loosen the M8 fastening screws. For the rest observe the instructions in chapter 3.1
"Shipping and Handling". We recommend that you keep the cardboard box in which the PARU Mini unit was
delivered in case you should need to return the PARU Mini to Rhein-Nadel Automation GmbH.
The components of the PARU Mini unit are mainly steel and aluminium. Units which are no longer in use
should not be disposed of as complete units but dismantled and the component parts recycled according to
their materials. Please contact Rhein-Nadel Automation GmbH if you want to return the PARU Mini unit.
Spare parts must satisfy the technical requirements specified by us. This is always ensured if genuine spare
parts are used. We assume warranty only for the genuine spare parts supplied by us. The installation and/or
use of spare parts not supplied by us may have a negative effect on design characteristics and thus impair
active and/or passive safety. We do not assume any liability or warranty for damage due to the use of other
than genuine spare parts or accessories.
Please address your spare parts orders to our customer service department.
For a smooth and swift execution of your spare parts order we need following information:
1. Name of customer:
2. Machine identification
3. Designation of spare part required
4. Required quantity
5. Requested mode of shipment
Q
'I have installed the PARU Mini unit in accordance with these installation and operating instructions
but it won’t run.'
A
First, check that:
The controller settings are correct (frequency, amplitude).
The tooling is installed in its original condition and positioned correctly, i.e. no masses have been
removed or added by user.
All threaded fasteners have been selected and tightened in accordance with the Technical Data and
the PARU Mini is fastened properly on a mount of sufficient load bearing capacity.
The correct parts to be conveyed are present and not jammed anywhere.
Movements of the PARU Mini, in particular its useful mass and exciter mass, are not impaired.
The PARU Mini is in horizontal alignment.
5.
Storage, dismantling, disposal
6.
Accessories / spare parts / customer service
7.
Troubleshooting