Rhein - Nadel Automation GmbH
3
14.04.14
VT-BA EBC 3000GB
1 Technical Data
1.1 Functional description
The control unit EBC 3000 was developed to operate the RNA mini-band conveyor FP 15. The applied pulse width
modulation generates high efficiency and good start-up characteristics through a near 1 form factor. All operating controls
including the plug-in device for the motor connection are arranged on the front panel.
A switched-mode power supply in accordance with VDE 0551 generates the operating voltage of max. 24 volts for the belt
drive, so the motor voltage is a
contact-safe protective extra-low voltage.
An internal current scanning (I x R compensation) equalizes speed fluctuations when the load on the conveyor belt
changes.
* Minimum and maximum output voltage, U
min
und U
max
, as well as maximum motor current, I
max
, are continuously
adjustable on the board.
* The conveyor belt can be powerlessly started and stopped over additional wiring.
* In addition, one can regulate the target value over an external 0-10V or 0-20mA signal.
* Over a voltage-free contact, one can reverse the sense of rotation of the connected motor.
* The control unit is designed for a mains voltage from 110 volts AC to 230VAC. The control unit checks the mains voltage
and adjusts itself automatically.
1.2
EC Conformity
The control unit complies with the following regulations:
EMC Directive 2014/30/EU
Low Voltage Guideline 2014/35/EU
Applied harmonised standards:
EN 60204, T.1
EN 61439-1
1.3
Technical data
Power supply
230V;
10%; 50 / 60 Hz
or 115V;
10%; 50/60 Hz
Primary fuse
5 x 20; 2A medium time-lag
Output voltage
0...28 V DC
Output current
0.4...2 A
External adjustment
0-10V 0-20mA
External release
over a voltage-free contact
or 24 V voltage signal
Case dimensions
210 x 90 x 150 (H x W x D)
Interference suppression and resistance to jamming
conformity in accordance with EMC Directive
Type of protection
Ambient temperature
IP 54
0...50C°
2
Safety Instructions
The safety instructions must always be read and understood. Observance of these instructions ensures that valuable
material is maintained and damage to health avoided.
One must make sure that every person working with this control unit is acquainted with the safety instructions and also
follows them.
The unit described here is a controller for the operation of RNA belt drives. The limiting values in Technical Data are to be
observed.