background image

Rhein - Nadel Automation GmbH 

    3 

   

 

 

    14.04.14 

VT-BA EBC 3000GB 

 

 

1 Technical Data 

 

1.1 Functional description 

 
The  control  unit  EBC  3000  was  developed  to  operate  the  RNA  mini-band  conveyor  FP  15.  The  applied  pulse  width 
modulation generates high efficiency and good start-up characteristics through a near 1 form factor. All operating controls 
including the plug-in device for the motor connection are arranged on the front panel. 
 
A switched-mode power supply in accordance with VDE 0551 generates the operating voltage of max. 24 volts for the belt 
drive, so the motor voltage is a 

contact-safe protective extra-low voltage.

  

 
An  internal  current  scanning  (I  x  R  compensation)  equalizes  speed  fluctuations  when  the  load  on  the  conveyor  belt 
changes.  
 
*  Minimum  and  maximum  output  voltage,  U

min 

und  U

max

,  as  well  as  maximum  motor  current,  I

max

,  are  continuously 

adjustable on the board.  
* The conveyor belt can be powerlessly started and stopped over additional wiring. 
* In addition, one can regulate the target value over an external 0-10V or 0-20mA signal. 
* Over a voltage-free contact, one can reverse the sense of rotation of the connected motor. 
* The control unit is designed for a mains voltage from 110 volts AC to 230VAC. The control unit checks the mains voltage 
and adjusts itself automatically. 
 

1.2 

EC Conformity 

 
The control unit complies with the following regulations: 
 

 

EMC Directive 2014/30/EU  

 

Low Voltage Guideline 2014/35/EU 

 

Applied harmonised standards:

 

 
 

EN 60204, T.1 

 

EN 61439-1 

 

1.3 

Technical data 

 
Power supply 

230V; 

 10%; 50 / 60 Hz 

or 115V; 

 10%; 50/60 Hz 

Primary fuse 

5 x 20; 2A medium time-lag 

Output voltage 

0...28 V DC 

Output current 

0.4...2 A 

External adjustment 

0-10V    0-20mA 

 

 

External release 

over a voltage-free contact 
or 24 V voltage signal  

Case dimensions 

210 x 90 x 150 (H x W x D) 

Interference suppression and resistance to jamming 

conformity in accordance with EMC Directive 

Type of protection 
Ambient temperature 

IP 54 
0...50C° 

2

 

Safety Instructions 

 
The  safety  instructions  must  always  be  read  and  understood.  Observance  of  these  instructions  ensures  that  valuable 
material is maintained and damage to health avoided. 
One  must  make  sure  that  every  person  working  with this  control  unit  is  acquainted  with the  safety  instructions  and  also 
follows them. 
The unit described here is a controller for the operation of RNA belt drives. The limiting values in Technical Data are to be 
observed. 
 
 

Summary of Contents for EBC 3000

Page 1: ...Rhein Nadel Automation GmbH 1 14 04 14 VT BA EBC 3000GB Operating Instructions Control Units for Belt Drives EBC 3000 BA Rhein Nadel Automation GmbH ...

Page 2: ...ction Diagram 6 Declaration of Conformity in terms of the Low Voltage Directive 2014 35 EU and the EMC Directive 2014 30 EU We herewith declare that the product is in conformity with the following provisions Low Voltage Guideline 2014 35 EU EMC Directive 2014 30 EU Applied harmonised standards DIN EN 60204 T1 EN 61439 1 Comments Rhein Nadel Automation Managing Director Jack Grevenstein ...

Page 3: ...nse of rotation of the connected motor The control unit is designed for a mains voltage from 110 volts AC to 230VAC The control unit checks the mains voltage and adjusts itself automatically 1 2 EC Conformity The control unit complies with the following regulations EMC Directive 2014 30 EU Low Voltage Guideline 2014 35 EU Applied harmonised standards EN 60204 T 1 EN 61439 1 1 3 Technical data Powe...

Page 4: ... checked Is the control unit properly closed with all its screws Are the existing plug in fixing devices locked into place screwed tight Are all cables and bushings intact Is the INTENDED USE guaranteed Does the indicated supply voltage on the control unit conform with the local power supply network The control unit may only be put into operation if all above questions can clearly be answered with...

Page 5: ...n from the mains in the Start Stop mode the control unit is to be opened by observing the above mentioned safety notes The blind plug at the side of the case replaces a screw fitting with strain relief size M16 This is where the cable for the release is lead through There are two possible ways of performing a release Release through a contact The way this simple and economical solution works is th...

Page 6: ...Rhein Nadel Automation GmbH 6 14 04 14 VT BA EBC 3000GB 4 Dimensioned Drawing 5 Connection Diagram ...

Page 7: ...ch Hall Tel 49 0 791 9460098 0 Fax 49 0 791 9460098 29 Email info psa zt de HSH Handling Systems AG Wangenstr 96 CH 3360 Herzogenbuchsee Tel 41 062 95610 00 Fax 41 062 95610 10 Internet www rna de Email info handling systems ch RNA AUTOMATION LTD Hayward Industrial Park Tameside Drive Castle Bromwich GB Birmingham B 35 7 AG Tel 44 0121 749 2566 Fax 44 0121 749 6217 Internet www rna uk com Email rn...

Reviews: